Improved magnetic circuit analysis of a laminated magnetorheological elastomer device featuring both permanent magnets and electromagnets

被引:12
作者
Li, Shaoqi [1 ]
Watterson, Peter A. [2 ]
Li, Yancheng [1 ,3 ]
Wen, Quan [4 ]
Li, Jianchun [1 ]
机构
[1] Univ Technol Sydney, Fac Engn & Informat Technol, Sch Civil & Environm Engn, Ultimo, NSW 2007, Australia
[2] Univ Technol Sydney, Fac Engn & Informat Technol, Sch Elect & Data Engn, Ultimo, NSW 2007, Australia
[3] Nanjing Tech Univ, Sch Civil Engn, Nanjing 211816, Peoples R China
[4] Nanjing Univ Sci & Technol, Sch Mech Engn, Nanjing 210094, Peoples R China
关键词
magnetorheological elastomer; magnetic circuit modelling; flux fringing effect; permanent magnet; BASE-ISOLATION SYSTEM; FLUID DAMPERS; DESIGN;
D O I
10.1088/1361-665X/ab8029
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
As an essential and critical step, magnetic circuit modelling is usually implemented in the design of efficient and compact magnetorheological (MR) devices, such as MR dampers and MR elastomer isolators. Conventional magnetic circuit analysis simplifies the analysis by ignoring the magnetic flux leakage and magnetic fringing effect. These assumptions are sufficiently accurate in dealing with less complicated designs, featuring short magnetic path lengths such as in an MR damper. However, when dealing with MR elastomer devices, such simplification in magnetic circuit analysis results in inaccuracy of dimensioning and performance estimation of the devices due to their sophisticated design and complex magnetic paths. Modelling permanent magnets also imposes challenges in the magnetic circuit analysis. This work proposes an improved approach to include magnetic flux fringing effect in magnetic circuit analysis for MR elastomer devices. An MRE-based isolator containing multiple MRE layers and both a permanent magnet and an exciting coil was designed and built as a case study. The results of the proposed method are compared to those of conventional magnetic circuit modelling, finite element analysis and experimental measurements to demonstrate the effectiveness of the proposed approach.
引用
收藏
页数:16
相关论文
共 39 条
[1]   Modeling of a magnetorheological actuator including magnetic hysteresis [J].
An, J ;
Kwon, DS .
JOURNAL OF INTELLIGENT MATERIAL SYSTEMS AND STRUCTURES, 2003, 14 (09) :541-550
[2]   Performance of a new magnetorheological elastomer isolation system [J].
Behrooz, Majid ;
Wang, Xiaojie ;
Gordaninejad, Faramarz .
SMART MATERIALS AND STRUCTURES, 2014, 23 (04)
[3]  
BOELTER R, 1997, P SOC PHOTO-OPT INS, V3045, P148
[4]   Soft magnetorheological elastomers as new actuators for valves [J].
Boese, Holger ;
Rabindranath, Raman ;
Ehrlich, Johannes .
JOURNAL OF INTELLIGENT MATERIAL SYSTEMS AND STRUCTURES, 2012, 23 (09) :989-994
[5]   A self-sensing magnetorheological damper with power generation [J].
Chen, Chao ;
Liao, Wei-Hsin .
SMART MATERIALS AND STRUCTURES, 2012, 21 (02)
[6]  
Gavin H., 2001, JAPAN WORKSHOP SMART, P225
[7]   Magnetostrictive phenomena in magnetorheological elastomers [J].
Ginder, JM ;
Clark, SM ;
Schlotter, WF ;
Nichols, ME .
INTERNATIONAL JOURNAL OF MODERN PHYSICS B, 2002, 16 (17-18) :2412-2418
[8]   Magnetorheological elastomers in tunable vibration absorbers [J].
Ginder, JM ;
Schlotter, WF ;
Nichols, ME .
SMART STRUCTURES AND MATERIALS 2001: DAMPING AND ISOLATION, 2001, 4331 :103-110
[9]   Design of magneto-rheological (MR) valve [J].
Grunwald, A. ;
Olabi, A. G. .
SENSORS AND ACTUATORS A-PHYSICAL, 2008, 148 (01) :211-223
[10]   Experimental realisation of the real-time controlled smart magnetorheological elastomer seismic isolation system with shake table [J].
Gu, Xiaoyu ;
Li, Jianchun ;
Li, Yancheng .
STRUCTURAL CONTROL & HEALTH MONITORING, 2020, 27 (01)