Detection of Parathyroid Autofluorescence Using Near-Infrared Imaging: A Multicenter Analysis of Concordance Between Different Surgeons

被引:107
作者
Kahramangil, Bora [1 ]
Dip, Fernando [2 ,3 ]
Benmiloud, Fares [4 ]
Falco, Jorge [2 ]
de La Fuente, Martin [2 ]
Verna, Silvina [2 ]
Rosenthal, Raul [3 ]
Berber, Eren [1 ]
机构
[1] Cleveland Clin, Dept Endocrine Surg, Cleveland, OH 44106 USA
[2] IADT, Buenos Aires, DF, Argentina
[3] Cleveland Clin Florida, Dept Surg, Weston, FL 33331 USA
[4] Hop Europeen, Dept Endocrine Surg, Marseille, France
关键词
GAMMA-PROBE IDENTIFICATION; CENTRAL NECK-SURGERY; THYROID-SURGERY; GLANDS; HYPERPARATHYROIDISM; PRESERVATION; FLUORESCENCE; SPECTROSCOPY; UTILITY;
D O I
10.1245/s10434-018-6364-2
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Parathyroid glands (PGs) exhibit autofluorescence (AF) when excited by near-infrared laser. This multicenter study aims to analyze how this imaging could facilitate the detection of PGs during thyroidectomy and parathyroidectomy procedures. This was a retrospective Institutional Review Board-approved analysis of prospectively collected data at three centers. Near-infrared fluorescence imaging (NIFI) was used to detect AF from PGs during thyroidectomy and parathyroidectomy procedures. Logistic regression analysis was performed to assess the utility of NIFI to identify PGs and concordance at these centers. Overall, 210 patients underwent total thyroidectomy (n = 95), thyroid lobectomy (n = 41), and parathyroidectomy (n = 74) (n = 70 per center). Using NIFI, AF was detected from 98% of visually identified PGs. Upon initial exploration, 46% of PGs were not visible to the naked eye due to coverage by soft tissue, but AF from these glands could be detected by NIFI without any further dissection. Overall, a median of one PG per patient was detected by NIFI in this fashion before being identified visually (p = nonsignificant between centers). On logistic regression, smaller PGs were more likely to be missed visually, but localized by AF on NIFI (odds ratio with increasing size, 0.91; p = 0.02). In our experience, NIFI facilitated PG identification by detecting their AF, before conventional recognition by the surgeon, in 37-67% of the time. Despite the variability in this rate across centers, there was a concordance in detecting AF from 97 to 99% of the PGs using NIFI. We suggest the incorporation of AF on NIFI alongside conventional visual cues to aid identification of PGs during neck operations.
引用
收藏
页码:957 / 962
页数:6
相关论文
共 16 条
[1]  
Allo M, 2008, AM J SURG, V196, P935
[2]   Impact of autofluorescence-based identification of parathyroids during total thyroidectomy on postoperative hypocalcemia: a before and after controlled study [J].
Benmiloud, Fares ;
Rebaudet, Stanislas ;
Varoquaux, Arthur ;
Penaranda, Guillaume ;
Bannier, Marie ;
Denizot, Anne .
SURGERY, 2018, 163 (01) :23-29
[3]   Raman spectroscopy of parathyroid tissue pathology [J].
Das, Kaustuv ;
Stone, Nicholas ;
Kendall, Catherine ;
Fowler, Clare ;
Christie-Brown, J. .
LASERS IN MEDICAL SCIENCE, 2006, 21 (04) :192-197
[4]   Intraoperative Near-infrared Imaging for Parathyroid Gland Identification by Auto-fluorescence: A Feasibility Study [J].
De Leeuw, Frederic ;
Breuskin, Ingrid ;
Abbaci, Muriel ;
Casiraghi, Odile ;
Mirghani, Haitham ;
Ben Lakhdar, Aicha ;
Laplace-Builhe, Corinne ;
Hartl, Dana .
WORLD JOURNAL OF SURGERY, 2016, 40 (09) :2131-2138
[5]   METHYLENE BLUE FOR RAPID IDENTIFICATION OF PARATHYROIDS [J].
DUDLEY, NE .
BRITISH MEDICAL JOURNAL, 1971, 3 (5776) :680-&
[6]   Increased identification of parathyroid glands using near infrared light during thyroid and parathyroid surgery [J].
Falco, Jorge ;
Dip, Fernando ;
Quadri, Pablo ;
de la Fuente, Martin ;
Prunello, Marcos ;
Rosenthal, Raul J. .
SURGICAL ENDOSCOPY AND OTHER INTERVENTIONAL TECHNIQUES, 2017, 31 (09) :3737-3742
[7]   Cutting Edge in Thyroid Surgery: Autofluorescence of Parathyroid Glands [J].
Falco, Jorge ;
Dip, Fernando ;
Quadri, Pablo ;
de la Fuente, Martin ;
Rosenthal, Raul .
JOURNAL OF THE AMERICAN COLLEGE OF SURGEONS, 2016, 223 (02) :374-380
[8]   Inadvertent parathyroidectomy during thyroid surgery: the incidence of a complication of thyroidectomy [J].
Gourgiotis, Stavros ;
Moustafellos, Panagiotis ;
Dimopoulos, Nikitas ;
Papaxoinis, George ;
Baratsis, Sotirios ;
Hadjiyannakis, Evangelos .
LANGENBECKS ARCHIVES OF SURGERY, 2006, 391 (06) :557-560
[9]   Gamma probe identification of normal parathyroid glands during central neck surgery can facilitate parathyroid preservation [J].
Grubbs, Elizabeth G. ;
Mittendorf, Elizabeth A. ;
Perrier, Nancy D. ;
Lee, Jeffrey E. .
AMERICAN JOURNAL OF SURGERY, 2008, 196 (06) :931-935
[10]   The use of near-infrared fluorescence imaging in endocrine surgical procedures [J].
Kahramangil, Bora ;
Berber, Eren .
JOURNAL OF SURGICAL ONCOLOGY, 2017, 115 (07) :848-855