Correcting spherical aberrations in a biospecimen using a transmissive liquid crystal device in two-photon excitation laser scanning microscopy

被引:22
作者
Tanabe, Ayano [1 ,2 ,3 ]
Hibi, Terumasa [1 ,2 ]
Ipponjima, Sari [1 ,2 ]
Matsumoto, Kenji [3 ]
Yokoyama, Masafumi [3 ]
Kurihara, Makoto [3 ]
Hashimoto, Nobuyuki [3 ]
Nemotoa, Tomomi [1 ,2 ]
机构
[1] Hokkaido Univ, Res Inst Elect Sci, Kita Ward, Sapporo, Hokkaido 0010020, Japan
[2] Hokkaido Univ, Grad Sch Informat Sci & Technol, Kita Ward, Sapporo, Hokkaido 0600814, Japan
[3] Citizen Holdings Co Ltd, Tokorozawa, Saitama 3598511, Japan
关键词
adaptive optics; liquid crystals; phase modulation; scanning microscopy; aberrations; ADAPTIVE OPTICS; FLUORESCENCE MICROSCOPY; LATERAL RESOLUTION; ADULT CORTEX; SYSTEMS; DEPTH; FIELD; BEAM; LENS;
D O I
10.1117/1.JBO.20.10.101204
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Two-photon excitation laser scanning microscopy has enabled the visualization of deep regions in a biospecimen. However, refractive-index mismatches in the optical path cause spherical aberrations that degrade spatial resolution and the fluorescence signal, especially during observation at deeper regions. Recently, we developed transmissive liquid-crystal devices for correcting spherical aberration without changing the basic design of the optical path in a conventional laser scanning microscope. In this study, the device was inserted in front of the objective lens and supplied with the appropriate voltage according to the observation depth. First, we evaluated the device by observing fluorescent beads in single-and two-photon excitation laser scanning microscopes. Using a 25x water-immersion objective lens with a numerical aperture of 1.1 and a sample with a refractive index of 1.38, the device recovered the spatial resolution and the fluorescence signal degraded within a depth of +/- 0.6 mm. Finally, we implemented the device for observation of a mouse brain slice in a two-photon excitation laser scanning microscope. An optical clearing reagent with a refractive index of 1.42 rendered the fixed mouse brain transparent. The device improved the spatial resolution and the yellow fluorescent protein signal within a depth of 0-0.54 mm. (C) The Authors. Published by SPIE under a Creative Commons Attribution 3.0 Unported License. Distribution or reproduction of this work in whole or in part requires full attribution of the original publication, including its DOI.
引用
收藏
页数:11
相关论文
共 28 条
  • [1] [Anonymous], NATURE
  • [2] A Rapid Optical Clearing Protocol Using 2,2'-Thiodiethanol for Microscopic Observation of Fixed Mouse Brain
    Aoyagi, Yuka
    Kawakami, Ryosuke
    Osanai, Hisayuki
    Hibi, Terumasa
    Nemoto, Tomomi
    [J]. PLOS ONE, 2015, 10 (01):
  • [3] Measurement and correction of in vivo sample aberrations employing a nonlinear guide-star in two-photon excited fluorescence microscopy
    Aviles-Espinosa, Rodrigo
    Andilla, Jordi
    Porcar-Guezenec, Rafael
    Olarte, Omar E.
    Nieto, Marta
    Levecq, Xavier
    Artigas, David
    Loza-Alvarez, Pablo
    [J]. BIOMEDICAL OPTICS EXPRESS, 2011, 2 (11): : 3135 - 3149
  • [4] Aberration correction for confocal imaging in refractive-index-mismatched media
    Booth, MJ
    Neil, MAA
    Wilson, T
    [J]. JOURNAL OF MICROSCOPY, 1998, 192 : 90 - 98
  • [5] In-line FINCH super resolution digital holographic fluorescence microscopy using a high efficiency transmission liquid crystal GRIN lens
    Brooker, Gary
    Siegel, Nisan
    Rosen, Joseph
    Hashimoto, Nobuyuki
    Kurihara, Makoto
    Tanabe, Ayano
    [J]. OPTICS LETTERS, 2013, 38 (24) : 5264 - 5267
  • [6] Fen G., 2000, NEURON, V28, P41
  • [7] GIBSON SF, 1992, J OPT SOC AM A, V9, P154
  • [8] Long-term dendritic spine stability in the adult cortex
    Grutzendler, J
    Kasthuri, N
    Gan, WB
    [J]. NATURE, 2002, 420 (6917) : 812 - 816
  • [9] Scale: a chemical approach for fluorescence imaging and reconstruction of transparent mouse brain
    Hama, Hiroshi
    Kurokawa, Hiroshi
    Kawano, Hiroyuki
    Ando, Ryoko
    Shimogori, Tomomi
    Noda, Hisayori
    Fukami, Kiyoko
    Sakaue-Sawano, Asako
    Miyawaki, Atsushi
    [J]. NATURE NEUROSCIENCE, 2011, 14 (11) : 1481 - U166
  • [10] Improvement of lateral resolution and extension of depth of field in two-photon microscopy by a higher-order radially polarized beam
    Ipponjima, Sari
    Hibi, Terumasa
    Kozawa, Yuichi
    Horanai, Hibiki
    Yokoyama, Hiroyuki
    Sato, Shunichi
    Nemoto, Tomomi
    [J]. MICROSCOPY, 2014, 63 (01) : 23 - 32