Model calculation of amplitudes for FT-ICR ion detection in a cylindrical Penning trap

被引:3
|
作者
Kretzschmar, M. [1 ]
机构
[1] Johannes Gutenberg Univ Mainz, Inst Phys, D-55099 Mainz, Germany
来源
APPLIED PHYSICS B-LASERS AND OPTICS | 2012年 / 107卷 / 04期
关键词
CYCLOTRON-RESONANCE DETECTION; MASS-SPECTROMETRY; ELECTRON; DYNAMICS; SIGNAL;
D O I
10.1007/s00340-012-4905-0
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
A Green's function strategy first proposed by Grosshans et al. is used to calculate the electric charges induced by trapped ions on the 4-fold or 8-fold segmented ring electrode of a cylindrical Penning trap. The ions are assumed to move in the central region of the trap where the harmonic approximation holds. The electric charges induced on each detection segment of the ring electrode are obtained in the form of a triple Fourier series with coefficients that describe the contribution of each frequency combination m (+) nu (+)+m (-) nu (-)+m (z) nu (z) as a function of R (+), R (-), Z, where nu (+), nu (-), nu (z) are the characteristic frequencies and R (+), R (-), Z the corresponding amplitudes of the ion motion. The sideband structure is analyzed and the origin of the sidebands is tracked. Finally, single-electrode, differential, and additive detection are discussed.
引用
收藏
页码:1007 / 1017
页数:11
相关论文
共 50 条
  • [11] An online FT-ICR Penning-trap mass spectrometer for the DPS2-F section of the KATRIN experiment
    Heck, M.
    Ascher, P.
    Cakirli, R. B.
    Golzke, H.
    Rodriguez, D.
    Stahl, S.
    Ubieto-Diaz, M.
    Blaum, K.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2014, 757 : 54 - 61
  • [12] STUDY OF ION-MOLECULE REACTIONS BY FT-ICR SPECTROSCOPY
    COMISAROW, M
    PARISOD, G
    MELKA, J
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1979, (APR): : 309 - 309
  • [13] A 4 K FT-ICR cell for infrared ion spectroscopy
    Fritsche, Lukas
    Bach, Andreas
    Miloglyadova, Larisa
    Tsybizova, Alexandra
    Chen, Peter
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2018, 89 (06):
  • [14] An electrically compensated trap designed to eighth order for FT-ICR mass Spectrometry
    Brustkern, Adam M.
    Rempel, Don L.
    Gross, Michael L.
    JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2008, 19 (09) : 1281 - 1285
  • [15] Controlled Ion Ejection from an External Trap for Extended m/z Range in FT-ICR Mass Spectrometry
    Kaiser, Nathan K.
    Savory, Joshua J.
    Hendrickson, Christopher L.
    JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2014, 25 (06) : 943 - 949
  • [16] A novel approach for identification and characterization of glycoproteins using a hybrid linear ion trap/FT-ICR mass spectrometer
    Peterman, Scott M.
    Mulholland, Joseph J.
    Journal of the American Society for Mass Spectrometry, 2006, 17 (02): : 168 - 179
  • [17] A novel approach for identification and characterization of glycoproteins using a hybrid linear ion trap/FT-ICR mass spectrometer
    Peterman, SM
    Mulholland, JJ
    JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2006, 17 (02) : 168 - 179
  • [18] QUADRUPOLE-DETECTION FT-ICR MASS-SPECTROMETRY
    SCHWEIKHARD, L
    LINDINGER, M
    KLUGE, HJ
    INTERNATIONAL JOURNAL OF MASS SPECTROMETRY AND ION PROCESSES, 1990, 98 (01): : 25 - 33
  • [19] On initial ion velocities in MALDI: A novel FT-ICR MS approach
    Tomalova, Iva
    Frankevich, Vladimir
    Zenobi, Renato
    INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 2014, 372 : 51 - 53
  • [20] IMAGE CHARGE-INDUCED ION-CYCLOTRON ORBITAL FREQUENCY-SHIFT FOR ORTHORHOMBIC AND CYLINDRICAL FT-ICR ION TRAPS
    XIANG, XZ
    GROSSHANS, PB
    MARSHALL, AG
    INTERNATIONAL JOURNAL OF MASS SPECTROMETRY AND ION PROCESSES, 1993, 125 (01): : 33 - 43