Comparison of the analytical sensitivity of seven commonly used commercial SARS-CoV-2 automated molecular assays

被引:63
作者
Mostafa, Heba H. [1 ]
Hardick, Justin [2 ,3 ]
Morehead, Elizabeth [1 ]
Miller, Jo-Anne [1 ]
Gaydos, Charlotte A. [2 ,3 ]
Manabe, Yukari C. [3 ]
机构
[1] Johns Hopkins Univ, Sch Med, Dept Pathol, Div Med Microbiol, Baltimore, MD 21287 USA
[2] Johns Hopkins Univ, Sch Med, Dept Emergency Med, Baltimore, MD 21287 USA
[3] Johns Hopkins Univ, Sch Med, Dept Med, Div Infect Dis, Baltimore, MD 21287 USA
关键词
SARS-CoV-2; COVID-19; LOD;
D O I
10.1016/j.jcv.2020.104578
中图分类号
Q93 [微生物学];
学科分类号
071005 ; 100705 ;
摘要
The SARS-CoV-2 pandemic has challenged molecular microbiology laboratories to quickly implement and validate diagnostic assays and to expand testing capacity in a short timeframe. Multiple molecular diagnostic methods received FDA emergency use authorization (EUA) and were promptly validated for use nationwide. Several studies reported the analytical and/ or clinical evaluation of these molecular assays, however differences in the viral materials used for these evaluations complicated direct comparison of their analytical performance. In this study, we compared the analytical sensitivity (lower limit of detection, LOD) of seven commonly used qualitative SARS-CoV-2 molecular assays: the Abbott Molecular RealTime SARS-CoV-2 assay, the NeuMoDx (TM) SARS-CoV-2 assay, the Roche Cobas (R) SARS-CoV-2 assay, the BD SARS-CoV-2 reagents for BD MAX (TM) system, the Hologic Aptima (R) SARS-CoV-2 assay, the Xpert Xpress SARS-CoV-2 test, and the GenMark ePlex SARS-CoV-2 test. The comparison was performed utilizing a single positive clinical specimen that was serially diluted in viral transport media and quantified by the EUA approved SARS-CoV-2 droplet digital PCR (ddPCR) assay. Replicate samples were prepared and evaluated for reproducibility across different molecular assays with multiple replicates per assay. Our data demonstrated that the seven assays could detect 100 % of replicates at a nucleocapsid gene concentration of (N1 = 1,267 and N2 = 1,392) copies/mL. At a one log less concentration, the Abbott, the Roche, and the Xpert Xpress assays detected 100 % of the tested replicates.
引用
收藏
页数:4
相关论文
共 42 条
  • [1] Aea Basu, 2020, PERFORMANCE RAPID NU, DOI [10.1101/2020.05.11.089896v1., DOI 10.1101/2020.05.11.089896V1]
  • [2] Presymptomatic SARS-CoV-2 Infections and Transmission in a Skilled Nursing Facility
    Arons, M. M.
    Hatfield, K. M.
    Reddy, S. C.
    Kimball, A.
    James, A.
    Jacobs, J. R.
    Taylor, J.
    Spicer, K.
    Bardossy, A. C.
    Oakley, L. P.
    Tanwar, S.
    Dyal, J. W.
    Harney, J.
    Chisty, Z.
    Bell, J. M.
    Methner, M.
    Paul, P.
    Carlson, C. M.
    McLaughlin, H. P.
    Thornburg, N.
    Tong, S.
    Tamin, A.
    Tao, Y.
    Uehara, A.
    Harcourt, J.
    Clark, S.
    Brostrom-Smith, C.
    Page, L. C.
    Kay, M.
    Lewis, J.
    Montgomery, P.
    Stone, N. D.
    Clark, T. A.
    Honein, M. A.
    Duchin, J. S.
    Jernigan, J. A.
    [J]. NEW ENGLAND JOURNAL OF MEDICINE, 2020, 382 (22) : 2081 - 2090
  • [3] Validation of the Hologic Aptima Unisex and Multitest Specimen Collection Kits Used for Endocervical and Male Urethral Swab Specimens (Aptima Swabs) for Collection of Samples from SARS-CoV-2-Infected Patients
    Avaniss-Aghajani, E.
    Sarkissian, A.
    Fernando, F.
    Avaniss-Aghajani, A.
    [J]. JOURNAL OF CLINICAL MICROBIOLOGY, 2020, 58 (08)
  • [4] Bordi L, 2020, J CLIN VIROL, V128, DOI 10.1016/j.jcv.2020.104416
  • [5] Broughton James P, 2020, medRxiv, DOI 10.1101/2020.03.06.20032334
  • [6] CDC, 2020, DISC TRANSM BAS PREC
  • [7] A familial cluster of pneumonia associated with the 2019 novel coronavirus indicating person-to-person transmission: a study of a family cluster
    Chan, Jasper Fuk-Woo
    Yuan, Shuofeng
    Kok, Kin-Hang
    To, Kelvin Kai-Wang
    Chu, Hin
    Yang, Jin
    Xing, Fanfan
    Liu, Jieling
    Yip, Cyril Chik-Yan
    Poon, Rosana Wing-Shan
    Tsoi, Hoi-Wah
    Lo, Simon Kam-Fai
    Chan, Kwok-Hung
    Poon, Vincent Kwok-Man
    Chan, Wan-Mui
    Ip, Jonathan Daniel
    Cai, Jian-Piao
    Cheng, Vincent Chi-Chung
    Chen, Honglin
    Hui, Christopher Kim-Ming
    Yuen, Kwok-Yung
    [J]. LANCET, 2020, 395 (10223) : 514 - 523
  • [8] Detection of 2019 novel coronavirus (2019-nCoV) by real-time RT-PCR (Publication with Expression of Concern)
    Corman, Victor M.
    Landt, Olfert
    Kaiser, Marco
    Molenkamp, Richard
    Meijer, Adam
    Chu, Daniel K. W.
    Bleicker, Tobias
    Bruenink, Sebastian
    Schneider, Julia
    Schmidt, Marie Luisa
    Mulders, Daphne G. J. C.
    Haagmans, Bart L.
    van der Veer, Bas
    van den Brink, Sharon
    Wijsman, Lisa
    Goderski, Gabriel
    Romette, Jean-Louis
    Ellis, Joanna
    Zambon, Maria
    Peiris, Malik
    Goossens, Herman
    Reusken, Chantal
    Koopmans, Marion P. G.
    Drosten, Christian
    [J]. EUROSURVEILLANCE, 2020, 25 (03) : 23 - 30
  • [9] Comparison of Two High-Throughput Reverse Transcription-PCR Systems for the Detection of Severe Acute Respiratory Syndrome Coronavirus 2
    Craney, Arryn R.
    Velu, Priya D.
    Satlin, Michael J.
    Fauntleroy, Kathy A.
    Callan, Katrina
    Robertson, Amy
    La Spina, Marisa
    Lei, Beryl
    Chen, Anqi
    Alston, Tricia
    Rozman, Anna
    Loda, Massimo
    Rennert, Hanna
    Cushing, Melissa
    Westblade, Lars F.
    [J]. JOURNAL OF CLINICAL MICROBIOLOGY, 2020, 58 (08)
  • [10] FDA, 2020, BIORAD SARS COV 2 DD