Significance of late redistribution thallium-201 imaging after rest injection for detection of viable myocardium

被引:0
作者
Matsunari, I
Fujino, S
Taki, J
Senma, J
Aoyama, T
Wakasugi, T
Hirai, J
Saga, T
Yamamoto, S
Tonami, N
机构
[1] FUKUI PREFECTURAL HOSP, DEPT RADIOL, FUKUI, JAPAN
[2] FUKUI PREFECTURAL HOSP, DEPT CARDIOL, FUKUI, JAPAN
[3] FUKUI PREFECTURAL HOSP, DEPT CARDIOVASC SURG, FUKUI, JAPAN
关键词
thallium-201; late redistribution; myocardial viability;
D O I
暂无
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The aim of this study was to determine whether late redistribution imaging after rest injection of Tl-201 would provide further information on myocardial viability over conventional rest-early redistribution Tl-201 imaging. Methods: Twenty-nine patients with coronary artery disease and left ventricular dysfunction underwent rest, early (3-4 hr) and late (20-24 hr) redistribution Tl-201 and gated blood pool studies. In 14 patients with successful revascularization, gated blood pool study was repeated after the coronary intervention. Results: Nine of 29 patients showed early redistribution, and six additional patients showed further redistribution on the late images. Of 136 segments with initial Tl-201 defects, 18 showed early redistribution, and 10 showed late redistribution. When a threshold of 60% of peak activity was used as an index of myocardial viability, only a small fraction (3%) of the initial Tl-201 defects were additionally considered viable by the late images. In 14 patients who underwent revascularization, the positive (69%) and negative (87%) predictive Values of the early redistribution images for functional recovery were similar to those obtained by the late images (68% and 86%, respectively). Conclusion: Although tate redistribution after rest injection of Tl-201 occasionally occurs, most of the clinically relevant information on myocardial viability may be obtained by conventional rest-early redistribution Tl-201 imaging when the defect severity is considered an index of tissue viability.
引用
收藏
页码:1073 / 1078
页数:6
相关论文
共 50 条
[41]   Reverse redistribution on thallium-201 single-photon emission tomography after primary angioplasty: a one-year follow-up study [J].
De Sutter, J ;
Van de Wiele, C ;
Dierckx, R ;
Gheeraert, P ;
De Buyzere, M ;
Taeymans, Y .
EUROPEAN JOURNAL OF NUCLEAR MEDICINE, 1999, 26 (06) :633-639
[42]   Myocardial perfusion and function imaging at rest with simultaneous thallium-201 and technetium-99m blood-pool dual-isotope gated SPECT [J].
Constantinesco, A ;
Mertz, L ;
Brunot, B .
JOURNAL OF NUCLEAR MEDICINE, 1997, 38 (03) :432-437
[43]   Validation in the canine model of a new non-invasive method of measuring coronary blood flow reserve: Split dose thallium-201 rest/stress imaging [J].
Joseph A. Diamond ;
Josef Machac ;
Shankar Vallabhajosula ;
Milena J. Henzlova ;
M. Kazi Ali ;
Craig K. Mezrow ;
Alejandro Gandses ;
Arlene Travis ;
Robert A. Phillips .
The International Journal of Cardiovascular Imaging, 2001, 17 :145-152
[44]   Validation in the canine model of a new non-invasive method of measuring coronary blood flow reserve: Split dose thallium-201 rest/stress imaging [J].
Diamond, JA ;
Machac, J ;
Vallabhajosula, S ;
Henzlova, MJ ;
Ali, MK ;
Mezrow, CK ;
Gandses, A ;
Travis, A ;
Phillips, RA .
INTERNATIONAL JOURNAL OF CARDIAC IMAGING, 2001, 17 (02) :145-152
[45]   Improved diagnostic accuracy of planar imaging with technetium 99m-labeled tetrofosmin compared with thallium-201 for the detection of coronary artery disease [J].
Khattar, RS ;
Hendel, RC ;
Crawley, JCW ;
Wackers, FJ ;
Rigo, P ;
Zaret, BL ;
Sridhara, BS ;
Lahiri, A .
JOURNAL OF NUCLEAR CARDIOLOGY, 1997, 4 (04) :291-297
[46]   Transient ischemic stunning of the myocardium in stress thallium-201 gated SPET myocardial perfusion imaging: segmental analysis of myocardial perfusion, wall motion and wall thickening changes [J].
Santiago, JFY ;
Heiba, SI ;
Jana, S ;
Mirzaitehrane, M ;
Dede, F ;
Abdel-Dayem, HM .
EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2002, 29 (08) :979-983
[47]   Improved diagnostic accuracy of planar imaging with technetium 99m-labeled tetrofosmin compared with thallium-201 for the detection of coronary artery disease [J].
Rajdeep S. Khattar ;
Robert C. Hendel ;
John C. W. Crawley ;
Frans J. Wackers ;
Pierre Rigo ;
Barry L. Zaret ;
Bangalore S. Sridhara ;
Avijit Lahiri .
Journal of Nuclear Cardiology, 1997, 4 :291-297
[48]   DETECTION OF VIABLE MYOCARDIUM IN SEGMENTS WITH FIXED DEFECTS ON TL-201 SCINTIGRAPHY - USEFULNESS OF MAGNETIC-RESONANCE-IMAGING EARLY AFTER ACUTE MYOCARDIAL-INFARCTION [J].
JOHNSTON, DL ;
GUPTA, VK ;
WENDT, RE ;
MAHMARIAN, JJ ;
VERANI, MS .
MAGNETIC RESONANCE IMAGING, 1993, 11 (07) :949-956
[49]   Course of impaired left ventricular function after acute myocardial infarction predicted with planar thallium-201 chloride and F18-fluorodeoxyglucose imaging [J].
Huitink, JM ;
Visser, FC ;
Bax, JJ ;
vanLingen, A ;
Visser, CA .
INTERNATIONAL JOURNAL OF CARDIOLOGY, 1996, 57 (03) :271-281
[50]   ENHANCED DETECTION OF VIABLE MYOCARDIUM BY TECHNETIUM-99M-MIBI IMAGING AFTER NITRATE ADMINISTRATION IN CHRONIC CORONARY-ARTERY DISEASE [J].
MAUREA, S ;
CUOCOLO, A ;
SORICELLI, A ;
CASTELLI, L ;
NAPPI, A ;
SQUAME, F ;
IMBRIACO, M ;
TRIMARCO, B ;
SALVATORE, M .
JOURNAL OF NUCLEAR MEDICINE, 1995, 36 (11) :1945-1952