Shortened breath-hold contrast-enhanced MRI of the liver using a new parallel imaging technique, CAIPIRINHA (controlled aliasing in parallel imaging results in higher acceleration): a comparison with conventional GRAPPA technique

被引:12
作者
Ogawa, Masaki [1 ]
Kawai, Tatsuya [1 ]
Kan, Hirohito [1 ]
Kobayashi, Susumu [2 ]
Akagawa, Yoshihiro [2 ]
Suzuki, Kazushi [1 ]
Nojiri, Shunsuke [3 ]
Ozawa, Yoshiyuki [1 ]
Shibamoto, Yuta [1 ]
机构
[1] Nagoya City Univ, Grad Sch Med Sci, Dept Radiol, Mizuho Ku, Nagoya, Aichi 4678601, Japan
[2] Toyokawa City Hosp, Dept Radiol, Toyokawa, Japan
[3] Nagoya City Univ, Grad Sch Med Sci, Dept Gastroenterol & Metab, Nagoya, Aichi, Japan
来源
ABDOMINAL IMAGING | 2015年 / 40卷 / 08期
关键词
Controlled aliasing in parallel imaging results in higher acceleration (CAIPIRINHA); Short breath hold; 3-Dimensional volumetric interpolated breath-hold examination (3D-VIBE); Parallel imaging technique; High acceleration factor (AF); Gadoxetic acid-enhanced liver MRI; QUALITY; PHASE; VIBE; CT;
D O I
10.1007/s00261-015-0491-z
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
We examined whether the shortened breath-hold 3-dimensional volumetric interpolated breath-hold examination (3D-VIBE) sequence for high acceleration factor (AF) using the controlled aliasing in parallel imaging results in higher acceleration (CAIPIRINHA) could substitute for the conventional sequence using generalized autocalibrating partially parallel acquisition (GRAPPA) in patients undergoing routine gadoxetic acid-enhanced liver MRI. Thirty patients with clinically suspected focal liver lesions were scanned using 3D-VIBE sequences with GRAPPA with AF = 2 and AF = 4 and CAIPIRINHA with AF = 4 (acquisition times: 21, 14, and 12 s, respectively) during the hepatobiliary phase. Visual evaluations using a 3- or 5-point scale and signal-to-noise ratio (SNR) analysis were performed for the 3 sequences. For CAIPIRINHA with AF = 4, there was significantly less image noise in both visual evaluation and SNR analysis and fewer parallel imaging artifacts than for GRAPPA with AF = 4 (P < 0.0005); it was equal to GRAPPA with AF = 2 and had fewer motion artifacts than GRAPPA with AF = 2 and 4 (P < 0.0012). The liver edge sharpness and hepatic vessel clarity, lesion conspicuity, and overall image quality were rated significantly higher with CAIPIRINHA with AF = 4 than GRAPPA with AF = 2 and AF = 4 (P < 0.009). For GRAPPA with AF = 4, lesion conspicuity and overall image quality were rated significantly lower than for GRAPPA with AF = 2 (P < 0.012). The shortened breath-hold 3D-VIBE sequence using the new CAIPIRINHA technique with a high AF of 4 was superior to the conventional GRAPPA sequence. The shortened breath-hold sequence using GRAPPA with a high AF of 4 worsened the image quality and lesion conspicuity.
引用
收藏
页码:3091 / 3098
页数:8
相关论文
共 20 条
  • [1] Detection of hepatocellular carcinoma by Gd-EOB-DTPA-enhanced liver MRI: Comparison with triple phase 64 detector row helical CT
    Akai, Hiroyuki
    Kiryu, Shigeru
    Matsuda, Izuru
    Satou, Jirou
    Takao, Hidemasa
    Tajima, Taku
    Watanabe, Yasushi
    Imamura, Hiroshi
    Kokudo, Norihiro
    Akahane, Masaaki
    Ohtomo, Kuni
    [J]. EUROPEAN JOURNAL OF RADIOLOGY, 2011, 80 (02) : 310 - 315
  • [2] Controlled aliasing in parallel imaging results in higher acceleration (CAIPIRINHA) for multi-slice imaging
    Breuer, FA
    Blaimer, M
    Heidemann, RM
    Mueller, MF
    Griswold, MA
    Jakob, PM
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2005, 53 (03) : 684 - 691
  • [3] Measurement of signal-to-noise ratios in MR images: Influence of multichannel coils, parallel imaging, and reconstruction filters
    Dietrich, Olaf
    Raya, Jose G.
    Reeder, Scott B.
    Reiser, Maximilian F.
    Schoenberg, Stefan O.
    [J]. JOURNAL OF MAGNETIC RESONANCE IMAGING, 2007, 26 (02) : 375 - 385
  • [4] Parallel MR imaging: A user's guide
    Glockner, JF
    Hu, HH
    Stanley, DW
    Angelos, L
    King, K
    [J]. RADIOGRAPHICS, 2005, 25 (05) : 1279 - 1297
  • [5] Kitoh Yoshihiro, 2012, Nihon Hoshasen Gijutsu Gakkai Zasshi, V68, P1269
  • [6] Hepatic MR imaging with a dynamic contrast-enhanced isotropic volumetric interpolated breath-hold examination: Feasibility, reproducibility, and technical quality
    Lee, VS
    Lavelle, MT
    Rofsky, NM
    Laub, G
    Thomasson, DM
    Krinsky, GA
    Weinreb, JC
    [J]. RADIOLOGY, 2000, 215 (02) : 365 - 372
  • [7] CAIPIRINHA-VIBE and GRAPPA-VIBE for Liver MRI at 1.5 T: A Comparative In Vivo Patient Study
    Morani, Ajaykumar C.
    Vicens, Rafael A.
    Wei, Wei
    Gupta, Shiva
    Vikram, Raghu
    Balachandran, Aparna
    Reed, Brandy J.
    Ma, Jingfei
    Qayyum, Aliya
    Szklaruk, Janio
    [J]. JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2015, 39 (02) : 263 - 269
  • [8] Motulsky H, 1997, T INTUITIVE BIOSTATI, P196
  • [9] Diagnosis of Colorectal Hepatic Metastases: Comparison of Contrast-Enhanced CT, Contrast-Enhanced US, Superparamagnetic Iron Oxide-Enhanced MRI, and Gadoxetic Acid-Enhanced MRI
    Muhi, Ali
    Ichikawa, Tomoaki
    Motosugi, Utaroh
    Sou, Hironobu
    Nakajima, Hiroto
    Sano, Katsuhiro
    Sano, Mika
    Kato, Satoshi
    Kitamura, Takatoshi
    Fatima, Zareen
    Fukushima, Kimiyo
    Iino, Hiroshi
    Mori, Yoshiyuki
    Fujii, Hideki
    Araki, Tsutomu
    [J]. JOURNAL OF MAGNETIC RESONANCE IMAGING, 2011, 34 (02) : 326 - 335
  • [10] Usefulness of Controlled Aliasing in Parallel Imaging Results in Higher Acceleration in Gadoxetic Acid-Enhanced Liver Magnetic Resonance Imaging to Clarify the Hepatic Arterial Phase
    Park, Yang Shin
    Lee, Chang Hee
    Kim, In Seong
    Kiefer, Berthold
    Woo, Seung Tae
    Kim, Kyeong Ah
    Park, Cheol Min
    [J]. INVESTIGATIVE RADIOLOGY, 2014, 49 (03) : 183 - 188