Experimental study on effect of length of service hole on seismic behavior of exterior precast beam-column connections

被引:15
作者
Liu, Yangqing [1 ]
Cai, Jianguo [1 ]
Deng, Xiaowei [2 ]
Cao, Yunfeng [1 ]
Feng, Jian [1 ]
机构
[1] Southeast Univ, Natl Prestress Engn Res Ctr, Key Lab C&PC Struct, Minist Educ, Nanjing 210096, Jiangsu, Peoples R China
[2] Univ Hong Kong, Dept Civil Engn, Pokfulam, Hong Kong, Peoples R China
关键词
beam-column connection; cyclic load; precast concrete; seismic behavior; test; U-shape; CONCRETE; DESIGN; FRAMES; TESTS; SHEAR;
D O I
10.1002/suco.201700227
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Experimental study is reported on the seismic behavior of a type of exterior beam-column connections, which feature service holes in the connecting ends of the beams. Specimens with three typical lengths of the holes (450, 500, and 400mm) are tested under quasi-static reversed cyclic loading with constant axial compression on columns. Failure modes, hysteretic and skeleton curves, energy dissipation capacity and ductility are investigated and effect of the length of the hole on the seismic behavior of the connection is studied. The results reveal satisfactory seismic performance of the connections with plastic hinges developed at the connecting ends of the beams and no damage to the joint regions. Comparisons between the specimens demonstrate that the connection with 500-mm long hole performs the greatest energy dissipation capacity and the greatest ductility with comparable load-carrying capacity to the connection with 400-mm long hole. Finally, it is feasible and reliable to follow the Chinese code to predict the load-carrying capacity of the connection, when the longitudinal reinforcement is symmetrically arranged.
引用
收藏
页码:85 / 96
页数:12
相关论文
共 24 条
[1]  
ACI 374, 2005, 374 ACI
[2]  
[Anonymous], 2014, Building Code Requirements for Structural Concrete and Commentary, P318, DOI [10.1016/0262-5075(85)90032-6, DOI 10.1016/0262-5075(85)90032-6]
[3]   Behavior of two new moment resisting precast beam to column connections subjected to lateral loading [J].
Bahrami, Saeed ;
Madhkhan, Morteza ;
Shirmohammadi, Fatemeh ;
Nazemi, Nima .
ENGINEERING STRUCTURES, 2017, 132 :808-821
[4]   Beam-column joints in continuous RC frames: Comparison between cast-in-situ and precast solutions [J].
Breccolotti, Marco ;
Gentile, Santino ;
Tommasini, Mauro ;
Materazzi, Annibale Luigi ;
Bonfigli, Massimo Federico ;
Pasqualini, Bruno ;
Colone, Valerio ;
Gianesini, Marco .
ENGINEERING STRUCTURES, 2016, 127 :129-144
[5]  
Brooke NJ, 2011, IMPROVING PERFORMANC
[6]  
[蔡建国 Cai Jianguo], 2012, [中南大学学报. 自然科学版, Journal of Central South University of Science and Technology], V43, P1894
[7]   Plastic Hinge Relocation Methods for Emulative PC Beam-Column Connections [J].
Eom, Tae-Sung ;
Park, Hong-Gun ;
Hwang, Hyeon-Jong ;
Kang, Su-Min .
JOURNAL OF STRUCTURAL ENGINEERING, 2016, 142 (02)
[8]   Ductile connections in precast concrete moment resisting frames [J].
Ertas, O ;
Ozden, S ;
Ozturan, T .
PCI JOURNAL, 2006, 51 (03) :66-+
[9]   Performance assessment of precast concrete segmental bridge columns with a shear resistant connecting structure [J].
Kim, T. -H. ;
Lee, H-M. ;
Kim, Y. -J. ;
Shin, H. M. .
ENGINEERING STRUCTURES, 2010, 32 (05) :1292-1303
[10]   Performance of a precast concrete beam-to-beam connection subject to reversed cyclic loading [J].
Korkmaz, HH ;
Tankut, T .
ENGINEERING STRUCTURES, 2005, 27 (09) :1392-1407