Optical corrosion meter

被引:51
作者
Habib, K
AlSabti, F
AlMazedi, H
机构
[1] Materials Application Department, KISR, Safat 13109
关键词
D O I
10.1016/S0143-8166(96)00147-9
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
In a previous study, a mathematical model relating surface and bulk behaviours of metals in aqueous solution has been developed. The model was established based on principles of holographic interferometry for measuring microsurface dissolution, i.e. mass loss, and on those of electrochemistry for measuring the bulk electronic current, i.e. corrosion current. In the present work, an optical corrosion meter was built based on the above model. The corrosion meter consists of an electrochemical cell in which the sample is immersed in aqueous solution. Furthermore, the corrosion meter has a holographic camera with a thermoplastic film for in situ processing of holograms in order to obtain real-time holographic interferoms of the sample in the electrochemical cell. Results of the present work indicate that optical holography is a very useful technique for measuring the corrosion current density of different alloys in aqueous solutions. As a result, the corrosion current density of aluminium, stainless steel, and low-carbon steel in 1 M KCI, 1 M NaCl, and 1 M NaOH solutions were obtained. A comparison between the corrosion data of samples showed that the corrosion current density of the stainless steel in 1 M NaCl is nearly three-folds higher than that of the aluminium in 1 M KCI and the low-carbon steel in 1 M NaOH. (C) 1997 Elsevier Science Ltd.
引用
收藏
页码:227 / 233
页数:7
相关论文
共 9 条
[1]   TECHNIQUE FOR MEASURING STRESS-CORROSION CRACKING OF METALLIC ELECTRODES IN AQUEOUS-SOLUTIONS [J].
HABIB, K ;
CARMICHAEL, G ;
LAKES, R ;
STWALLEY, W .
CORROSION, 1993, 49 (05) :354-362
[2]   MODEL OF HOLOGRAPHIC-INTERFEROMETRY OF ANODIC-DISSOLUTION OF METALS IN AQUEOUS-SOLUTION [J].
HABIB, K .
OPTICS AND LASERS IN ENGINEERING, 1993, 18 (02) :115-120
[3]  
HABIB K, 1990, P SOC PHOTO-OPT INS, V1230, P293
[4]   NONDESTRUCTIVE EVALUATION OF METALLIC ELECTRODES UNDER CORROSION-FATIGUE CONDITIONS BY HOLOGRAPHIC-INTERFEROMETRY [J].
HABIB, K .
OPTICS AND LASERS IN ENGINEERING, 1995, 23 (01) :65-70
[5]   INITIATION OF STRESS-CORROSION CRACKING OF TI90-AL6-V4 WIRE IN AQUEOUS-SOLUTION - NONDESTRUCTIVE MONITORING BY HOLOGRAPHIC-INTERFEROMETRY [J].
HABIB, K .
OPTICS AND LASERS IN ENGINEERING, 1994, 20 (02) :81-85
[6]   HOLOGRAPHIC-INTERFEROMETRY OF POLARIZED AND LOADED METALLIC ELECTRODES IN AQUEOUS-SOLUTION [J].
HABIB, K .
APPLIED OPTICS, 1990, 29 (13) :1867-1868
[7]  
HABIB K, 1990, EXP TECH PHYS, V38, P535
[8]  
HABIB K, 1992, TECHNIQUES CORROSION
[9]  
HABIB K, 1992, NACE 92