A silicon metal quality-control standard preparation by means of collaborative trials of Brazilian laboratories

被引:1
作者
Chui, QSH
Bispo, JMD
Iamashita, CO
机构
[1] Univ Sao Francisco, BR-13251900 Itatiba 45, SP, Brazil
[2] Inst Pesquisas Tecnol Estado Sao Paulo SA, SA, IPT, Brazil
关键词
powdered silicon metal; collaborative trial; uncertainty; quality-control standard; homogeneity;
D O I
10.1007/s00769-005-0032-5
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A powdered silicon metal material was prepared as a quality-control standard to provide the Brazilian quality-control laboratories with a means to verify the quality of their results, when determining Ca, Al, Fe, Mn and Ti present as impurities. The material was prepared and its homogeneity tested using one-way ANOVA with an ICP-OES analytical technique. The participating laboratories in the first collaborative trial were requested to use their routine procedures that included XRF, ICP-OES and FAAS techniques to analyse the distributed samples. The statistical analysis results showed that the interlaboratory variabilities were very high. By implementing a suggested protocol to put the solid sample into a solution, the participating laboratories showed better performances in the second run. By attributing values to the prepared material the analytes' results were obtained in a new collaborative trial. Statistically the data were evaluated with two-way ANOVA. The values and their associated uncertainties included inhomogeneity and characterisation uncertainties.
引用
收藏
页码:681 / 685
页数:5
相关论文
共 10 条
[1]  
[Anonymous], 1995, GUID EXPR UNC MEAS
[2]  
*ISO, 1985, CERT REF MAT GEN STA
[3]  
*ISO, 1990, 5725 ISO INT ORG STA
[4]   Homogeneity and stability of reference materials [J].
Linsinger, TPJ ;
Pauwels, J ;
van der Veen, AMH ;
Schimmel, H ;
Lamberty, A .
ACCREDITATION AND QUALITY ASSURANCE, 2001, 6 (01) :20-25
[5]  
LOKKEOWRE E, 2002, SILICON CHEM IND, V6
[6]   Homogeneity testing of reference materials [J].
Pauwels, J ;
Lamberty, A ;
Schimmel, H .
ACCREDITATION AND QUALITY ASSURANCE, 1998, 3 (02) :51-55
[7]   Recent trends in inter-laboratory precision at ppb and sub-ppb concentrations in relation to fitness for purpose criteria in proficiency testing [J].
Thompson, M .
ANALYST, 2000, 125 (03) :385-386
[8]  
THOMPSON M, 1993, J AOAC INT, V76, P4
[9]   Uncertainty calculations in the certification of reference materials - 4. Characterisation and certification [J].
van der Veen, AMH ;
Linsinger, TPJ ;
Schimmel, H ;
Lamberty, A ;
Pauwels, J .
ACCREDITATION AND QUALITY ASSURANCE, 2001, 6 (07) :290-294
[10]   Uncertainty calculations in the certification of reference materials. 2. Homogeneity study [J].
van der Veen, AMH ;
Linsinger, T ;
Pauwels, J .