Integration of biomass gasification with a solid oxide fuel cell in a combined cooling, heating and power system: A thermodynamic and environmental analysis

被引:152
作者
Gholamian, E. [1 ]
Zare, V. [2 ]
Mousavi, Seyed Mostafa [3 ]
机构
[1] Univ Tabriz, Fac Mech Engn, Tabriz, Iran
[2] Urmia Univ Technol, Fac Mech Engn, Orumiyeh, Iran
[3] Shahid Beheshty Univ, Fac Mech & Energy Engn, Tehran, Iran
关键词
SOFC; Biomass; Syngas; Gasifier Greenhouse gas emission; CCHP; ABSORPTION-REFRIGERATION SYSTEMS; OF-THE-ART; TRIGENERATION SYSTEM; PERFORMANCE ANALYSIS; EXERGY ANALYSES; HYBRID SYSTEM; ENERGY; SOFC; TECHNOLOGY; GASIFIER;
D O I
10.1016/j.ijhydene.2016.07.217
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
A biomass-fueled combined cooling, heating and power (CCHP) system is proposed and thermodynamically assessed. The system consists of a biomass gasifier (as the primary energy source), a solid oxide fuel cell (as the power generation unit), a double effect absorption refrigeration cycle (for cooling production) and a HRSG (for steam production for heating purposes). Taking into account the environmental considerations, energy and exergy analyses are conducted for the proposed system and its performance is compared with the corresponding power generation unit and the CHP system. Through a parametric study it is observed that the current density and fuel utilization factor play key roles on the system performance. In addition, considering the system as a combination of three subsystems, i.e. the SOFC, CHP system and CCHP system, an environmental impact assessment in terms of CO2 emission is conducted. Municipal solid waste is examined as biomass and it is observed that maximum exergy efficiency of the CCHP system is 37.92% with a CO2 emission of 20.37 t/MWh which shows an increase of 49.88% in exergy efficiency and 64.02% decrease in CO2 emission, compared to the solo SOFC system. It is concluded that the air heat exchanger and the gasifier are two major sources of irreversibility in the system and the exergy loss is considerable compared to after burners' exergy destruction. (C) 2016 Hydrogen Energy Publications LLC. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:20396 / 20406
页数:11
相关论文
共 49 条
[1]   Biomass gasification cogeneration - A review of state of the art technology and near future perspectives [J].
Ahrenfeldt, Jesper ;
Thomsen, Tobias P. ;
Henriksen, Ulrik ;
Clausen, Lasse R. .
APPLIED THERMAL ENGINEERING, 2013, 50 (02) :1407-1417
[2]   An analysis of SOFC/GT CHP system based on exergetic performance criteria [J].
Akkaya, Ali Volkan ;
Sahin, Bahri ;
Erdem, Hasan Huseyin .
INTERNATIONAL JOURNAL OF HYDROGEN ENERGY, 2008, 33 (10) :2566-2577
[3]   Exergetic performance coefficient analysis of a simple fuel cell system [J].
Akkaya, Ali Volkan ;
Sahin, Bahri ;
Erdem, Hasan Huseyin .
INTERNATIONAL JOURNAL OF HYDROGEN ENERGY, 2007, 32 (17) :4600-4609
[4]   Energy and exergy analyses of a biomass trigeneration system using an organic Rankine cycle [J].
Al-Sulaiman, Fahad A. ;
Dincer, Ibrahim ;
Hamdullahpur, Feridun .
ENERGY, 2012, 45 (01) :975-985
[5]   Energy analysis of a trigeneration plant based on solid oxide fuel cell and organic Rankine cycle [J].
Al-Sulaiman, Fahad A. ;
Dincer, Ibrahim ;
Hamdullahpur, Feridun .
INTERNATIONAL JOURNAL OF HYDROGEN ENERGY, 2010, 35 (10) :5104-5113
[6]  
[Anonymous], 1986, ALTERN ENERGY AGR
[7]  
[Anonymous], 2003, FUEL CELL SYSTEMS EX
[8]   Exergy analysis and optimization of a biomass gasification, solid oxide fuel cell and micro gas turbine hybrid system [J].
Bang-Moller, C. ;
Rokni, M. ;
Elmegaard, B. .
ENERGY, 2011, 36 (08) :4740-4752
[9]  
Baxter D, 2013, WOODHEAD PUBL SER EN, pXXVII
[10]  
Bejan A, 1996, Thermal Design and Optimization