Pure component selectivity analysis of multivariate calibration models from near-infrared spectra

被引:36
|
作者
Arnold, MA [1 ]
Small, GW
Xiang, D
Qui, J
Murhammer, DW
机构
[1] Univ Iowa, Opt Sci & Technol Ctr, Iowa City, IA 52242 USA
[2] Univ Iowa, Dept Chem, Iowa City, IA 52242 USA
[3] Univ Iowa, Dept Chem & Biochem Engn, Iowa City, IA 52242 USA
[4] Ohio Univ, Ctr Intelligent Chem Insttumentat, Athens, OH 45701 USA
[5] Ohio Univ, Dept Chem & Biochem, Clippinger Labs, Athens, OH 45701 USA
关键词
D O I
10.1021/ac035516q
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A novel procedure is proposed as a method to characterize the chemical basis of selectivity for multivariate calibration models. This procedure involves submitting pure component spectra of both the target analyte and suspected interferences to the calibration model in question. The resulting model output is analyzed and interpreted in terms of the relative contribution of each component to the predicted analyte concentration. The utility of this method is illustrated by an analysis of calibration models for glucose, sucrose, and maltose. Near-infrared spectra are collected over the 5000-4000-cm(-1) spectral range for a set of ternary mixtures of these sugars. Partial least-squares (PLS) calibration models are generated for each component, and these models provide selective responses for the targeted analytes with standard errors of prediction ranging from 0.2 to 0.7 mM over the concentration range of 0.5-50 mM. The concept of the proposed pure component selectivity analysis is illustrated with these models. Results indicate that the net analyte signal is solely responsible for the selectivity of each individual model. Despite strong spectral overlap for these simple carbohydrates, calibration models based on the PLS algorithm provide sufficient selectivity to distinguish these commonly used sugars. The proposed procedure demonstrates conclusively that no component of the sucrose or maltose spectrum contributes to the selective measurement of glucose. Analogous conclusions are possible for the sucrose and maltose calibration models.
引用
收藏
页码:2583 / 2590
页数:8
相关论文
共 50 条
  • [1] Matrix-enhanced calibration procedure for multivariate calibration models with near-infrared spectra
    Riley, MR
    Arnold, MA
    Murhammer, DW
    APPLIED SPECTROSCOPY, 1998, 52 (10) : 1339 - 1347
  • [2] Multivariate calibration models based on the direct analysis of near-infrared single-beam spectra
    Lu, G
    Zhou, XJ
    Arnold, MA
    Small, GW
    APPLIED SPECTROSCOPY, 1997, 51 (09) : 1330 - 1339
  • [3] Comparison of multivariate calibration models for glucose, urea, and lactate from near-infrared and Raman spectra
    Min Ren
    Mark A. Arnold
    Analytical and Bioanalytical Chemistry, 2007, 387 : 879 - 888
  • [4] Comparison of multivariate calibration models for glucose, urea, and lactate from near-infrared and Raman spectra
    Ren, Min
    Arnold, Mark A.
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2007, 387 (03) : 879 - 888
  • [5] Multivariate calibration models for lysozyme from near-infrared transmission spectra in scattering solutions of monodisperse microspheres
    Green, CE
    Wiencek, JM
    Arnold, MA
    ANALYTICAL CHEMISTRY, 2002, 74 (14) : 3392 - 3399
  • [6] Ensemble preprocessing of near-infrared (NIR) spectra for multivariate calibration
    Xu, Lu
    Zhou, Yan-Ping
    Tang, Li-Juan
    Wu, Hai-Long
    Jiang, Jian-Hui
    Shen, Guo-Li
    Yu, Ru-Qin
    ANALYTICA CHIMICA ACTA, 2008, 616 (02) : 138 - 143
  • [7] Multivariate calibration of near-infrared spectra by using influential variables
    Shao, Xueguang
    Zhang, Min
    Cai, Wensheng
    ANALYTICAL METHODS, 2012, 4 (02) : 467 - 473
  • [8] Spectral Encoder to Extract the Features of Near-Infrared Spectra for Multivariate Calibration
    Duan, Chaoshu
    Liu, Xuyang
    Cai, Wensheng
    Shao, Xueguang
    JOURNAL OF CHEMICAL INFORMATION AND MODELING, 2022, 62 (16) : 3695 - 3703
  • [9] A dual model strategy to transfer multivariate calibration models for near-infrared spectral analysis
    Wang, Jiajun
    Li, Zhengfeng
    Wang, Yi
    Liu, Yan
    Cai, Wensheng
    Shao, Xueguang
    SPECTROSCOPY LETTERS, 2016, 49 (05) : 348 - 354
  • [10] Wavelength calibration of near-infrared spectra
    Hinkle, KH
    Joyce, RR
    Hedden, A
    Wallace, L
    Engleman, R
    PUBLICATIONS OF THE ASTRONOMICAL SOCIETY OF THE PACIFIC, 2001, 113 (783) : 548 - 566