Morphological and mechanical information of coronary arteries obtained with intravascular elastography - Feasibility study in vivo

被引:106
作者
de Korte, CL
Carlier, SG
Mastik, F
Doyley, MM
van der Steen, AFW
Serruys, PW
Bom, N
机构
[1] Erasmus Univ, Thoraxctr, NL-3000 DR Rotterdam, Netherlands
[2] Interuniv Cardiol Inst Netherlands, Utrecht, Netherlands
关键词
IVUS elastography; atherosclerosis; coronary artery disease; ultrasound;
D O I
10.1053/euhj.2001.2806
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Aims: Plaque composition is a major determinant of coronary related clinical syndromes. In vitro experiments on human coronary and femoral arteries have demonstrated that different plaque types were detectable with intravascular ultrasound elastography. The aim of this study was to investigate the feasibility of applying intravascular elastography during interventional catheterization procedures. Methods and Results: Data were acquired in patients (n=12) during PTCA procedures with an EndoSonics InVision echoapparatus equipped with radiofrequency output. The systemic pressure was used to strain the tissue, and the strain was determined using cross-correlation analysis of sequential frames. A likelihood function was determined to obtain the frames with minimal motion of the catheter in the lumen, since motion of the catheter prevents reliable strain estimation. Minimal motion was observed near end-diastole. Reproducible strain estimates were obtained within one pressure cycle and over several pressure cycles. Validation of the results was limited to the information provided by the echogram. Strain in calcified material (0.20% +/- 0.07) was lower (P<0.001) than in non-calcified tissue (0.51% +/- 0.20). Conclusion: In vivo intravascular elastography is feasible. Significantly higher strain values were found in non-calcified plaques than in calcified plaques. (Eur Heart J 2002; 23: 405-413, doi:10.1053/euhj.2001.2806) (C) 2001 The European Society of Cardiology.
引用
收藏
页码:405 / 413
页数:9
相关论文
共 56 条
  • [1] Axial movement of the intravascular ultrasound probe during the cardiac cycle: Implications for three-dimensional reconstruction and measurements of coronary dimensions
    Arbab-Zadeh, A
    DeMaria, AN
    Penny, WF
    Russo, RJ
    Kimura, BJ
    Bhargava, V
    [J]. AMERICAN HEART JOURNAL, 1999, 138 (05) : 865 - 872
  • [2] Simulation of circular array ultrasound transducers for intravascular applications
    Borsboom, JMG
    Céspedes, EI
    van der Steen, AFW
    Lancèe, CT
    Deprettere, EF
    [J]. JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 2000, 108 (02) : 827 - 835
  • [3] Botnar RM, 2000, CIRCULATION, V102, P2582
  • [4] BOUMA C, 1998, THESIS UTRECHT U UTR
  • [5] Brennan JF, 1997, CIRCULATION, V96, P99
  • [6] Assessing atherosclerotic plaque morphology: Comparison of optical coherence tomography and high frequency intravascular ultrasound
    Brezinski, ME
    Tearney, GJ
    Weissman, NJ
    Boppart, SA
    Bouma, BE
    Hee, MR
    Weyman, AE
    Swanson, EA
    Southern, JF
    Fujimoto, JG
    [J]. HEART, 1997, 77 (05) : 397 - 403
  • [7] Correlation of ultrasonic attenuation (30 to 50 mhz) and constituents of atherosclerotic plaque
    Bridal, SL
    Fornes, P
    Bruneval, P
    Berger, G
    [J]. ULTRASOUND IN MEDICINE AND BIOLOGY, 1997, 23 (05) : 691 - 703
  • [8] Coronary risk factors and plaque morphology in men with coronary disease who died suddenly
    Burke, AP
    Farb, A
    Malcom, GT
    Liang, YH
    Smialek, J
    Virmani, R
    [J]. NEW ENGLAND JOURNAL OF MEDICINE, 1997, 336 (18) : 1276 - 1282
  • [9] Thermal detection of cellular infiltrates in living atherosclerotic plaques: Possible implications for plaque rupture and thrombosis
    Casscells, W
    Hathorn, B
    David, M
    Krabach, T
    Vaughn, WK
    McAllister, HA
    Bearman, G
    Willerson, JT
    [J]. LANCET, 1996, 347 (9013) : 1447 - 1449
  • [10] Echo decorrelation from displacement gradients in elasticity and velocity estimation
    Céspedes, EI
    de Korte, CL
    van der Steen, AFW
    [J]. IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 1999, 46 (04) : 791 - 801