Electrochemical determination of glutathione based on an electrodeposited nickel oxide nanoparticles-modified glassy carbon electrode

被引:27
作者
Yuan, Baiqing [1 ]
Zeng, Xiaoying [1 ,2 ]
Deng, Dehua [1 ]
Xu, Chunying [1 ]
Liu, Lin [1 ]
Zhang, Jiayu [1 ]
Gao, Yan [1 ]
Pang, Huan [1 ,3 ]
机构
[1] Anyang Normal Univ, Coll Chem & Chem Engn, Anyang 455000, Henan, Peoples R China
[2] Zhengzhou Univ, Sch Pharmaceut Sci, Zhengzhou 450001, Henan, Peoples R China
[3] Nanjing Univ, State Key Lab Coordinat Chem, Nanjing 210093, Jiangsu, Peoples R China
基金
美国国家科学基金会;
关键词
PERFORMANCE LIQUID-CHROMATOGRAPHY; QUINONE MODIFIED ELECTRODE; L-CYSTEINE; AMPEROMETRIC DETERMINATION; CAPILLARY-ELECTROPHORESIS; GRAPHITE ELECTRODE; PHYSIOLOGICAL PH; THIOLS; BIOSENSOR; OXIDATION;
D O I
10.1039/c3ay26536f
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
An electrodeposited nickel oxide nanoparticles (NiONPs)-modified glassy carbon (GC) electrode is presented for the first time and used for electrochemical determination of glutathione (GSH). The NiONPs/GC electrode showed a low oxidation potential toward GSH and a wide linear range for its analysis. Different forms of nickel oxide, electrochemically synthesized in different pH buffer solutions, were investigated for the electrochemical oxidation of GSH. The presented sensor was also applied in the analysis of GSH in the presence of uric acid (UA). In addition, the effects of other interfering species including ascorbic acid (AA), dopamine (DA) and glucose were examined and discussed in detail.
引用
收藏
页码:1779 / 1783
页数:5
相关论文
共 34 条
[1]   Regulatory peptides desmopressin and glutathione voltammetric determination on nickel oxide modified electrodes [J].
Chee, Sze Yin ;
Flegel, Martin ;
Pumera, Martin .
ELECTROCHEMISTRY COMMUNICATIONS, 2011, 13 (09) :963-965
[2]   Miniaturized capillary electrophoresis system with a carbon nanotube microelectrode for rapid separation and detection of thiols [J].
Chen, G ;
Zhang, LY ;
Wang, J .
TALANTA, 2004, 64 (04) :1018-1023
[3]   Electrochemical behavior of cysteine at a CuGeO3 nanowires modified glassy carbon electrode [J].
Dong, YongPing ;
Pei, LiZhai ;
Chu, XiangFeng ;
Zhang, WangBing ;
Zhang, QianFeng .
ELECTROCHIMICA ACTA, 2010, 55 (18) :5135-5141
[4]   Electrochemical biosensor based on graphene oxide-Au nanoclusters composites for L-cysteine analysis [J].
Ge, Shenguang ;
Yan, Mei ;
Lu, Juanjuan ;
Zhang, Meng ;
Yu, Feng ;
Yu, Jinghua ;
Song, Xianrang ;
Yu, Shilin .
BIOSENSORS & BIOELECTRONICS, 2012, 31 (01) :49-54
[5]   Amperometric determination of sulfide at a pre-oxidised nickel electrode in acidic media [J].
Giovanelli, D ;
Lawrence, NS ;
Jiang, L ;
Jones, TGJ ;
Compton, RG .
ANALYST, 2003, 128 (02) :173-177
[6]   The electrocatalytic properties of Arc-MWCNTs and associated 'Carbon Onions' [J].
Henstridge, Martin C. ;
Shao, Lidong ;
Wildgoose, Gregory G. ;
Compton, Richard G. ;
Tobias, Gerard ;
Green, Malcolm L. H. .
ELECTROANALYSIS, 2008, 20 (05) :498-506
[7]   Adsorption effects of electroactive species in dc polarography demonstrated in the case of the anodic waves of cysteine [J].
Heyrovsky, M ;
Vavricka, S .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1997, 423 (1-2) :125-130
[8]   Synthesis of ordered mesoporous carbon/cobalt oxide nanocomposite for determination of glutathione [J].
Hou, Ying ;
Ndamanisha, Jean Chrysostome ;
Guo, Li-ping ;
Peng, Xiao-juan ;
Bai, Jing .
ELECTROCHIMICA ACTA, 2009, 54 (26) :6166-6171
[9]   Determination of thiols by capillary electrophoresis with amperometric detection at a coenzyme pyrroloquinoline quinone modified electrode [J].
Inoue, T ;
Kirchhoff, JR .
ANALYTICAL CHEMISTRY, 2002, 74 (06) :1349-1354
[10]   Electrochemical detection of thiols with a coenzyme pyrroloquinoline quinone modified electrode [J].
Inoue, T ;
Kirchhoff, JR .
ANALYTICAL CHEMISTRY, 2000, 72 (23) :5755-5760