Auto-focusing method for remote gaze tracking camera

被引:8
作者
Lee, Won Oh [1 ]
Lee, Hyeon Chang [1 ]
Cho, Chul Woo [1 ]
Gwon, Su Yeong [1 ]
Park, Kang Ryoung [1 ]
Lee, Heekyung [2 ]
Cha, Jihun [2 ]
机构
[1] Dongguk Univ, Div Elect & Elect Engn, Seoul 100715, South Korea
[2] Elect & Telecommun Res Inst, Taejon 305700, South Korea
关键词
remote gaze tracking; auto-focusing; user-dependent calibration; least squares regression; IRIS RECOGNITION; EYESTRAIN; IMAGES;
D O I
10.1117/1.OE.51.6.063204
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Gaze tracking determines what a user is looking at; the key challenge is to obtain well-focused eye images. This is not easy because the human eye is very small, whereas the required resolution of the image should be large enough for accurate detection of the pupil center. In addition, capturing a user's eye image by a remote gaze tracking system within a large working volume at a long Z distance requires a panning/tilting mechanism with a zoom lens, which makes it more difficult to acquire focused eye images. To solve this problem, a new auto-focusing method for remote gaze tracking is proposed. The proposed approach is novel in the following four ways: First, it is the first research on an auto-focusing method for a remote gaze tracking system. Second by using user-dependent calibration at initial stage, the weakness of the previous methods that use facial width in captured image to estimate Z distance between a user and camera, wherein each person has the individual variation of facial width, is solved. Third, the parameters of the modeled formula for estimating the Z distance are adaptively updated using the least squares regression method. Therefore, the focus becomes more accurate over time. Fourth, the relationship between the parameters and the face width is fitted locally according to the Z distance instead of by global fitting, which can enhance the accuracy of Z distance estimation. The results of an experiment with 10,000 images of 10 persons showed that the mean absolute error between the ground-truth Z distance measured by a Polhemus Patriot device and that estimated by the proposed method was 4.84 cm. A total of 95.61% of the images obtained by the proposed method were focused and could be used for gaze detection. (C) 2012 Society of Photo-Optical Instrumentation Engineers (SPIE). [DOI: 10.1117/1.OE.51.6.063204]
引用
收藏
页数:15
相关论文
共 30 条
[1]   STATISTICAL GUIDELINES FOR CONTRIBUTORS TO MEDICAL JOURNALS [J].
ALTMAN, DG ;
GORE, SM ;
GARDNER, MJ ;
POCOCK, SJ .
BRITISH MEDICAL JOURNAL, 1983, 286 (6376) :1489-1493
[2]  
[Anonymous], 2012, CORR DEP
[3]  
[Anonymous], 1998, Applied Regression Analysis
[4]  
[Anonymous], 2012, PATR
[5]   New Computer Interface Combining Gaze Tracking and Brainwave Measurements [J].
Bang, Jae Won ;
Lee, Eui Chul ;
Park, Kang Ryoung .
IEEE TRANSACTIONS ON CONSUMER ELECTRONICS, 2011, 57 (04) :1646-1651
[6]  
Beymer D, 2003, PROC CVPR IEEE, P451
[7]   Robust gaze-tracking method by using frontal-viewing and eye-tracking cameras [J].
Cho, Chul Woo ;
Lee, Ji Woo ;
Lee, Eui Chul ;
Park, Kang Ryoung .
OPTICAL ENGINEERING, 2009, 48 (12)
[8]   How iris recognition works [J].
Daugman, J .
IEEE TRANSACTIONS ON CIRCUITS AND SYSTEMS FOR VIDEO TECHNOLOGY, 2004, 14 (01) :21-30
[9]   Methodology and apparatus for using the human iris as a robust biometric [J].
DellaVecchia, M ;
Chmielewski, T ;
Camus, T ;
Salganicoff, M ;
Negin, M .
OPHTHALMIC TECHNOLOGIES VIII, PROCEEDINGS OF, 1998, 3246 :65-74
[10]   Self-adaptive iris image acquisition system [J].
Dong, Wenbo ;
Sun, Zhenan ;
Tan, Tieniu ;
Qiu, Xianchao .
BIOMETRIC TECHNOLOGY FOR HUMAN IDENTIFICATION V, 2008, 6944