Detection of Bad Data in Phasor Measurement Units Using Distributed Approach

被引:0
|
作者
Thomas, Polly [1 ]
Skariah, Emil Ninan [1 ]
Varghese, Sheena Thomas [1 ]
机构
[1] Saintgits Coll Engn, Dept Elect & Elect Engn, Kottayam, Kerala, India
来源
2017 INNOVATIONS IN POWER AND ADVANCED COMPUTING TECHNOLOGIES (I-PACT) | 2017年
关键词
power system; state estimation; Phasor measurement units; distributed detection; STATIC-STATE ESTIMATION; MODEL;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The chances for presence of bad data in Phasor measurement units are increasing due to complicated power system. Thus the voltage magnitude and phase angle obtained from PMU is no longer accurate. Hence it is important to detect the presence of bad data and identify the PMU which contains the error. In order to implement bad data detection and identification, state estimation is carried out to obtain the true state variables using weighted least square method. In this paper a distributed approach is chosen for identification of bad data. The system network is divided into different areas and the technique is applied to each area separately. The area and the meter which contains error is identified through this method. The system works in MATLAB platform.
引用
收藏
页数:8
相关论文
共 50 条
  • [21] A Substation-Oriented Approach to Optimal Phasor Measurement Units Placement
    Bao, Wei
    Guo, Rui-Peng
    Han, Zhen-Xiang
    Chen, Li-Yue
    Lu, Min
    JOURNAL OF ELECTRICAL ENGINEERING & TECHNOLOGY, 2015, 10 (01) : 18 - 29
  • [22] Detection of Time Spoofing Attacks on GPS Synchronized Phasor Measurement Units
    Mattei, Andrew K.
    Grady, W. Mack
    Caspary, P. Jay
    McBride, Scott A.
    2016 69TH ANNUAL CONFERENCE FOR PROTECTIVE RELAY ENGINEERS (CPRE), 2016,
  • [23] Approach for Multistage Placement of Phasor Measurement Units Based on Stability Criteria
    Kumar, V. Seshadri Sravan
    Thukaram, D.
    IEEE TRANSACTIONS ON POWER SYSTEMS, 2016, 31 (04) : 2714 - 2725
  • [24] Denoising and Detection of Bad Data in Distribution Phasor Measurements Using Filtering, Clustering, and Koopman Mode Analysis
    Gholami, Amir
    Vosughi, Amirkhosro
    Srivastava, Anurag K.
    IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2022, 58 (02) : 1602 - 1610
  • [25] Identification of Interarea Modes From Ambient Data of Phasor Measurement Units Using an Autoregressive Exogenous Model
    Hwang, Jin Kwon
    Shin, Jeonghoon
    IEEE ACCESS, 2021, 9 : 45695 - 45705
  • [26] Precision Measurement System for the Calibration of Phasor Measurement Units
    Georgakopoulos, D.
    Quigg, S.
    2016 CONFERENCE ON PRECISION ELECTROMAGNETIC MEASUREMENTS (CPEM 2016), 2016,
  • [27] A Brief Review of Phasor Measurement Units as Sensors for Smart Grid
    Mohanta, Dusmanta Kumar
    Murthy, Cherukuri
    Roy, Diptendu Sinha
    ELECTRIC POWER COMPONENTS AND SYSTEMS, 2016, 44 (04) : 411 - 425
  • [28] Optimal placement of phasor measurement units for power system observability
    Chakrabarti, Saikat
    Kyriakides, Elias
    IEEE TRANSACTIONS ON POWER SYSTEMS, 2008, 23 (03) : 1433 - 1440
  • [29] A critical review of methods for optimal placement of phasor measurement units
    Johnson, Teena
    Moger, Tukaram
    INTERNATIONAL TRANSACTIONS ON ELECTRICAL ENERGY SYSTEMS, 2021, 31 (03)
  • [30] Optimal Placement of Phasor Measurement Units using Particle Swarm Optimization
    Sadu, Abhinav
    Kumar, Rajesh
    Kavasseri, Rajesh G.
    2009 WORLD CONGRESS ON NATURE & BIOLOGICALLY INSPIRED COMPUTING (NABIC 2009), 2009, : 1707 - +