Evaluation of Transmission and Reflection Modalities for Measuring Content Uniformity of Pharmaceutical Tablets with Near-Infrared Spectroscopy

被引:13
作者
Xiang, Dong [1 ]
Lobrutto, Rosario [1 ]
Cheney, James [1 ]
Wabuyele, Busolo Wa [1 ]
Berry, Joseph [2 ]
Lyon, Robbe [3 ]
Wu, Huiquan [3 ]
Khan, Mansoor A. [3 ]
Hussain, Ajaz S. [4 ]
机构
[1] Nova Pharmaceut Corp, Pharmaceut & Analyt Dev, E Hanover, NJ 07936 USA
[2] QRxPharma Inc, Tech Operat, Bedminster, NJ 07921 USA
[3] OTR, OPS, CDER, FDA,Div Prod Qual Res, Silver Spring, MD 20993 USA
[4] Phillip Morris Int Res & Dev, Philip Morris Prod SA, CH-2000 Neuchatel, Switzerland
关键词
Near-infrared spectroscopy; NIR spectroscopy; Transmission; Diffuse reflection; Pharmaceutical tablets; Content uniformity; Partial least squares; PLS regression; INTACT TABLETS; AQUEOUS-SOLUTIONS; ACTIVE-SUBSTANCE; QUALITY-CONTROL; DOSAGE FORMS; ASSAY; VALIDATION; QUANTITATION; TRANSMITTANCE; QUANTIFICATION;
D O I
10.1366/000370209787169696
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
This paper examines how one may assess spectral changes with instrument configuration (or composition), in combination with the spectral changes in the measurement that are caused by experimental effects, and subsequently select an appropriate measurement modality for tablet content uniformity determination with near-infrared (NIR) spectroscopy. Two NIR spectrometers furnished with three configurations in the sample measurement interface were evaluated. One spectrometer, Broker MPA (multiple purpose analyzer), was equipped with two measurement modalities, diffuse transmission (DT) and diffuse reflection based on integrating sphere optics (DR/IS). The other spectrometer, Broker StepOne, was equipped only with diffuse reflection mode based on a fiber-optic probe (DR/FO). The data were collected with each of the configurations for the tablets associated with two dosage strengths differing significantly in diameter and thickness. Spectral diagnosis was performed in terms of sensitivity and selectivity. The signal-to-noise ratio computed for the data collected with the DT and DR/IS spectrometers was approximately an order of magnitude greater than that computed for the DR/FO spectrometer. The net-analyte-signal-based selectivity analysis of NIR spectra associated with the sample tablet and the placebo tablet indicated that both transmission and reflection mode provided similar selectivity when the optimal spectral range was chosen. A partial least squares (PLS) calibration model was developed for each data set. The overall standard error of calibration for each DT and DR/IS measurement was approximately 0.3% in weight for each strength, significantly better than the value of 1.0% in weight produced by the DR/FO measurement. This result was consistent with the sensitivity analysis based on spectral noise characterization. The poor analytical performance of the DR/FO spectrometer was attributed to the small illumination spot size of the reflection probe and thus the sensitivity of the measurements to the tablet engraving. The PLS analysis and spectral diagnostics both showed that transmission and reflection modes based on the Bruker MPA provided similar measurement accuracy for each strength. However, the robustness study clearly revealed that the transmission mode would be more robust than the reflection mode when there is considerable variability in the chemical composition and physical properties of tablets.
引用
收藏
页码:33 / 47
页数:15
相关论文
共 38 条
[1]   Comparison of different variable selection methods conducted on NIR transmission measurements on intact tablets [J].
Abrahamsson, C ;
Johansson, J ;
Sparén, A ;
Lindgren, F .
CHEMOMETRICS AND INTELLIGENT LABORATORY SYSTEMS, 2003, 69 (1-2) :3-12
[2]   Simultaneous quantitation of five active principles in a pharmaceutical preparation:: Development and validation of a near infrared spectroscopic method [J].
Blanco, M ;
Alcalá, M .
EUROPEAN JOURNAL OF PHARMACEUTICAL SCIENCES, 2006, 27 (2-3) :280-286
[3]   Content uniformity and tablet hardness testing of intact pharmaceutical tablets by near infrared spectroscopy -: A contribution to process analytical technologies [J].
Blanco, M ;
Alcalá, M .
ANALYTICA CHIMICA ACTA, 2006, 557 (1-2) :353-359
[4]   Quantitation of the active compound and major excipients in a pharmaceutical formulation by near infrared diffuse reflectance spectroscopy with fibre optical probe [J].
Blanco, M ;
Coello, J ;
Iturriaga, H ;
Maspoch, S ;
delaPezuela, C .
ANALYTICA CHIMICA ACTA, 1996, 333 (1-2) :147-156
[5]   Identification and quantitation assays for intact tablets of two related pharmaceutical preparations by reflectance near-infrared spectroscopy:: validation of the procedure [J].
Blanco, M ;
Eustaquio, A ;
González, JM ;
Serrano, D .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2000, 22 (01) :139-148
[6]   Effect of data preprocessing methods in near-infrared diffuse reflectance spectroscopy for the determination of the active compound in a pharmaceutical preparation [J].
Blanco, M ;
Coello, J ;
Iturriaga, H ;
Maspoch, S ;
delaPezuela, C .
APPLIED SPECTROSCOPY, 1997, 51 (02) :240-246
[7]   Development and validation of a near infrared method for the analytical control of a pharmaceutical preparation in three steps of the manufacturing process [J].
Blanco, M ;
Coello, J ;
Iturriaga, H ;
Maspoch, S ;
Pou, N .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 2000, 368 (05) :534-539
[8]   A process analytical technology approach based on near infrared spectroscopy:: Tablet hardness, content uniformity, and dissolution test measurements of intact tablets [J].
Blanco, Marcelo ;
Alcala, Manel ;
Gonzalez, Josep M. ;
Torrasz, Ester .
JOURNAL OF PHARMACEUTICAL SCIENCES, 2006, 95 (10) :2137-2144
[9]   Application of transmission near-infrared spectroscopy to uniformity of content testing of intact steroid tablets [J].
Broad, NW ;
Jee, RD ;
Moffat, AC ;
Smith, MR .
ANALYST, 2001, 126 (12) :2207-2211
[10]   USES OF NEAR-INFRARED SPECTROSCOPY IN PHARMACEUTICAL ANALYSIS [J].
CIURCZAK, EW .
APPLIED SPECTROSCOPY REVIEWS, 1987, 23 (1-2) :147-163