A fast rebinning algorithm for 3D positron emission tomography using John's equation

被引:64
作者
Defrise, M [1 ]
Liu, XA [1 ]
机构
[1] Free Univ Brussels, Brussels, Belgium
关键词
D O I
10.1088/0266-5611/15/4/314
中图分类号
O29 [应用数学];
学科分类号
070104 ;
摘要
Volume imaging in positron emission tomography (PET) requires the inversion of the three-dimensional (3D) x-ray transform. The usual solution to this problem is based on 3D filtered-backprojection (FBP), but is slow. Alternative methods have been proposed which factor the 3D data into independent 2D data sets corresponding to the 2D Radon transforms of a stack of parallel slices. Each slice is then reconstructed using 2D FBP. These so-called rebinning methods are numerically efficient but are approximate. In this paper a new exact rebinning method is derived by exploiting the fact that the 3D x-ray transform of a function is the solution to the second-order partial differential equation first studied by John. The method is proposed for two sampling schemes, one corresponding to a pair of infinite plane detectors and another one corresponding to a cylindrical multi-ring PET scanner. The new FORE-J algorithm has been implemented for this latter geometry and was compared with the approximate Fourier rebinning algorithm FORE and with another exact rebinning algorithm, FOREX. Results with simulated data demonstrate a significant improvement in accuracy compared to FORE, while the reconstruction time is doubled. Compared to FOREX, the FORE-J algorithm is slightly less accurate but more than three times faster.
引用
收藏
页码:1047 / 1065
页数:19
相关论文
共 30 条
  • [1] Bailey DL, 1998, THEORY PRACTICE 3D P
  • [2] 3D PET USING A CONVENTIONAL MULTISLICE TOMOGRAPH WITHOUT SEPTA
    CHERRY, SR
    DAHLBOM, M
    HOFFMAN, EJ
    [J]. JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1991, 15 (04) : 655 - 668
  • [3] Fast reconstruction of 3D PET data with accurate statistical modeling
    Comtat, C
    Kinahan, PE
    Defrise, M
    Michel, C
    Townsend, DW
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1998, 45 (03) : 1083 - 1089
  • [4] DAUBEWITHERSPOON ME, 1987, J NUCL MED, V28, P1717
  • [5] Exact and approximate rebinning algorithms for 3-D PET data
    Defrise, M
    Kinahan, PE
    Townsend, DW
    Michel, C
    Sibomana, M
    Newport, DF
    [J]. IEEE TRANSACTIONS ON MEDICAL IMAGING, 1997, 16 (02) : 145 - 158
  • [6] A FACTORIZATION METHOD FOR THE 3D X-RAY TRANSFORM
    DEFRISE, M
    [J]. INVERSE PROBLEMS, 1995, 11 (05) : 983 - 994
  • [7] Edholm P. R., 1986, Proceedings of the SPIE - The International Society for Optical Engineering, V671, P8, DOI 10.1117/12.966672
  • [8] LINOGRAMS IN IMAGE-RECONSTRUCTION FROM PROJECTIONS
    EDHOLM, PR
    HERMAN, GT
    [J]. IEEE TRANSACTIONS ON MEDICAL IMAGING, 1987, 6 (04) : 301 - 307
  • [9] Incremental beamwise backprojection using geometrical symmetries for 3D PET reconstruction in a cylindrical scanner geometry
    Egger, ML
    Joseph, C
    Morel, C
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 1998, 43 (10) : 3009 - 3024
  • [10] 3D RECONSTRUCTION FOR A MULTIRING PET SCANNER BY SINGLE-SLICE REBINNING AND AXIAL DECONVOLUTION
    ERLANDSSON, K
    ESSER, PD
    STRAND, SE
    VANHEERTUM, RL
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 1994, 39 (03) : 619 - 629