Electrochemical Impedance Spectroscopy on Interdigitated Gold Microelectrodes for Glycosylated Human Serum Albumin Characterization

被引:19
作者
Bohli, Nadra [1 ]
Chammem, Hanen [1 ]
Meilhac, Olivier [2 ]
Mora, Laurence [3 ]
Abdelghani, Adnane [1 ]
机构
[1] Carthage Univ, Natl Inst Appl Sci & Technol, UR17ES22, Unite Rech Nanobiotechnol & Valorisat Phytoressou, Tunis 1054, Tunisia
[2] Univ La Reunion, Diabet Atherothrombose Therapies Reunion Ocean In, INSERM, CYROI,U1188, F-97490 St Clothilde, Reunion, France
[3] Univ Paris 13, Lab Vasc Transit Sci, INSERM, Inst Galilee,U1148, F-93430 Villetaneuse, France
关键词
Biosensor; dielectric permittivity; electrochemical impedance spectroscopy; glycated albumin; interdigitated gold microelectrodes; surface plasmon resonance; GLYCATED HEMOGLOBIN; DISEASE;
D O I
10.1109/TNB.2017.2752693
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Glycosylated albumin is considered as a potentially accurate indicator of shorter-term average glucose concentration compared with the current standard HbA1c and as such, it is attracting the interest of the scientific community as a possible diagnosis marker for diabetic patients. The purpose of this paper is to achieve a better understanding of the glycation effect of albumin on its electrochemical properties. That is done through the use of Interdigitated gold microelectrodes (IDGE) as support in a label free impedimetric immunosensor for the detection of human serum albumin detection in glycated (GA) and non-glycated (HSA) form. Anti-human serum albumin, a mono-clonalantibody, was physisorbedon the surface of IDGEand used as a HSA/GA bioreceptor. Electrochemical impedance spectroscopy, cyclic voltammetry, and surface plasmon resonance imaging (SPRi) were used for the characterization of the grafted layers onto the gold surface. A detection range from 1 to 401 ng/mL of non glycated HSA antigen in phosphate buffered saline buffer was obtained with the impedance spectroscopy technique. The experiment led to the observation of a significant impedance difference between the glycated and non-glycated antigen of HSA. SPRi measurements confirmed these findings and allowed us to suggest an increase of the dielectric permittivity for human serum albumin upon glycation.
引用
收藏
页码:676 / 681
页数:6
相关论文
共 34 条
[1]   Glycated albumin: An overview of the In Vitro models of an In Vivo potential disease marker [J].
Arasteh A. ;
Farahi S. ;
Habibi-Rezaei M. ;
Moosavi-Movahedi A.A. .
Journal of Diabetes & Metabolic Disorders, 13 (1)
[2]   Recent advances in detection of AGEs: Immunochemical, bioanalytical and biochemical approaches [J].
Ashraf, Jalaluddin Mohd. ;
Ahmad, Saheem ;
Choi, Inho ;
Ahmad, Nashrah ;
Farhan, Mohd. ;
Tatyana, Godovikova ;
Shahab, Uzma .
IUBMB LIFE, 2015, 67 (12) :897-913
[3]  
Baccar H., 2014, J NANOMED NANOTECHNO, V5, P243
[4]   A disposable electrochemical sensor based on protein G for High-Density Lipoprotein (HDL) detection [J].
Chammem, H. ;
Hafaid, I. ;
Bohli, N. ;
Garcia, A. ;
Meilhac, O. ;
Abdelghani, A. ;
Mora, L. .
TALANTA, 2015, 144 :466-473
[5]  
Chammem H., 2014, J. Biomater. Nanobiotechnol, V5, P153, DOI DOI 10.4236/JBNB.2014.53018
[6]   Effects of oxidative modifications induced by the glycation of bovine serum albumin on its structure and on cultured adipose cells [J].
Chesne, Serge ;
Rondeau, Philippe ;
Armenta, Sergio ;
Bourdon, Emmanuel .
BIOCHIMIE, 2006, 88 (10) :1467-1477
[7]   Fabrication of Potentiometric Enzymatic Glucose Biosensor Based on Graphene and Magnetic Beads [J].
Chou, Jung-Chuan ;
Chen, Ruei-Ting ;
Liao, Yi-Hung ;
Lin, Jyun-Wun ;
Lin, Chin-Yi ;
Jhang, Chiung-Yun ;
Chou, Hsueh-Tao .
IEEE SENSORS JOURNAL, 2015, 15 (09) :5278-5284
[8]   Characterization of Paracetamol Binding with Normal and Glycated Human Serum Albumin Assayed by a New Electrochemical Method [J].
Daneshegar, Parandis ;
Moosavi-Movahedi, Ali Akbar ;
Norouzi, Parviz ;
Ganjali, Mohammad Reza ;
Farhadi, Mohammad ;
Sheibani, Nader .
JOURNAL OF THE BRAZILIAN CHEMICAL SOCIETY, 2012, 23 (02) :315-321
[9]  
Furusyo N., BIOCH BIOPHYS ACTA G, V1830, P5509
[10]   Effect of electrical conditions on an impedimetric immunosensor based on a modified conducting polypyrrole [J].
Hafaid, Imen ;
Chebil, Syrine ;
Korri-Youssoufi, Hafsa ;
Bessueille, Francois ;
Errachid, Abdelhamid ;
Sassi, Zina ;
Ali, Zulfiqur ;
Abdelghani, Adnane ;
Jaffrezic-Renault, Nicole .
SENSORS AND ACTUATORS B-CHEMICAL, 2010, 144 (01) :323-331