Optimisation of an electrochemical impedance spectroscopy aptasensor by exploiting quartz crystal microbalance with dissipation signals

被引:50
|
作者
Formisano, Nello [1 ]
Jolly, Pawan [1 ]
Bhalla, Nikhil [1 ]
Cromhout, Mary [2 ]
Flanagan, Shane P. [2 ]
Fogel, Ronen [2 ]
Limson, Janice L. [2 ]
Estrela, Pedro [1 ]
机构
[1] Univ Bath, Dept Elect & Elect Engn, Bath BA2 7AY, Avon, England
[2] Rhodes Univ, Biotechnol Innovat Ctr, ZA-6140 Grahamstown, South Africa
关键词
Electrochemical Impedance Spectroscopy; Quartz Crystal Microbalance with Dissipation; DNA aptamer; Prostate cancer; PROSTATE-SPECIFIC ANTIGEN; LABEL-FREE DETECTION; VISCOELASTIC PROPERTIES; DNA APTAMER; BIOSENSOR; CANCER; FILM;
D O I
10.1016/j.snb.2015.05.049
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The response of an Electrochemical Impedance Spectroscopy (EIS) sensor using DNA aptamers is affected by many factors, such as DNA density, charge and conformational changes upon DNA-target binding, and buffer conditions. We report here for the first time on the optimisation of an EIS aptamer-based sensor by using Quartz Crystal Microbalance with Dissipation mode (QCM-D). As a case study, we employed a DNA aptamer against Prostate-Specific Antigen (PSA). PSA detection was achieved by functionalising the gold sensor surface via thiol chemistry with different ratios of thiolated-DNA aptamer and 6-mercapto-1-hexanol (MCH) used as spacer molecules. PSA binding efficiency can be monitored by measuring QCM-D signals which not only provide information about the mass of PSA bound on the sensor surface, but also crucial information about the aptamer conformation and layer hydration. Data generated through QCM-D analysis provided the optimal conditions in terms of aptamer/MCH ratio to maximise the PSA binding. The ratio of 1:200 for DNA aptamer/spacer molecule was found to be optimal for ensuring maximum PSA binding. However, this study showed how a maximum analyte binding does not necessarily correspond to a maximum EIS response, which revealed to be enhanced if a ratio of 1:100 for DNA aptamer/spacer molecule was used. Moreover, by monitoring the QCM-D signal, for the first time, a value of the dissociation constant (K-d), equal to 37 nM, was found for the PSA DNA aptamer towards its target. The combination of QCM-D with EIS techniques provides further insight into the effects of mass loading and charge effects that govern the response of an EIS aptasensor, serving as a valuable support for future EIS aptamer-based applications. (C) 2015 Elsevier B.V. All rights reserved.
引用
收藏
页码:369 / 375
页数:7
相关论文
共 50 条
  • [1] Convergence of Dissipation and Impedance Analysis of Quartz Crystal Microbalance Studies
    Zhang, Yaozhong
    Du, Binyang
    Chen, Xinan
    Ma, Hongwei
    ANALYTICAL CHEMISTRY, 2009, 81 (02) : 642 - 648
  • [2] Interaction of BSA protein with copper evaluated by electrochemical impedance spectroscopy and quartz crystal microbalance
    Pinto, Edilson M.
    Soares, David M.
    Brett, Christopher M. A.
    ELECTROCHIMICA ACTA, 2008, 53 (25) : 7460 - 7466
  • [3] Acoustic quantification of ATP using a quartz crystal microbalance with dissipation
    Cengiz Oezalp, Veli
    ANALYST, 2011, 136 (23) : 5046 - 5050
  • [4] Ochratoxin A Detection by an Immunosensor Using Impedance Spectroscopy Coupled with Quartz Crystal Microbalance
    Cheap, H.
    Sanchez, M.
    Vivier, V.
    Perrot, H.
    Marty, J. L.
    SENSOR LETTERS, 2011, 9 (06) : 2312 - 2315
  • [5] First characterization of a biosensor for large DNA molecules using quartz crystal microbalance and impedance spectroscopy
    Marques de Oliveira, I. A.
    Barreiros dos Santos, M.
    Rodriguez-Segui, S.
    Gomes, M. T. S. R.
    Eritja, R.
    Samitier, J.
    Errachid, A.
    TRANSDUCERS '07 & EUROSENSORS XXI, DIGEST OF TECHNICAL PAPERS, VOLS 1 AND 2, 2007,
  • [6] Electrodeposition of copper from spent Li-ion batteries by electrochemical quartz crystal microbalance and impedance spectroscopy techniques
    Celante, V. G.
    Freitas, M. B. J. G.
    JOURNAL OF APPLIED ELECTROCHEMISTRY, 2010, 40 (02) : 233 - 239
  • [7] Electrodeposition of copper from spent Li-ion batteries by electrochemical quartz crystal microbalance and impedance spectroscopy techniques
    V. G. Celante
    M. B. J. G. Freitas
    Journal of Applied Electrochemistry, 2010, 40 : 233 - 239
  • [8] Strategy of red blood cells immobilisation onto a gold electrode: Characterization by electrochemical impedance spectroscopy and quartz crystal microbalance
    Ribaut, C.
    Reybier, K.
    Torbiero, B.
    Launay, J.
    Valentin, A.
    Reynes, O.
    Fabre, P-L.
    Nepveu, F.
    IRBM, 2008, 29 (2-3) : 141 - 148
  • [9] A novel aptasensor platform for the detection of carcinoembryonic antigen using quartz crystal microbalance
    Erkal-Aytemur, Asli
    Mulazimog, Ibrahim Ender
    Ustundag, Zafer
    Caglayan, Mustafa Oguzhan
    TALANTA, 2024, 277
  • [10] Blood Coagulation Testing Smartphone Platform Using Quartz Crystal Microbalance Dissipation Method
    Yao, Jia
    Feng, Bin
    Zhang, Zhiqi
    Li, Chuanyu
    Zhang, Wei
    Guo, Zhen
    Zhao, Heming
    Zhou, Lianqun
    SENSORS, 2018, 18 (09)