Evaluation of a bedside device to assess the activated partial thromboplastin time for heparin monitoring in infants

被引:2
作者
Klein, Richard H. [1 ,2 ]
van der Vorst, Marja M. J. [1 ,3 ]
de Wilde, Rob B. P. [4 ]
Hogenbirk, Karin [4 ]
de Kam, Marieke L. [1 ]
Burggraaf, Jacobus [1 ]
机构
[1] Leiden Univ, Med Ctr, Ctr Human Drug Res, Leiden, Netherlands
[2] Leiden Univ, Med Ctr, Dept Paediat, Leiden, Netherlands
[3] St Antonius Hosp, Dept Paediat, Nieuwegein, Netherlands
[4] Leiden Univ, Med Ctr, Ctr Intens Care, Leiden, Netherlands
关键词
coagulation; heparin; monitoring; pediatric intensive care; MOLECULAR-WEIGHT HEPARIN; PEDIATRIC-PATIENTS; UNFRACTIONATED HEPARIN; CARDIOPULMONARY BYPASS; ANTITHROMBOTIC THERAPY; COAGULATION ANALYZER; HEMOSTATIC SYSTEM; CARDIAC-SURGERY; CLOTTING TIME; ANTICOAGULATION;
D O I
10.1097/MBC.0b013e32835d070d
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
To determine the relationship between the activated partial thromboplastin time (aPTT) measured with a standard laboratory assay and the aPTT measured with a bedside device in infants on heparin therapy after cardiothoracic surgery. Twenty infants aged below 1 year who were on heparin therapy were included. Exclusion criteria were prematurity, dysmaturity and the use of anticoagulants other than heparin. Nineteen samples were obtained from four adults in intensive care who were on heparin. The aPTT values were analyzed with the Coaguchek Pro/DM bedside device (aPTTbed) and compared with the aPTT values obtained from the laboratory Electra 1800C coagulation analyzer (aPTTlab). Correlation analysis was performed by linear regression. The agreement was calculated using Bland-Altman analysis. The correlation coefficient of samples obtained from infants was lower (r=0.48) compared with samples from adults (r=0.85). A substantial positive bias (27 s) and scatter [95% confidence interval (CI) -11; +65 s) was found. The bias showed a genuine trend to increase at higher aPTT values (r=0.90; P<0.001). The bedside device overestimates the aPTT in infants treated with heparin. The disagreement between the bedside device and laboratory increases at higher aPTTs. Bedside devices should not be used to monitor heparin therapy in infants in intensive care. Blood Coagul Fibrinolysis 24:327-331 (C) 2013 Wolters Kluwer Health vertical bar Lippincott Williams & Wilkins.
引用
收藏
页码:327 / 331
页数:5
相关论文
共 31 条
[1]  
ANDREW M, 1994, THROMB HAEMOSTASIS, V71, P265
[2]  
ANDREW M, 1994, THROMB HAEMOSTASIS, V72, P836
[3]  
ANDREW M, 1990, AM J PEDIAT HEMATOL, V12, P95
[4]   MATURATION OF THE HEMOSTATIC SYSTEM DURING CHILDHOOD [J].
ANDREW, M ;
VEGH, P ;
JOHNSTON, M ;
BOWKER, J ;
OFOSU, F ;
MITCHELL, L .
BLOOD, 1992, 80 (08) :1998-2005
[5]   HEPARIN-THERAPY IN PEDIATRIC-PATIENTS - A PROSPECTIVE COHORT STUDY [J].
ANDREW, M ;
MARZINOTTO, V ;
MASSICOTTE, P ;
BLANCHETTE, V ;
GINSBERG, J ;
BRILLEDWARDS, P ;
BURROWS, P ;
BENSON, L ;
WILLIAMS, W ;
DAVID, M ;
POON, A ;
SPARLING, K .
PEDIATRIC RESEARCH, 1994, 35 (01) :78-83
[6]   COMPARING METHODS OF MEASUREMENT - WHY PLOTTING DIFFERENCE AGAINST STANDARD METHOD IS MISLEADING [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1995, 346 (8982) :1085-1087
[7]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[8]   Evaluation of a point-of-care coagulation analyzer on patients undergoing cardiopulmonary bypass surgery [J].
Chavez, JJ ;
Weatherall, JS ;
Strevels, SM ;
Liu, FQ ;
Snider, CC ;
Carroll, RC .
JOURNAL OF CLINICAL ANESTHESIA, 2004, 16 (01) :7-10
[9]   A STANDARD HEPARIN NOMOGRAM FOR THE MANAGEMENT OF HEPARIN-THERAPY [J].
CRUICKSHANK, MK ;
LEVINE, MN ;
HIRSH, J ;
ROBERTS, R ;
SIGUENZA, M .
ARCHIVES OF INTERNAL MEDICINE, 1991, 151 (02) :333-337
[10]   EFFECT OF HEPARIN ON WHOLE-BLOOD ACTIVATED PARTIAL THROMBOPLASTIN TIME USING A PORTABLE, WHOLE-BLOOD COAGULATION MONITOR [J].
DESPOTIS, GJ ;
HOGUE, CW ;
SANTORO, SA ;
JOIST, JH ;
BARNES, PW ;
LAPPAS, DG .
CRITICAL CARE MEDICINE, 1995, 23 (10) :1674-1679