Comparison of CT Angiography With MR Angiography in the Preoperative Assessment of Living Kidney Donors

被引:44
作者
Gluecker, Thomas M. [1 ]
Mayr, Michael
schwarz, Jochen [1 ]
Bilecen, Deniz [1 ]
Voegele, Thomas
Steiger, Juerg
Bachmann, Alexander [2 ]
Bongartz, Georg [1 ]
机构
[1] Univ Basel Hosp, Dept Diagnost Radiol, CH-4051 Basel, Switzerland
[2] Univ Basel Hosp, Dept Urol, CH-4051 Basel, Switzerland
关键词
Renal transplantation; MRI; Computer tomography;
D O I
10.1097/TP.0b013e3181890810
中图分类号
R392 [医学免疫学]; Q939.91 [免疫学];
学科分类号
100102 ;
摘要
Background. The aim of the Study was to prospectively compare the diagnostic performance of CT angiography (CTA) with MR angiography (MRA) in the preoperative assessment of living renal donors. Methods. Forty-eight potential living renal donors (mean 51 years, 29-67 years) underwent multislice CTA and gadolinium-enhanced MRA. Six potential donors were excluded. Forty-two donors underwent minimal invasive retroperitoneoscopic nephrectomy (left 36, right 6) and their datasets available for analysis independently performed by two blinded radiologists. The surgical status served as gold standard. Results. In 42 donors (84 kidneys), CTA identified 63 kidneys with I artery (MRI 61), 19 with 2 arteries (MRI 20), one with three arteries (MRI 2), and one with four arteries (MRI 1). Considering only the side with the surgical status available for verification, both CT and MRI correctly characterized 35 of 36 donors with a single renal artery and five of six with one supernumerary artery. Two false positives were two arteries suggested as supernumerary both in CT and MRI not confirmed during surgery. CTA and MRA both correctly identified three accessory renal veins in two donors. Conclusion. CTA and MRA had the same accuracy for characterization of renal vasculature in the preoperative assessment of living renal donors.
引用
收藏
页码:1249 / 1256
页数:8
相关论文
共 59 条
  • [11] CECKA JM, 2001, CLIN TRANSPL, V1
  • [12] Helical CT angiography for examination of living renal donors
    Cochran, ST
    Krasny, RM
    Danovitch, GM
    Rajfer, J
    Barbaric, ZM
    Wilkinson, A
    Rosenthal, JT
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 1997, 168 (06) : 1569 - 1573
  • [13] Open and laparoscopic living donor nephrectomy in Switzerland:: a retrospective assessment of clinical outcomes and the motivation to donate
    Dahm, Felix
    Weber, Markus
    Mueller, Benjamin
    Pradel, Francoise G.
    Laube, Guido F.
    Neuhaus, Thomas J.
    Cao, Claude
    Wuethrich, Rudolf P.
    Thiel, Gilbert T.
    Clavien, Pierre-Alain
    [J]. NEPHROLOGY DIALYSIS TRANSPLANTATION, 2006, 21 (09) : 2563 - 2568
  • [14] DERAUF B, 1987, RADIOL CLIN N AM, V25, P261
  • [15] Contrast enhanced spiral computerized tomography in live kidney donors: A single session for anatomical and functional assessment
    El-Diasty, TA
    Shokeir, AA
    El-Ghar, MEA
    Gad, HM
    Refaie, AF
    El-Din, ABS
    [J]. JOURNAL OF UROLOGY, 2004, 171 (01) : 31 - 34
  • [16] Fleiss J.L., 1981, Statistical methods for rates and proportions, P38
  • [17] EQUIVALENCE OF WEIGHTED KAPPA AND INTRACLASS CORRELATION COEFFICIENT AS MEASURES OF RELIABILITY
    FLEISS, JL
    COHEN, J
    [J]. EDUCATIONAL AND PSYCHOLOGICAL MEASUREMENT, 1973, 33 (03) : 613 - 619
  • [18] Comparison of open and laparoscopic live donor nephrectomy
    Flowers, JL
    Jacobs, S
    Cho, E
    Morton, A
    Rosenberger, WF
    Evans, D
    Imbembo, AL
    Bartlett, ST
    [J]. ANNALS OF SURGERY, 1997, 226 (04) : 483 - 489
  • [19] Gadolinium-enhanced three-dimensional magnetic resonance angiography versus conventional digital subtraction angiography: Which modality is superior in evaluating living kidney donors?
    Giessing, M
    Kroencke, TJ
    Taupitz, M
    Feldmann, C
    Deger, S
    Turk, I
    Budde, K
    Ebeling, V
    Schoenberger, B
    Loening, SA
    [J]. TRANSPLANTATION, 2003, 76 (06) : 1000 - 1002
  • [20] Preoperative evaluation of living renal donors: Comparison of CT angiography and MR angiography
    Halpern, EJ
    Mitchell, DG
    Wechsler, RJ
    Outwater, EK
    Moritz, MJ
    Wilson, GA
    [J]. RADIOLOGY, 2000, 216 (02) : 434 - 439