A Noninvasive Assessment of Flow Based on Contrast Dispersion in Computed Tomography Angiography: A Computational and Experimental Phantom Study

被引:2
作者
Eslami, Parastou [1 ]
Seo, Jung-Hee [2 ]
Rahsepar, Amir Ali [3 ]
Shafique, Asim [4 ]
Rollison, Shirley F. [5 ]
Lardo, Albert C. [6 ]
Mittal, Rajat [2 ,7 ]
Chen, Marcus Y. [5 ]
机构
[1] Harvard Med Sch, Massachusetts Gen Hosp, Dept Radiol, 165 Cambridge St,Suite 400, Boston, MA 02114 USA
[2] Johns Hopkins Univ, Dept Mech Engn, Baltimore, MD 21218 USA
[3] Johns Hopkins Univ, Sch Med, Dept Med, Div Cardiol, Baltimore, MD 21205 USA
[4] Rowan Univ, Sch Osteopath Med, Stratford, NJ 08084 USA
[5] Natl Heart Lung & Blood Inst NHLBI, NIH, Bethesda, MD USA
[6] Johns Hopkins Univ, Dept Biomed Engn, Baltimore, MD 21218 USA
[7] Johns Hopkins Univ, Dept Med, Div Cardiol, Baltimore, MD 21287 USA
来源
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME | 2022年 / 144卷 / 09期
关键词
coronary computed tomography; transluminal attenuation gradient; transluminal flow encoding; time density; contrast agent; noninvasive flow rate; TRANSLUMINAL ATTENUATION GRADIENT; CORONARY-ARTERY STENOSES; CT ANGIOGRAPHY; DIASTOLIC FUNCTION; VALIDATION; VELOCITY; RESERVE; AGE;
D O I
10.1115/1.4053997
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Transluminal attenuation gradient (TAG), defined as the gradient of the contrast agent attenuation drop along the vessel, is an imaging biomarker that indicates stenosis in the coronary arteries. The transluminal attenuation flow encoding (TAFE) equation is a theoretical platform that quantifies blood flow in each coronary artery based on computed tomography angiography (CTA) imaging. This formulation couples TAG (i.e., contrast dispersion along the vessel) with fluid dynamics. However, this theoretical concept has never been validated experimentally. The aim of this proof-of-principle phantom study is to validate TAFE based on CTA imaging. Dynamic CTA images were acquired every 0.5 s. The average TAFE estimated flow rates were compared against four predefined pump values in a straight (20, 25, 30, 35, and 40 ml/min) and a tapered phantom (25, 35, 45, and 55 ml/min). Using the TAFE formulation with no correction, the flow rates were underestimated by 33% and 81% in the straight and tapered phantoms, respectively. The TAFE formulation was corrected for imaging artifacts focusing on partial volume averaging and radial variation of contrast enhancement. After corrections, the flow rates estimated in the straight and tapered phantoms had an excellent Pearson correlation of r = 0.99 and 0.87 (p < 0.001), respectively, with only a 0.6%+/- 0.2 mL/min difference in estimation of the flow rate. In this proof-of-concept phantom study, we corrected the TAFE formulation and showed a good agreement with the actual pump values. Future clinical validations are needed for feasibility of TAFE in clinical use.
引用
收藏
页数:10
相关论文
共 25 条
[1]   Association of coronary plaque burden with fractional flow reserve: should we keep attempting to derive physiology from anatomy? [J].
Abd, Thura T. ;
George, Richard T. .
CARDIOVASCULAR DIAGNOSIS AND THERAPY, 2015, 5 (01) :67-70
[2]  
Appel A., 1968, P SPRING JOINT COMP, P37
[3]   Intra-vascular blood velocity and volumetric flow rate calculated from dynamic 4D CT angiography using a time of flight technique [J].
Barfett, Joseph John ;
Velauthapillai, Nivethan ;
Fierstra, Jorn ;
Crawley, Adrian ;
Coolens, Catherine ;
Crean, Andrew ;
Jaskolka, Jeff ;
Dufort, Paul ;
Krings, Timo ;
Mikulis, David .
INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2014, 30 (07) :1383-1392
[4]   Magnetic resonance and computed tomographic evaluation of congenital heart disease [J].
Boxt, LM .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2004, 19 (06) :827-847
[6]   Active contours without edges [J].
Chan, TF ;
Vese, LA .
IEEE TRANSACTIONS ON IMAGE PROCESSING, 2001, 10 (02) :266-277
[7]   Diagnostic performance of intracoronary gradient-based methods by coronary computed tomography angiography for the evaluation of physiologically significant coronary artery stenoses: a validation study with fractional flow reserve [J].
Choi, Jin-Ho ;
Koo, Bon-Kwon ;
Yoon, Yeonyee E. ;
Min, James K. ;
Song, Young-Bin ;
Hahn, Joo-Yong ;
Choi, Seung-Hyuk ;
Gwon, Hyeon-Cheol ;
Choe, Yeon Hyeon .
EUROPEAN HEART JOURNAL-CARDIOVASCULAR IMAGING, 2012, 13 (12) :1001-1007
[8]   LUMEN DIAMETER OF NORMAL HUMAN CORONARY-ARTERIES - INFLUENCE OF AGE, SEX, ANATOMIC VARIATION, AND LEFT-VENTRICULAR HYPERTROPHY OR DILATION [J].
DODGE, JT ;
BROWN, BG ;
BOLSON, EL ;
DODGE, HT .
CIRCULATION, 1992, 86 (01) :232-246
[9]   Computational Study of Computed Tomography Contrast Gradients in Models of Stenosed Coronary Arteries [J].
Eslami, Parastou ;
Seo, Jung-Hee ;
Rahsepar, Amir Ali ;
George, Richard ;
Lardo, Albert C. ;
Mittal, Rajat .
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 2015, 137 (09)
[10]  
Hoffmann U, 2017, CIRCULATION, V135, P2320, DOI 10.1161/CIRCULATIONAHA.116.024360