Improved Diagnostic Performance of High-Sensitivity Cardiac Troponin Assays Is an Artifact of Censored Data

被引:5
作者
Pretorius, Carel J. [1 ,2 ]
Ungerer, Jacobus P. J. [1 ]
机构
[1] Queensland Hlth, Pathol Queensland, Dept Chem Pathol, Brisbane, Qld, Australia
[2] Univ Queensland, Sch Med, Brisbane, Qld, Australia
关键词
ACUTE MYOCARDIAL-INFARCTION; YOUDEN INDEX;
D O I
10.1373/clinchem.2016.262634
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
BACKGROUND: High-sensitivity cardiac troponin assays with improved analytical performance at low concentrations are credited with increased diagnostic sensitivity in acute coronary syndrome patients. We investigated the relationship between analytical sensitivity (detection capability) and diagnostic accuracy and tested the effect of censoring data with a software model. METHOD: We generated 4 sets of results with decreasing detection capability and compared the ROC curves with and without censored data. RESULTS: There was no relationship between diagnostic performance and detection capability. When data were censored the diagnostic accuracy decreased progressively with an increase in the threshold concentration for censoring. The ROC curves constructed with censored data have a characteristic appearance with a straight line between the censoring point and the top right hand corner. CONCLUSIONS: There is not a direct relationship between the diagnostic accuracy and the detection capability of cardiac troponin assays. The artifactual decrease in diagnostic accuracy can be added to the list of reasons why data should not be censored and this practice should be disclosed in studies on diagnostic accuracy. (C) 2016 American Association for Clinical Chemistry
引用
收藏
页码:1654 / 1657
页数:4
相关论文
共 21 条
[1]   Comparison of high sensitivity and contemporary troponin assays for the early detection of acute myocardial infarction in the emergency department [J].
Aldous, Sally J. ;
Florkowski, Chris M. ;
Crozier, Ian G. ;
Elliott, John ;
George, Peter ;
Lainchbury, John G. ;
Mackay, Richard J. ;
Than, Martin .
ANNALS OF CLINICAL BIOCHEMISTRY, 2011, 48 :241-248
[2]  
[Anonymous], 2012, EP17A2 CLSI
[3]   Evaluation of the diagnostic performance of current and next-generation assays for cardiac troponin I in the BWH-TIMI ED Chest Pain Study [J].
Bonaca, Marc P. ;
Ruff, Christian T. ;
Kosowsky, Joshua ;
Conrad, Michael J. ;
Murphy, Sabina A. ;
Sabatine, Marc S. ;
Jarolim, Petr ;
Morrow, David A. .
EUROPEAN HEART JOURNAL-ACUTE CARDIOVASCULAR CARE, 2013, 2 (03) :195-202
[4]  
CLSI, 2011, CLSI Document EP24-A2
[5]   LIMITS OF DETECTION [J].
CRESSIE, N .
CHEMOMETRICS AND INTELLIGENT LABORATORY SYSTEMS, 1994, 22 (02) :161-163
[6]   NOMENCLATURE IN EVALUATION OF ANALYTICAL METHODS INCLUDING DETECTION AND QUANTIFICATION CAPABILITIES (IUPAC RECOMMENDATIONS 1995) [J].
CURRIE, LA .
PURE AND APPLIED CHEMISTRY, 1995, 67 (10) :1699-1723
[7]   Increasingly Sensitive Assays for Cardiac Troponins A Review [J].
de Lemos, James A. .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2013, 309 (21) :2262-2269
[8]   High-Sensitivity Cardiac Troponin T Compared With Standard Troponin T Testing on Emergency Department Admission: How Much Does It Add in Everyday Clinical Practice? [J].
Hammerer-Lercher, Angelika ;
Ploner, Thomas ;
Neururer, Sabrina ;
Schratzberger, Peter ;
Griesmacher, Andrea ;
Pachinger, Otmar ;
Mair, Johannes .
JOURNAL OF THE AMERICAN HEART ASSOCIATION, 2013, 2 (03)
[9]   Being Rational about (Im) precision: A Statement from the Biochemistry Subcommittee of the Joint European Society of Cardiology/American College of Cardiology Foundation/American Heart Association/World Heart Federation Task Force for the Definition of Myocardial Infarction [J].
Jaffe, Allan S. ;
Apple, Fred S. ;
Morrow, David A. ;
Lindahl, Bertil ;
Katus, Hugo A. .
CLINICAL CHEMISTRY, 2010, 56 (06) :941-943
[10]   What to Expect When Measuring High-Sensitivity Troponin Practical Advice for Clinicians [J].
Januzzi, James L., Jr. .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2015, 65 (16) :1665-1667