Nuclear reaction measurements on tissue-equivalent materials and GEANT4 Monte Carlo simulations for hadrontherapy

被引:10
作者
De Napoli, M. [1 ]
Romano, F. [2 ]
D'Urso, D. [2 ]
Licciardello, T. [2 ]
Agodi, C. [2 ]
Candiano, G. [2 ]
Cappuzzello, F. [2 ,3 ]
Cirrone, G. A. P. [2 ]
Cuttone, G. [2 ]
Musumarra, A. [2 ,3 ]
Pandola, L. [2 ,4 ]
Scuderi, V. [2 ,5 ]
机构
[1] INFN, Sez Catania, I-95123 Catania, Italy
[2] INFN, Lab Nazl Sud, I-95123 Catania, Italy
[3] Univ Catania, Dipartimento Fis & Astron, I-95123 Catania, Italy
[4] INFN, Lab Nazl Gran Sasso, I-67100 Assergi, AQ, Italy
[5] ELI Beamlines Project, Inst Phys ASCR, Dept Expt Program ELI Beamlines, Prague, Czech Republic
关键词
Monte Carlo simulations; low and intermediate energy heavy-ion reactions; projectile and target fragmentation; dosimetry/exposure assessment; treatment strategy; Monte Carlo methods; simulation; FRAGMENTATION; MODELS; FLUKA; BEAM;
D O I
10.1088/0031-9155/59/24/7643
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
When a carbon beam interacts with human tissues, many secondary fragments are produced into the tumor region and the surrounding healthy tissues. Therefore, in hadrontherapy precise dose calculations require Monte Carlo tools equipped with complex nuclear reaction models. To get realistic predictions, however, simulation codes must be validated against experimental results; the wider the dataset is, the more the models are finely tuned. Since no fragmentation data for tissue-equivalent materials at Fermi energies are available in literature, we measured secondary fragments produced by the interaction of a 55.6 MeV u(-1) C-12 beam with thick muscle and cortical bone targets. Three reaction models used by the GEANT4 Monte Carlo code, the Binary Light Ions Cascade, the Quantum Molecular Dynamic and the Liege Intranuclear Cascade, have been benchmarked against the collected data. In this work we present the experimental results and we discuss the predictive power of the above mentioned models.
引用
收藏
页码:7643 / 7652
页数:10
相关论文
共 33 条
[1]   GEANT4-a simulation toolkit [J].
Agostinelli, S ;
Allison, J ;
Amako, K ;
Apostolakis, J ;
Araujo, H ;
Arce, P ;
Asai, M ;
Axen, D ;
Banerjee, S ;
Barrand, G ;
Behner, F ;
Bellagamba, L ;
Boudreau, J ;
Broglia, L ;
Brunengo, A ;
Burkhardt, H ;
Chauvie, S ;
Chuma, J ;
Chytracek, R ;
Cooperman, G ;
Cosmo, G ;
Degtyarenko, P ;
Dell'Acqua, A ;
Depaola, G ;
Dietrich, D ;
Enami, R ;
Feliciello, A ;
Ferguson, C ;
Fesefeldt, H ;
Folger, G ;
Foppiano, F ;
Forti, A ;
Garelli, S ;
Giani, S ;
Giannitrapani, R ;
Gibin, D ;
Cadenas, JJG ;
González, I ;
Abril, GG ;
Greeniaus, G ;
Greiner, W ;
Grichine, V ;
Grossheim, A ;
Guatelli, S ;
Gumplinger, P ;
Hamatsu, R ;
Hashimoto, K ;
Hasui, H ;
Heikkinen, A ;
Howard, A .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2003, 506 (03) :250-303
[2]   Geant4 developments and applications [J].
Allison, J ;
Amako, K ;
Apostolakis, J ;
Araujo, H ;
Dubois, PA ;
Asai, M ;
Barrand, G ;
Capra, R ;
Chauvie, S ;
Chytracek, R ;
Cirrone, GAP ;
Cooperman, G ;
Cosmo, G ;
Cuttone, G ;
Daquino, GG ;
Donszelmann, M ;
Dressel, M ;
Folger, G ;
Foppiano, F ;
Generowicz, J ;
Grichine, V ;
Guatelli, S ;
Gumplinger, P ;
Heikkinen, A ;
Hrivnacova, I ;
Howard, A ;
Incerti, S ;
Ivanchenko, V ;
Johnson, T ;
Jones, F ;
Koi, T ;
Kokoulin, R ;
Kossov, M ;
Kurashige, H ;
Lara, V ;
Larsson, S ;
Lei, F ;
Link, O ;
Longo, F ;
Maire, M ;
Mantero, A ;
Mascialino, B ;
McLaren, I ;
Lorenzo, PM ;
Minamimoto, K ;
Murakami, K ;
Nieminen, P ;
Pandola, L ;
Parlati, S ;
Peralta, L .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2006, 53 (01) :270-278
[3]  
Battistoni G, 2007, AIP CONF PROC, V896, P31, DOI 10.1063/1.2720455
[4]   Benchmarking nuclear models of FLUKA and GEANT4 for carbon ion therapy [J].
Bohlen, T. T. ;
Cerutti, F. ;
Dosanjh, M. ;
Ferrari, A. ;
Gudowska, I. ;
Mairani, A. ;
Quesada, J. M. .
PHYSICS IN MEDICINE AND BIOLOGY, 2010, 55 (19) :5833-5847
[5]   Intranuclear cascade model for a comprehensive description of spallation reaction data [J].
Boudard, A ;
Cugnon, J ;
Leray, S ;
Volant, C .
PHYSICAL REVIEW C, 2002, 66 (04) :28
[6]   Nuclear reaction measurements of 95 MeV/u 12C interactions on PMMA for hadrontherapy [J].
Braunn, B. ;
Labalme, M. ;
Ban, G. ;
Chevallier, M. ;
Colin, J. ;
Cussol, D. ;
Dauvergne, D. ;
Fontbonne, J. M. ;
Haas, F. ;
Guertin, A. ;
Lebhertz, D. ;
Le Foulher, F. ;
Pautard, C. ;
Ray, C. ;
Rousseau, M. ;
Salsac, M. D. ;
Stuttge, L. ;
Testa, E. ;
Testa, M. .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2011, 269 (22) :2676-2684
[7]   Carbon fragmentation measurements and validation of the GEANT4 nuclear reaction models for hadrontherapy [J].
De Napoli, M. ;
Agodi, C. ;
Battistoni, G. ;
Blancato, A. A. ;
Cirrone, G. A. P. ;
Cuttone, G. ;
Giacoppo, F. ;
Morone, M. C. ;
Nicolosi, D. ;
Pandola, L. ;
Patera, V. ;
Raciti, G. ;
Rapisarda, E. ;
Romano, F. ;
Sardina, D. ;
Sarti, A. ;
Sciubba, A. ;
Scuderi, V. ;
Sfienti, C. ;
Tropea, S. .
PHYSICS IN MEDICINE AND BIOLOGY, 2012, 57 (22) :7651-7671
[8]   SHIELD - universal Monte Carlo hadron transport code: scope and applications [J].
Dementyev, AV ;
Sobolevsky, NM .
RADIATION MEASUREMENTS, 1999, 30 (05) :553-557
[9]   Double-differential fragmentation cross-section measurements of 95 MeV/nucleon 12C beams on thin targets for hadron therapy [J].
Dudouet, J. ;
Juliani, D. ;
Labalme, M. ;
Cussol, D. ;
Angelique, J. C. ;
Braunn, B. ;
Colin, J. ;
Finck, Ch. ;
Fontbonne, J. M. ;
Guerin, H. ;
Henriquet, P. ;
Krimmer, J. ;
Rousseau, M. ;
Saint-Laurent, M. G. ;
Salvador, S. .
PHYSICAL REVIEW C, 2013, 88 (02)
[10]  
Ferrari A, 2005, CERN-2005-10, INFN/TC_05/11, SLAC-R-773