Performance evaluation of air flow and thermal comfort in the room with Wind-Catcher using different CFD techniques under neutral Atmospheric Boundary Layer

被引:12
作者
Kabir, Ijaz Fazil Syed Ahmed [1 ]
Kanagalingam, Sivamoorthy [1 ]
Safiyullah, Ferozkhan [2 ]
机构
[1] Nanyang Technol Univ, Coll Engn, Sch Mech & Aerosp Engn, 50 Nanyang Ave, Singapore 639798, Singapore
[2] Univ Teknol PETRONAS, Dept Mech Engn, Tronoh 31750, Malaysia
来源
LEVERAGING ENERGY TECHNOLOGIES AND POLICY OPTIONS FOR LOW CARBON CITIES | 2017年 / 143卷
关键词
Wind-Catcher; Thermal Comfort; Atmospheric Boundary Layer; VENTILATION; SIMULATION; TOWER; SYSTEMS; MODEL; HOT;
D O I
10.1016/j.egypro.2017.12.671
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Energy usage in buildings using conventional Heat Ventilation Air Conditioning (HVAC) systems can be considerably reduced on using natural ventilation systems like wind catcher. In addition to high energy consumptions in conventional HVAC, other disadvantages include ozone layer depletion due to CFCs emitted and also cost involved in installation and maintenance. Purpose of this study was to investigate the airflow and thermal comfort analyses of existing common wind catcher design in the city of Yazd using computational fluid dynamics (CFD) technique. In order to have more realistic analysis, neutral homogenous atmospheric boundary layer (ABL) was created at the inlet. Standard k-e turbulence model was used since equations for creating ABL were more related to this model. 3D CFD analysis was performed using both ANSYS FLUENT and OPENFOAM. Thermal comfort analysis was evaluated based on ASHRAE standard 55. (C) 2017 The Authors. Published by Elsevier Ltd.
引用
收藏
页码:199 / 203
页数:5
相关论文
共 23 条
  • [1] Awbi H. B., 2002, P WORLD REN EN C 7
  • [2] Experimental investigation of new designs of wind towers
    Bahadori, M. N.
    Mazidi, M.
    Dehghani, A. R.
    [J]. RENEWABLE ENERGY, 2008, 33 (10) : 2273 - 2281
  • [3] CFD simulation of the atmospheric boundary layer: wall function problems
    Blocken, Bert
    Stathopoulos, Ted
    Carmeliet, Jan
    [J]. ATMOSPHERIC ENVIRONMENT, 2007, 41 (02) : 238 - 252
  • [4] Climatic analysis of a passive cooling technology for the built environment in hot countries
    Calautit, John Kaiser
    Hughes, Ben Richard
    Nasir, Diana S. N. M.
    [J]. APPLIED ENERGY, 2017, 186 : 321 - 335
  • [5] CFD Simulation and Optimisation of a Low Energy Ventilation and Cooling System
    Calautit, John Kaiser
    O'Connor, Dominic
    Sofotasiou, Polytimi
    Hughes, Ben Richard
    [J]. COMPUTATION, 2015, 3 (02) : 128 - 149
  • [6] Comparison between evaporative cooling and a heat pipe assisted thermal loop for a commercial wind tower in hot and dry climatic conditions
    Calautit, John Kaiser
    Chaudhry, Hassam Nasarullah
    Hughes, Ben Richard
    Ghani, Saud Abdul
    [J]. APPLIED ENERGY, 2013, 101 : 740 - 755
  • [7] Calautit John Kaiser S., 2012, APPL ENERGY
  • [8] ELMUALIM A.A., 2002, International Journal of Ventilation, V1, P53, DOI 10.1080/14733315.2002.11683622
  • [9] Elmualim Abbas, 2001, EVALUATING PERFORMAN
  • [10] Fanger PO, 1970, THERMAL COMFORT