Vitamin D metabolite profiling using liquid chromatography-tandem mass spectrometry (LC-MS/MS)

被引:45
|
作者
Jones, Glenville [1 ]
Kaufmann, Martin [1 ]
机构
[1] Queens Univ, Dept Biomed & Mol Sci, Botterell Hall,Room 650, Kingston, ON K7L 3N6, Canada
基金
加拿大健康研究院;
关键词
Metabolomics; 25-OH-D-3; Vitamin D assay; LC-MS/MS; DMEQ-TAD; PROTEIN-BINDING RADIOASSAY; 24,25-DIHYDROXYVITAMIN D; 25-HYDROXYVITAMIN D; HUMAN-PLASMA; CYP24A1; SERUM; DERIVATIZATION; MUTATION; INFANTS; ASSAY;
D O I
10.1016/j.jsbmb.2015.09.026
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
Liquid chromatography tandem mass spectrometry (LC-MS/MS) has emerged as the latest technology to be used to assay the metabolites of vitamin D. The method uses molecular mass as a detection technique after straightforward extraction and chromatography steps. LC-MS/MS assay provides a level of accuracy and reproducibility not seen before with other methods and is beginning to rival antibody-based methods in terms of sensitivity and convenience. Methods for detection of underivatized and DMEQ-TAD derivatized vitamin D metabolites are evaluated. Sensitivity is improved by 10-100 fold with derivatization and allows for the simultaneous assay of multiple vitamin D metabolites, a process termed vitamin D metabolite profiling. Clinical and research applications of vitamin D metabolite profiling are discussed. Published by Elsevier Ltd.
引用
收藏
页码:110 / 114
页数:5
相关论文
共 50 条
  • [11] A rapid and sensitive liquid chromatography-tandem mass spectrometry (LC-MS/MS) method for the estimation of amlodipine in human plasma
    Bhatt, Jignesh
    Singh, Sadhana
    Subbaiah, Gunta
    Shah, Bhavin
    Kambli, Sandeep
    Ameta, Suresh
    BIOMEDICAL CHROMATOGRAPHY, 2007, 21 (02) : 169 - 175
  • [12] Identification and quantification of the atypical metabolite ornithine-lactam in human plasma by liquid chromatography-tandem mass spectrometry (LC-MS/MS)
    Martens-Lobenhoffer, Jens
    Becker, Achim
    Freude, Horst
    Bode-Boeger, Stefanie M.
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2009, 877 (23): : 2284 - 2289
  • [13] Novel liquid chromatography tandem mass spectrometry (LC-MS/MS) methods for measuring steroids
    Keevil, Brian G.
    BEST PRACTICE & RESEARCH CLINICAL ENDOCRINOLOGY & METABOLISM, 2013, 27 (05) : 663 - 674
  • [14] Analysis of methoxyfenozide residues in fruits, vegetables, and mint by liquid chromatography-tandem mass spectrometry (LC-MS/MS)
    Hall, GL
    Engebretson, J
    Hengel, MJ
    Shibamoto, T
    JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 2004, 52 (04) : 672 - 676
  • [15] Naturally-occurring folates in foods: Method development and analysis using liquid chromatography-tandem mass spectrometry (LC-MS/MS)
    Vishnumohan, Shyamala
    Arcot, Jayashree
    Pickford, Russell
    FOOD CHEMISTRY, 2011, 125 (02) : 736 - 742
  • [16] Determination of Fusarium Mycotoxin Beauvericin in Bombyx batryticatus by Liquid Chromatography-Tandem Mass Spectrometry (LC-MS/MS)
    Jiang, X.
    Chen, Y. J.
    Shi, L. G.
    ASIAN JOURNAL OF CHEMISTRY, 2013, 25 (12) : 6693 - 6696
  • [17] Development and validation of a liquid chromatography-tandem mass spectrometry (LC-MS/MS) method for the quantification of tigecycline in rat brain tissues
    Munyeza, Chiedza F.
    Shobo, Adeola
    Baijnath, Sooraj
    Bratkowska, Dominika
    Naiker, Suhashni
    Bester, Linda A.
    Singh, Sanil D.
    Maguire, Glenn E. M.
    Kruger, Hendrik G.
    Naicker, Tricia
    Govender, Thavendran
    BIOMEDICAL CHROMATOGRAPHY, 2016, 30 (06) : 837 - 845
  • [18] Measurement of oxidative stress parameters using liquid chromatography-tandem mass spectroscopy (LC-MS/MS)
    Winnik, Witold M.
    Kitchin, Kirk T.
    TOXICOLOGY AND APPLIED PHARMACOLOGY, 2008, 233 (01) : 100 - 106
  • [19] DETERMINATION OF CLONAZEPAM IN HAIR AND NAIL USING LIQUID CHROMATOGRAPHY TANDEM MASS SPECTROMETRY (LC-MS/MS)
    John, Cijo
    Ghosh, Priyankar
    Varshney, K. M.
    Kaur, Sukhminder
    Shukla, S. K.
    Satyanarayana, S.
    JOURNAL OF LIQUID CHROMATOGRAPHY & RELATED TECHNOLOGIES, 2014, 37 (14) : 1917 - 1928
  • [20] Methodological approach to the intracrine study and estimation of DHEA and DHEA-S using liquid chromatography-tandem mass spectrometry (LC-MS/MS)
    Shibata, Yasuhiro
    Arai, Seiji
    Honma, Seijiro
    JOURNAL OF STEROID BIOCHEMISTRY AND MOLECULAR BIOLOGY, 2015, 145 : 193 - 199