A new approach for optimal shunt active power filter control considering alternative performance indices

被引:41
作者
Chang, GW [1 ]
机构
[1] Natl Chung Cheng Univ, Dept Elect Engn, Chiayi 62107, Taiwan
关键词
active power filter; IEEE-519; nonlinear programming; reference compensation current; reference-frame transformation;
D O I
10.1109/TPWRD.2005.852347
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
A new steady-state approach for determining the optimal shunt active power filter (APF) reference compensation current injections to control harmonic currents generated by the nonlinear load and for reactive power compensation under ideal or nonideal supply voltages are presented in the paper. Conventionally, the compensation currents injected by the shunt APF are determined to eliminate harmonic currents of the load. However, when considering different APF performance indices such as minimizing source current distortion and maximizing compensated load power factor, the issues related to sizing the APF to meet IEEE-519 harmonic current limits and other constraints such as current imbalance limits and minimum load power factor requirement are rarely investigated. In the paper, a new theory of APF control in the a-b-c lreference frame is proposed to determine the APF current injections to meet different constraints with an optimal APF size, where the filter control strategy is formulated as a nonlinear programming problem and is solved to find the optimal current injections. Results obtained by simulations with Matlab/Simulink show that the proposed approach is more flexible and effective than the conventional approaches on compensating reactive power and harmonic currents of the load.
引用
收藏
页码:406 / 413
页数:8
相关论文
共 17 条
[1]   INSTANTANEOUS REACTIVE POWER COMPENSATORS COMPRISING SWITCHING DEVICES WITHOUT ENERGY-STORAGE COMPONENTS [J].
AKAGI, H ;
KANAZAWA, Y ;
NABAE, A .
IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 1984, 20 (03) :625-630
[2]  
[Anonymous], 1992, IEEE Std. 519
[3]  
[Anonymous], P POW CONV C TOK JAP
[4]   Three-phase four-wire shunt active filter control strategies [J].
Aredes, M ;
Hafner, J ;
Heumann, K .
IEEE TRANSACTIONS ON POWER ELECTRONICS, 1997, 12 (02) :311-318
[5]   NEW CONTROL ALGORITHMS FOR SERIES AND SHUNT 3-PHASE 4-WIRE ACTIVE POWER FILTERS [J].
AREDES, M ;
WATANABE, EH .
IEEE TRANSACTIONS ON POWER DELIVERY, 1995, 10 (03) :1649-1656
[6]  
BHATTACHARYA S, 1991, P EPE 91 C, V3, P30
[7]  
Chang GW, 2002, 2002 IEEE POWER ENGINEERING SOCIETY SUMMER MEETING, VOLS 1-3, CONFERENCE PROCEEDINGS, P1017, DOI 10.1109/PESS.2002.1043556
[8]   Neural network controlled three-phase four-wire shunt active power filter [J].
Elmitwally, A ;
Abdelkader, S ;
El-Kateb, M .
IEE PROCEEDINGS-GENERATION TRANSMISSION AND DISTRIBUTION, 2000, 147 (02) :87-92
[9]  
Gyugyi L., 1976, Active ac power filters, P529
[10]   A control algorithm for compensation of customer-generated harmonics and reactive power [J].
Jain, SK ;
Agarwal, P ;
Gupta, HO .
IEEE TRANSACTIONS ON POWER DELIVERY, 2004, 19 (01) :357-366