To POP or Not: Ossiculoplasty in Congenital Aural Atresia Surgery

被引:19
作者
Dobratz, Eric J. [1 ]
Rastogi, Akhil [2 ]
Jahrsdoerfer, Robert A. [1 ]
Kesser, Bradley W. [1 ]
机构
[1] Univ Virginia Hlth Syst, Dept Otolaryngol Head & Neck Surg, Charlottesville, VA 22908 USA
[2] Univ Virginia, Sch Med, Charlottesville, VA 22908 USA
关键词
Ossiculoplasty; congenital aural atresia; partial ossicular replacement prosthesis; total ossicular replacement prosthesis;
D O I
10.1097/MLG.0b013e3181753354
中图分类号
R-3 [医学研究方法]; R3 [基础医学];
学科分类号
1001 ;
摘要
Objectives/Hypothesis: To examine indications for ossiculoplasty (OP) in aural atresia surgery and to compare audiometric results and surgical revision rates between patients undergoing OP and those undergoing intact native chain reconstruction (INCR). Study Design: Retrospective chart review. Methods: Charts of patients undergoing surgery for congenital aural atresia were reviewed for demographic data, preoperative Jahrsdoerfer score, ossicular chain status, and audiometric data. Patients undergoing OP were compared with an equal number of age and Jahrsdoerfer grade-matched patients who had an INCR. The preoperative and postoperative average air-bone gap (ABG), speech reception thresholds (SRT), and rates of revision surgery were compared between the two groups. Results: Nineteen patients (20 ears) underwent OP during aural atresia repair and were compared with 20 matched patients who had INCR. Mean age, Jahrsdoerfer score, preoperative ABG, and SRT were similar for both groups. Mean postoperative audiometric follow-up was 33.1 months for the OP group and 20.4 months for the INC group (P = .24). Mean postoperative ABG was 33.8 dB HL for OP and 23.8 dB HL for INCR (P < .05). Mean improvement in ABG was 16.8 dB HL for OP and 29.9 dB HL for INCR (P < .001). Mean improvement in SRT was 24.6 dB HL for OP and 34.8 dB HL for INCR (P < .05). Nine ears (45%) in the OP group and four ears (20%) in the INCR group underwent revision surgery (P = .09). Conclusions: Patients reconstructed with their own intact native chain during aural atresia surgery have better audiometric outcomes than those undergoing OP and are less likely to undergo revision surgery.
引用
收藏
页码:1452 / 1457
页数:6
相关论文
共 5 条
[1]   Congenital aural atresia surgery: Long-term results [J].
De la Cruz, A ;
Teufert, KB .
OTOLARYNGOLOGY-HEAD AND NECK SURGERY, 2003, 129 (01) :121-127
[2]   Congenital aural atresia: Review of short- and long-term surgical results [J].
Digoy, G. Paul ;
Cueva, Roberto A. .
OTOLOGY & NEUROTOLOGY, 2007, 28 (01) :54-60
[3]  
JAHRSDOERFER RA, 1992, AM J OTOL, V13, P6
[4]   Congenital aural atresia: Stability of surgical results [J].
Lambert, PR .
LARYNGOSCOPE, 1998, 108 (12) :1801-1805
[5]   COMMITTEE ON HEARING AND EQUILIBRIUM GUIDELINES FOR THE EVALUATION OF RESULTS OF TREATMENT OF CONDUCTIVE HEARING-LOSS [J].
MONSELL, EM ;
BALKANY, TA ;
GATES, GA ;
GOLDENBERG, RA ;
MEYERHOFF, WL ;
HOUSE, JW .
OTOLARYNGOLOGY-HEAD AND NECK SURGERY, 1995, 113 (03) :186-187