Application of porous foams for size-selective measurements of airborne wheat allergen

被引:11
作者
Bogdanovic, J [1 ]
De Pater, AJ
Doekes, G
Wouters, IM
Heederik, DJJ
机构
[1] Univ Utrecht, Inst Risk Assessment Sci, Utrecht, Netherlands
[2] TNO, Qual Life, NL-3700 AJ Zeist, Netherlands
关键词
airborne wheat allergen; bakers' asthma; respirable foams; size-selective measurements; thoracic foams;
D O I
10.1093/annhyg/mei050
中图分类号
R1 [预防医学、卫生学];
学科分类号
1004 ; 120402 ;
摘要
Background: Exposure to airborne wheat allergen is a well-known cause of bakers' allergy and asthma. Airborne wheat allergen can be measured by enzyme immunoassays (EIAs) in extracts of inhalable dust samples, but only limited knowledge is available on the size distribution of wheat allergen-carrying particles. Recently, a new sampling medium, porous polyurethane foam, has been introduced for the size-selective sampling of airborne dust in various occupational settings. We investigated the applicability of these foams for size-selective wheat allergen measurements. Methods: Personal and stationary measurements were performed in a flour mill, using respirable and thoracic foams inserted into the conventional IOM inhalable sampler, together with PTFE (Teflon) filters. Foams and filters were eluted and wheat allergen levels determined by human IgG4 inhibition EIA. Results: Wheat allergen levels could be determined in both filter and foam eluates. Inhalable dust levels from filters and foams ranged from 1.4 to 53 mg m(-3), and wheat allergen levels from 15 to 580 mu g m(-3). The allergen was mainly borne on particles with D-ae (particle aerodynamic diameter) > 10 mu m and particles with 4 mu m < D-ae <= 10 mu m, accounting for 54.5-77.5% and 18.9-43.2% of the total allergen yield, respectively. Less than 4% of airborne wheat allergen was carried by particles smaller than 4 mu m (respirable fraction). Conclusions: Measurement of wheat allergen in dust fractions trapped in respirable and thoracic foams is technically feasible. Both wheat flour dust and wheat allergen are mainly concentrated in larger particle-size fractions (extrathoracic and tracheobronchial).
引用
收藏
页码:131 / 136
页数:6
相关论文
共 23 条
  • [1] ACGIH, 1998, PART SIZ SEL SAMPL P
  • [2] Aitken R. J., 1993, APPL OCCUP ENV HYG, V8, P363
  • [3] [Anonymous], 1995, Air quality - particle size fraction definitions for health related sampling
  • [4] SIZE DISTRIBUTION OF THE URBAN AEROSOL IN VIENNA
    BERNER, A
    LURZER, C
    POHL, F
    PREINING, O
    WAGNER, P
    [J]. SCIENCE OF THE TOTAL ENVIRONMENT, 1979, 13 (03) : 245 - 261
  • [5] Cen, 1993, 4811993 BS EN
  • [6] Chen CC, 1998, AM IND HYG ASSOC J, V59, P766, DOI 10.1202/0002-8894(1998)059<0766:DORASU>2.0.CO
  • [7] 2
  • [8] Development and testing of a new sampler for welding fume
    Chung, KYK
    Aitken, RJ
    Bradley, DR
    [J]. ANNALS OF OCCUPATIONAL HYGIENE, 1997, 41 (03) : 355 - 372
  • [9] Houba R, 1998, AM J IND MED, V34, P529, DOI 10.1002/(SICI)1097-0274(199812)34:6&lt
  • [10] 529::AID-AJIM1&gt