Design and Implementation of Control System for Range-gated Underwater Laser Imaging

被引:0
|
作者
Ge Wei-long [1 ]
Zhang Xiao-hui [1 ]
Han Hong-wei [1 ]
Hua Liang-hong [2 ]
机构
[1] Naval Univ Engn, Dept Weaponry Engn, Wuhan 430033, Peoples R China
[2] Navy Equipment Dept Beijing, Beijing 100841, Peoples R China
来源
PHOTONICS AND OPTOELECTRONICS MEETINGS (POEM) 2011: OPTOELECTRONIC SENSING AND IMAGING | 2012年 / 8332卷
关键词
Underwater imaging; range-gated; control system; MCU;
D O I
10.1117/12.918859
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
There is currently considerable in developing underwater target detection, the underwater imaging system can be divided into active imaging system and passive system. The main feature of the active imaging system is that they use light sources to illuminate the targets and collect the reflection from targets. The advantages of active imaging system over passive imaging systems are high contrast and without the affection of environment sources. In this article, a range-gated underwater laser imaging system is built, which consists of laser illumination system, photoelectric imaging system and control system. The laser illumination system includes a light-pumped solid state doubled ND-YAG laser(532nm) which laser power and frequency can be adjusted and an optics expanding system of variable ratio. The photoelectric imaging system includes a gated Intensified CCD(ICCD) cameras which ICCD scheduling, gate width, delay time and gain can be adjusted and a optics received system of variable ratio. In order to acquire effectual target image using range-gated underwater laser imaging system, appropriate control parameters that include laser power and frequency, ICCD scheduling, gate width, delay time and gain, optics expanding system ratio and optics received system ratio must be given accurately. A control system which used C8051F320 and C8051F040 (MCU) as the core is designed, the control system can effectively control seven parameters that given above. The construction of software and hardware of the control system is introduced. And target image of underwater distance 25 m and 40m is given, Experimental results showed that the control system has high control precision, safe and stable operation and good speed adjusting performance can be achieved. It can be satisfied to apply to underwater target detection.
引用
收藏
页数:8
相关论文
共 50 条
  • [1] Design and implementation of Range-gated Underwater Laser Imaging System
    Ge Wei-long
    Zhang Xiao-hui
    SELECTED PAPERS FROM CONFERENCES OF THE PHOTOELECTRONIC TECHNOLOGY COMMITTEE OF THE CHINESE SOCIETY OF ASTRONAUTICS: OPTICAL IMAGING, REMOTE SENSING, AND LASER-MATTER INTERACTION 2013, 2014, 9142
  • [2] Underwater Range-gated Laser Imaging System Design With Video Enhancement Processing
    Ning Yu
    Li Li
    Qiu Su
    Jin Weiqi
    He Kang
    Shi Yan
    Wang Xia
    2013 2ND INTERNATIONAL SYMPOSIUM ON INSTRUMENTATION AND MEASUREMENT, SENSOR NETWORK AND AUTOMATION (IMSNA), 2013, : 760 - 763
  • [3] Range-gated underwater laser imaging system based on intensified gate imaging technology
    Jin Weiqi
    Cao Fengmei
    Wang Xia
    Liu Guangrong
    Huang Youwei
    Qi Huaichuan
    Shen Fei
    INTERNATIONAL SYMPOSIUM ON PHOTOELECTRONIC DETECTION AND IMAGING 2007: PHOTOELECTRONIC IMAGING AND DETECTION, 2008, 6621
  • [4] A handheld laser range-gated imaging instrument for underwater rescue and observation
    Zhang Qianghui
    Jin Weiqi
    Qiu Su
    Li Li
    2011 INTERNATIONAL CONFERENCE ON OPTICAL INSTRUMENTS AND TECHNOLOGY: OPTOELECTRONIC IMAGING AND PROCESSING TECHNOLOGY, 2011, 8200
  • [5] Nonuniformly Illuminated Image Enhancement Based on Range-gated Underwater Imaging System
    Li, Hailan
    Wang, Xia
    Bai, Tingzhu
    Jin, Weiqi
    Huang, Youwei
    Ding, Kun
    2008 INTERNATIONAL CONFERENCE ON OPTICAL INSTRUMENTS AND TECHNOLOGY: OPTICAL SYSTEMS AND OPTOELECTRONIC INSTRUMENTS, 2009, 7156
  • [6] Range-gated system design based-on CPLD of laser active imaging
    Wang Dongmei
    ISTM/2007: 7TH INTERNATIONAL SYMPOSIUM ON TEST AND MEASUREMENT, VOLS 1-7, CONFERENCE PROCEEDINGS, 2007, : 1478 - 1480
  • [7] Analysis on the Influences of Range-gated Underwater Laser Imaging System Parameters on the Signal to Noise Ratio
    Ge Wei-long
    Hua Liang-hong
    Han Hong-wei
    INTERNATIONAL SYMPOSIUM ON PHOTOELECTRONIC DETECTION AND IMAGING 2013: LASER SENSING AND IMAGING AND APPLICATIONS, 2013, 8905
  • [8] Experimental study on underwater range-gated imaging system pulse and gate control coordination strategy
    Liu Wei
    Li Qi
    Hao Ge-yang
    Wu Guo-jun
    Lv Pei
    OCEAN OPTICS AND INFORMATION TECHNOLOGY, 2018, 10850
  • [9] A novel application of range-gated underwater laser imaging system (ULIS) in near-target turbid medium
    Tan, CS
    Seet, G
    Sluzek, A
    He, DM
    OPTICS AND LASERS IN ENGINEERING, 2005, 43 (09) : 995 - 1009
  • [10] Research on range-gated laser active imaging seeker
    You, Mu
    Wang, PengHui
    Tan, DongJie
    INTERNATIONAL SYMPOSIUM ON PHOTOELECTRONIC DETECTION AND IMAGING 2013: LASER SENSING AND IMAGING AND APPLICATIONS, 2013, 8905