No difference between computer-assisted and conventional total knee arthroplasty: five-year results of a prospective randomised study

被引:45
作者
Luetzner, Joerg [1 ]
Dexel, Julian [1 ]
Kirschner, Stephan [1 ]
机构
[1] Tech Univ Dresden, Dept Orthopaed Surg, Univ Hosp Carl Gustav Carus, Fac Med, D-01307 Dresden, Germany
关键词
Total knee arthroplasty; Total knee replacement; Results; Navigation; NAVIGATION MEASUREMENTS; CLINICAL BENEFIT; ALIGNMENT; REPLACEMENT; COMPONENT; RISK; TKA;
D O I
10.1007/s00167-013-2608-7
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
The use of computer-assisted surgery (CAS) in total knee arthroplasty (TKA) results in better limb and implant alignment compared to conventional TKA; however, it is unclear whether this translates to better mid- to long-term clinical outcome. This prospective randomised study comparing CAS and conventional TKA reports the functional and patient perceived outcomes at a follow-up of 5 years. The hypothesis was that there would be a difference in functional outcome or quality of life after mid-term follow-up. Sixty-seven patients were available for physical and radiological examination at 5 years. The Knee Society Score (KSS) was used to describe functional outcome and the Euroquol questionnaire for quality of life. The mean total KSS for the CAS group improved from 91.1 (SD 22.3) points preoperatively to 157.4 (SD 21.9) and 150.2 (SD 30.4) points at 2 and 5 years, respectively. In the conventional group, the mean total KSS was 99.6 (SD 18.6) points preoperatively and 151.1 (SD 26.0) and 149.0 (SD 28.0) points at 2 and 5 years, respectively. The mean quality of life score improved from 48.2 (SD 16.5) points preoperatively to 67.4 (SD 16.3) and 66.8 (SD 22.2) points at 2 and 5 years in the CAS group, and from 52.2 (SD 17.1) points preoperatively to 65.6 (SD 14.6) and 61.7 (SD 19.3) points at 2 and 5 years, respectively, in the conventional TKA group. These differences were not statistically significant. There were radiolucent lines up to 2 mm in 11 knees (four CAS, seven conventional), but there were no changes in implant position. There were no significant differences in functional or patient perceived outcome after mid-term follow-up in this study. I.
引用
收藏
页码:2241 / 2247
页数:7
相关论文
共 44 条
[1]   Pin track induced fractures around computer-assisted TKA [J].
Beldame, J. ;
Boisrenoult, P. ;
Beaufils, P. .
ORTHOPAEDICS & TRAUMATOLOGY-SURGERY & RESEARCH, 2010, 96 (03) :249-255
[2]   The Chitranjan Ranawat Award: Is Neutral Mechanical Alignment Normal for All Patients?: The Concept of Constitutional Varus [J].
Bellemans, Johan ;
Colyn, William ;
Vandenneucker, Hilde ;
Victor, Jan .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2012, 470 (01) :45-53
[3]   Demographic biases of scoring instruments for the results of total knee arthroplasty [J].
Brinker, MR ;
Lund, PJ ;
Barrack, RL .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1997, 79A (06) :858-865
[4]   Computer-assisted Total Knee Arthroplasty Is Currently of No Proven Clinical Benefit: A Systematic Review [J].
Burnett, R. Stephen J. ;
Barrack, Robert L. .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2013, 471 (01) :264-276
[5]   Cost analysis for navigation in knee endoprosthetics [J].
Cerha, O. ;
Kirschner, S. ;
Guenther, K-P. ;
Luetzner, J. .
ORTHOPADE, 2009, 38 (12) :1235-1240
[6]   Does computer-assisted surgery improve postoperative leg alignment and implant positioning following total knee arthroplasty? A meta-analysis of randomized controlled trials? [J].
Cheng, Tao ;
Zhao, Song ;
Peng, Xiaochun ;
Zhang, Xianlong .
KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2012, 20 (07) :1307-1322
[7]   Imageless Navigation System Does Not Improve Component Rotational Alignment in Total Knee Arthroplasty [J].
Cheng, Tao ;
Zhang, Guoyou ;
Zhang, Xianlong .
JOURNAL OF SURGICAL RESEARCH, 2011, 171 (02) :590-600
[8]   Plain Radiograph Fails to Reflect the Alignment and Advantages of Navigation in Total Knee Arthroplasty [J].
Choi, Won Chul ;
Lee, Sahnghoon ;
An, Joon Hwan ;
Kim, Dongwook ;
Seong, Sang Cheol ;
Lee, Myung Chul .
JOURNAL OF ARTHROPLASTY, 2011, 26 (05) :756-764
[9]  
EuroQol Group, EQ 5D 3L US GUID
[10]  
EWALD FC, 1989, CLIN ORTHOP RELAT R, P9