The 10B based Jalousie neutron detector - An alternative for 3He filled position sensitive counter tubes

被引:40
作者
Henske, M. [2 ]
Klein, M. [1 ,2 ]
Koehli, M. [1 ]
Lennert, P. [1 ]
Modzel, G. [1 ]
Schmidt, C. J. [2 ,3 ]
Schmidt, U. [1 ]
机构
[1] Univ Heidelberg, Inst Phys, D-69120 Heidelberg, Germany
[2] CDT CASCADE Detector Technol GmbH, D-69123 Heidelberg, Germany
[3] GSI Detector Lab, D-64291 Darmstadt, Germany
关键词
Neutron detector; B-10; Position sensitive; Large area; He-3; alternative; ASIC; Integrated readout; FPGA;
D O I
10.1016/j.nima.2012.05.075
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Over the last decades He-3 filled proportional counter tubes were the working horse employed to serve as neutron counters especially in cases where large area coverage was required. Today the lack of He-3 demands the development of an alternative technology. Here we present a prototype neutron detector that is based on a concept with solid B-10 as neutron converter and aims for large area neutron detection applications. We report on first experimental results obtained with this prototype to demonstrate the feasibility and operational readiness of our concept. (C) 2012 Elsevier By. All rights reserved.
引用
收藏
页码:151 / 155
页数:5
相关论文
共 8 条
[1]  
[Anonymous], 2009, SCIENCE, V326, P778
[2]   A vertex trigger based on cylindrical multiwire proportional chambers [J].
Becker, J. ;
Boesiger, K. ;
Lindfeld, L. ;
Mueller, K. ;
Robmann, P. ;
Schmitt, S. ;
Schmitz, C. ;
Steiner, S. ;
Straumann, U. ;
Szeker, K. ;
Truoel, P. ;
Urban, M. ;
Vollhardt, A. ;
Werner, N. ;
Baumeister, D. ;
Loechner, S. ;
Hildebrandt, M. .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2008, 586 (02) :190-203
[3]  
Houben A., 20072008 JCNS
[4]  
KLEIN M, 2000, THESIS U HEIDELBERG
[5]   CASCADE, neutron detectors for highest count rates in combination with ASIC/FPGA based readout electronics [J].
Klein, Martin ;
Schmidt, Christian J. .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2011, 628 (01) :9-18
[6]   Design considerations for thin film coated semiconductor thermal neutron detectors - I: basics regarding alpha particle emitting neutron reactive films [J].
McGregor, DS ;
Hammig, MD ;
Yang, YH ;
Gersch, HK ;
Klann, RT .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2003, 500 (1-3) :272-308
[7]   The high-resolution time-of-flight spectrometer TOFTOF [J].
Unruh, Tobias ;
Neuhaus, Juergen ;
Petry, Winfried .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2007, 580 (03) :1414-1422
[8]  
Ziegler J., SRIM