Imaging for Ventricular Function and Myocardial Recovery on Nonpulsatile Ventricular Assist Devices

被引:26
作者
Estep, Jerry D. [1 ,2 ]
Chang, Su Min [1 ,2 ]
Bhimaraj, Arvind [1 ,2 ]
Torre-Amione, Guillermo [1 ,2 ,3 ]
Zoghbi, William A. [1 ,2 ]
Nagueh, Sherif F. [1 ,2 ]
机构
[1] Methodist DeBakey Heart & Vasc Ctr, Sect Heart Failure & Heart Transplantat, Dept Cardiol, Houston, TX USA
[2] Methodist DeBakey Heart & Vasc Ctr, Cardiovasc Imaging Inst, Houston, TX USA
[3] Hosp San Jose TEC Monterrey, Inst & Ctr Med Tecnol Monterrey, Monterrey, Mexico
关键词
cardiac imaging techniques; computed tomography; heart failure; heart-assist devices; echocardiography; MECHANICAL CIRCULATORY SUPPORT; HEART-FAILURE; COMPUTED-TOMOGRAPHY; EJECTION FRACTION; ECHOCARDIOGRAPHIC EVALUATION; NONINVASIVE ESTIMATION; MAGNETIC-RESONANCE; HEMODYNAMICS; BRIDGE; IMPROVEMENT;
D O I
10.1161/CIRCULATIONAHA.111.040238
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
[No abstract available]
引用
收藏
页码:2265 / 2277
页数:13
相关论文
共 65 条
[1]   A simple method for noninvasive estimation of pulmonary vascular resistance [J].
Abbas, AE ;
Fortuin, FD ;
Schiller, NB ;
Appleton, CP ;
Moreno, CA ;
Lester, SJ .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2003, 41 (06) :1021-1027
[2]   Use of Gated Cardiac Computed Tomography Angiography in the Assessment of Left Ventricular Assist Device Dysfunction [J].
Acharya, Deepak ;
Singh, Satinder ;
Tallaj, Jose A. ;
Holman, William L. ;
George, James F. ;
Kirklin, James K. ;
Pamboukian, Salpy V. .
ASAIO JOURNAL, 2011, 57 (01) :32-37
[3]   Incomplete Recovery of Myocyte Contractile Function Despite Improvement of Myocardial Architecture With Left Ventricular Assist Device Support [J].
Ambardekar, Amrut V. ;
Walker, John S. ;
Walker, Lori A. ;
Cleveland, Joseph C., Jr. ;
Lowes, Brian D. ;
Buttrick, Peter M. .
CIRCULATION-HEART FAILURE, 2011, 4 (04) :425-+
[4]   What is the ideal off-test trial for continuous-flow ventricular-assist-device explantation? Intracircuit back-flow analysis in a mock circulation model [J].
Ando, Masahiko ;
Nishimura, Takashi ;
Takewa, Yoshiaki ;
Ogawa, Daisuke ;
Yamazaki, Kenji ;
Kashiwa, Koichi ;
Kyo, Shunei ;
Ono, Minoru ;
Taenaka, Yoshiyuki ;
Tatsumi, Eisuke .
JOURNAL OF ARTIFICIAL ORGANS, 2011, 14 (01) :70-73
[5]  
ATHANASOULIS T, 1991, J NUCL MED, V32, P255
[6]   Comparison of left ventricular ejection fraction and volumes in heart failure by echocardiography, radionuclide ventriculography and cardiovascular magnetic resonance - Are they interchangeable? [J].
Bellenger, NG ;
Burgess, MI ;
Ray, SG ;
Lahiri, A ;
Coats, AJS ;
Cleland, JGF ;
Pennell, DJ .
EUROPEAN HEART JOURNAL, 2000, 21 (16) :1387-1396
[7]   Successful weaning of a left ventricular assist device implanted for ischemic heart failure [J].
Beurtheret, Sylvain ;
Mordant, Pierre ;
Pavie, Alain ;
Leprince, Pascal .
INTERACTIVE CARDIOVASCULAR AND THORACIC SURGERY, 2010, 11 (04) :507-509
[8]   Left ventricular assist device and drug therapy for the reversal of heart failure [J].
Birks, Emma J. ;
Tansley, Patrick D. ;
Hardy, James ;
George, Robert S. ;
Bowles, Christopher T. ;
Burke, Margaret ;
Banner, Nicholas R. ;
Khaghani, Asghar ;
Yacoub, Magdi H. .
NEW ENGLAND JOURNAL OF MEDICINE, 2006, 355 (18) :1873-1884
[9]  
Catena E, 2007, Minerva Cardioangiol, V55, P247
[10]   Left Ventricular Support by Axial Flow Pump: The Echocardiographic Approach to Device Malfunction [J].
Catena, Emanuele ;
Milazzo, Filippo ;
Montorsi, Emanuela ;
Bruschi, Giuseppe ;
Cannata, Aldo ;
Russo, Claudio ;
Barosi, Alberto ;
Tarelli, Giuseppe ;
Tartara, Paolo ;
Paino, Roberto ;
Vitali, Ettore .
JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2005, 18 (12) :1422.e7-1422.e13