Evaluation of a Powered Ankle-Foot Prosthetic System During Walking

被引:91
作者
Ferris, Abbie E. [1 ]
Aldridge, Jennifer M. [1 ]
Rabago, Christopher A. [1 ]
Wilken, Jason M. [1 ]
机构
[1] San Antonio Mil Med Ctr, Dept Orthopaed & Rehabil, Ctr Intrepid, Ft Sam Houston, TX 78324 USA
来源
ARCHIVES OF PHYSICAL MEDICINE AND REHABILITATION | 2012年 / 93卷 / 11期
关键词
Amputees; Biomechanics; Gait; Lower extremity; Prosthesis design; Rehabilitation; BELOW-KNEE AMPUTEES; COMPENSATORY MECHANISMS; GAIT ANALYSIS; RELIABILITY; SUPPORT; PROGRESSION; KINETICS; VALIDITY; MUSCLES; FEET;
D O I
10.1016/j.apmr.2012.06.009
中图分类号
R49 [康复医学];
学科分类号
100215 ;
摘要
Objective: To determine whether a powered ankle-foot prosthesis improves gait mechanics, physical performance, and user satisfaction after traumatic transtibial amputation. Design: Pre-post. Setting: Gait analysis laboratory. Participants: Young individuals with traumatic transtibial amputation (n=11) and matched controls (n=11). Interventions: Wearing an energy-storing and -returning (ESR) foot and a powered ankle-foot prosthesis. Main Outcome Measures: Gait mechanics, physical performance, and user satisfaction. Results: The powered prosthesis ankle range of motion (ROM) was significantly larger (similar to 30%) than that of the ESR limb. However, both devices demonstrated significantly less ankle ROM than the control and intact limbs. At preswing, the ESR limb generated approximately 40% less peak ankle power than control and intact limbs. In contrast, the powered prosthesis generated significantly greater peak ankle power than control (35%) and ESR (similar to 125%) limbs, resulting in the powered limb absorbing twice the peak knee power observed in the control and intact limbs. The powered prosthesis limb peak hip power generation was approximately 45% greater at preswing than that of the intact limb. Walking velocity increased with the powered prosthesis compared with the ESR limb and was greater than that of the control group. However, physical performance measures were not significantly different between ESR and powered conditions. User satisfaction scores indicated a preference for the powered prosthesis over the ESR limb. Conclusions: Compensatory strategies during gait with the ESR and powered prosthetic devices were similar to those reported in the literature. However, the addition of ankle power and ROM by the powered prosthesis appeared to increase compensatory strategies at proximal joints.
引用
收藏
页码:1911 / 1918
页数:8
相关论文
共 34 条
[1]   Kinematics and kinetics with an adaptive ankle foot system during stair ambulation of transtibial amputees [J].
Alimusaj, Merkur ;
Fradet, Laetitia ;
Braatz, Frank ;
Gerner, Hans J. ;
Wolf, Sebastian I. .
GAIT & POSTURE, 2009, 30 (03) :356-363
[2]   Powered ankle-foot prosthesis to assist level-ground and stair-descent gaits [J].
Au, Samuel ;
Berniker, Max ;
Herr, Hugh .
NEURAL NETWORKS, 2008, 21 (04) :654-666
[3]  
Barth DG., 1992, J PROSTHET ORTHOT, V4, P63, DOI DOI 10.1097/00008526-199200420-00001
[4]  
BATENI H, 2002, J PROSTHET ORTHOT, V14, P2
[5]  
Buell N., 2004, 11 WORLD C INT SOC P
[6]   A six degrees-of-freedom marker set for gait analysis: Repeatability and comparison with a modified Helen Hayes set [J].
Collins, Thomas D. ;
Ghoussayni, Salim N. ;
Ewins, David J. ;
Kent, Jenny A. .
GAIT & POSTURE, 2009, 30 (02) :173-180
[7]   Biomechanical analysis of ramp ambulation of transtibial amputees with an adaptive ankle foot system [J].
Fradet, Laetitia ;
Alimusaj, Merkur ;
Braatz, Frank ;
Wolf, Sebastian I. .
GAIT & POSTURE, 2010, 32 (02) :191-198
[8]   Evaluation of function, performance, and preference as transfemoral amputees transition from mechanical to microprocessor control of the prosthetic knee [J].
Hafner, Brian J. ;
Willingham, Laura L. ;
Buell, Noelle C. ;
Allyn, Katheryn J. ;
Smith, Douglas G. .
ARCHIVES OF PHYSICAL MEDICINE AND REHABILITATION, 2007, 88 (02) :207-217
[9]   Bionic ankle-foot prosthesis normalizes walking gait for persons with leg amputation [J].
Herr, Hugh M. ;
Grabowski, Alena M. .
PROCEEDINGS OF THE ROYAL SOCIETY B-BIOLOGICAL SCIENCES, 2012, 279 (1728) :457-464
[10]   An Active Foot-Ankle Prosthesis With Biomechanical Energy Regeneration [J].
Hitt, Joseph K. ;
Sugar, Thomas G. ;
Holgate, Matthew ;
Bellman, Ryan .
JOURNAL OF MEDICAL DEVICES-TRANSACTIONS OF THE ASME, 2010, 4 (01)