Intra- and inter-examination repeatability of magnetic resonance spectroscopy, magnitude-based MRI, and complex-based MRI for estimation of hepatic proton density fat fraction in overweight and obese children and adults

被引:58
作者
Tyagi, Avishkar [1 ]
Yeganeh, Omid [1 ]
Levin, Yakir [1 ]
Hooker, Jonathan C. [1 ]
Hamilton, Gavin C. [1 ]
Wolfson, Tanya [2 ]
Gamst, Anthony [2 ]
Zand, Amir K. [1 ]
Heba, Elhamy [1 ]
Loomba, Rohit [3 ,4 ]
Schwimmer, Jeffrey [1 ,5 ,6 ]
Middleton, Michael S. [1 ]
Sirlin, Claude B. [1 ]
机构
[1] Univ Calif San Diego, Dept Radiol, Liver Imaging Grp, MR3T Bydder Lab, San Diego, CA 92103 USA
[2] Univ Calif San Diego, SDSC, CASL, La Jolla, CA 92093 USA
[3] Univ Calif San Diego, Dept Med, Div Gastroenterol, La Jolla, CA 92093 USA
[4] Univ Calif San Diego, Dept Family Med & Prevent Med, Div Epidemiol, La Jolla, CA 92093 USA
[5] Univ Calif San Diego, Dept Pediat Hepatol & Nutr, Div Pediat Gastroenterol, San Diego, CA 92103 USA
[6] Rady Childrens Hosp, Dept Gastroenterol, San Diego, CA USA
来源
ABDOMINAL IMAGING | 2015年 / 40卷 / 08期
基金
美国国家卫生研究院;
关键词
Proton density fat fraction; PDFF; Hepatic steatosis; Obesity; Intra-examination repeatability; Inter-examination repeatability; Magnitude-based MRI; Complex-based MRI; Magnetic resonance spectroscopy; Quantitative imaging biomarkers; LIVER FAT; QUANTITATIVE ASSESSMENT; FLIP-ANGLE; QUANTIFICATION; STEATOSIS; ACCURATE; DISEASE; REPRODUCIBILITY; SEPARATION; HISTOLOGY;
D O I
10.1007/s00261-015-0542-5
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
Determine intra- and inter-examination repeatability of magnitude-based magnetic resonance imaging (MRI-M), complex-based magnetic resonance imaging (MRI-C), and magnetic resonance spectroscopy (MRS) at 3T for estimating hepatic proton density fat fraction (PDFF), and using MRS as a reference, confirm MRI-M and MRI-C accuracy. Twenty-nine overweight and obese pediatric (n = 20) and adult (n = 9) subjects (23 male, 6 female) underwent three same-day 3T MR examinations. In each examination MRI-M, MRI-C, and single-voxel MRS were acquired three times. For each MRI acquisition, hepatic PDFF was estimated at the MRS voxel location. Intra- and inter-examination repeatability were assessed by computing standard deviations (SDs) and intra-class correlation coefficients (ICCs). Aggregate SD was computed for each method as the square root of the average of first repeat variances. MRI-M and MRI-C PDFF estimation accuracy was assessed using linear regression with MRS as a reference. For MRI-M, MRI-C, and MRS acquisitions, respectively, mean intra-examination SDs were 0.25%, 0.42%, and 0.49%; mean intra-examination ICCs were 0.999, 0.997, and 0.995; mean inter-examination SDs were 0.42%, 0.45%, and 0.46%; and inter-examination ICCs were 0.995, 0.992, and 0.990. Aggregate SD for each method was < 0.9%. Using MRS as a reference, regression slope, intercept, average bias, and R (2), respectively, for MRI-M were 0.99%, 1.73%, 1.61%, and 0.986, and for MRI-C were 0.96%, 0.43%, 0.40%, and 0.991. MRI-M, MRI-C, and MRS showed high intra- and inter-examination hepatic PDFF estimation repeatability in overweight and obese subjects. Longitudinal hepatic PDFF change > 1.8% (twice the maximum aggregate SD) may represent real change rather than measurement imprecision. Further research is needed to assess whether examinations performed on different days or with different MR technologists affect repeatability of MRS voxel placement and MRS-based PDFF measurements.
引用
收藏
页码:3070 / 3077
页数:8
相关论文
共 30 条
[1]   Reproducibility of MR-based liver fat quantification across field strength: Same-day comparison between 1.5T and 3T in obese subjects [J].
Artz, Nathan S. ;
Haufe, William M. ;
Hooker, Catherine A. ;
Hamilton, Gavin ;
Wolfson, Tanya ;
Campos, Guilherme M. ;
Gamst, Anthony C. ;
Schwimmer, Jeffrey B. ;
Sirlin, Claude B. ;
Reeder, Scott B. .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2015, 42 (03) :811-817
[2]   Magnetic resonance for quantitative assessment of liver steatosis: a new potential tool to monitor antiretroviral-drug-related toxicities [J].
Guaraldi, Giovanni ;
Besutti, Giulia ;
Stentarelli, Chiara ;
Zona, Stefano ;
Nocetti, Luca ;
Loria, Paola ;
Ballestri, Stefano ;
Losi, Luisa ;
Torricelli, Pietro ;
Ligabue, Guido .
ANTIVIRAL THERAPY, 2012, 17 (06) :965-971
[3]   In vivo characterization of the liver fat 1H MR spectrum [J].
Hamilton, Gavin ;
Yokoo, Takeshi ;
Bydder, Mark ;
Cruite, Irene ;
Schroeder, Michael E. ;
Sirlin, Claude B. ;
Middleton, Michael S. .
NMR IN BIOMEDICINE, 2011, 24 (07) :784-790
[4]   Effect of PRESS and STEAM Sequences on Magnetic Resonance Spectroscopic Liver Fat Quantification [J].
Hamilton, Gavin ;
Middleton, Michael S. ;
Bydder, Mark ;
Yokoo, Takeshi ;
Schwimmer, Jeffrey B. ;
Kono, Yuko ;
Patton, Heather M. ;
Lavine, Joel E. ;
Sirlin, Claude B. .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2009, 30 (01) :145-152
[5]   Addressing phase errors in fat-water imaging using a mixed magnitude/complex fitting method [J].
Hernando, D. ;
Hines, C. D. G. ;
Yu, H. ;
Reeder, S. B. .
MAGNETIC RESONANCE IN MEDICINE, 2012, 67 (03) :638-644
[6]   T1 Independent, T2* Corrected Chemical Shift Based Fat-Water Separation With Multi-peak Fat Spectral Modeling Is an Accurate and Precise Measure of Hepatic Steatosis [J].
Hines, Catherine D. G. ;
Frydrychowicz, Alex ;
Hamilton, Gavin ;
Tudorascu, Dana L. ;
Vigen, Karl K. ;
Yu, Huanzhou ;
McKenzie, Charles A. ;
Sirlin, Claude B. ;
Brittain, Jean H. ;
Reeder, Scott B. .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2011, 33 (04) :873-881
[7]   Effect of Flip Angle on the Accuracy and Repeatability of Hepatic Proton Density Fat Fraction Estimation by Complex Data-Based, T1-Independent, T2*-Corrected, Spectrum-Modeled MRI [J].
Johnson, Benjamin L. ;
Schroeder, Michael E. ;
Wolfson, Tanya ;
Gamst, Anthony C. ;
Hamilton, Gavin ;
Shiehmorteza, Masoud ;
Loomba, Rohit ;
Schwimmer, Jeffrey B. ;
Reeder, Scott ;
Middleton, Michael S. ;
Sirlin, Claude B. .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2014, 39 (02) :440-447
[8]   Noninvasive assessment of hepatic lipid composition: Advancing understanding and management of fatty liver disorders [J].
Johnson, Nathan A. ;
Walton, David W. ;
Sachinwalla, Toos ;
Thompson, Campbell H. ;
Smith, Kate ;
Ruell, Patricia A. ;
Stannard, Stephen R. ;
George, Jacob .
HEPATOLOGY, 2008, 47 (05) :1513-1523
[9]   Reproducibility of MRI-Determined Proton Density Fat Fraction Across Two Different MR Scanner Platforms [J].
Kang, Geraldine H. ;
Cruite, Irene ;
Shiehmorteza, Masoud ;
Wolfson, Tanya ;
Gamst, Anthony C. ;
Hamilton, Gavin ;
Bydder, Mark ;
Middleton, Michael S. ;
Sirlin, Claude B. .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2011, 34 (04) :928-934
[10]   Quantitative Chemical Shift-Encoded MRI Is an Accurate Method to Quantify Hepatic Steatosis [J].
Kuehn, Jens-Peter ;
Hernando, Diego ;
Mensel, Birger ;
Krueger, Paul C. ;
Ittermann, Till ;
Mayerle, Julia ;
Hosten, Norbert ;
Reeder, Scott B. .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2014, 39 (06) :1494-1501