Field study method for indoor air of linear underground facilities

被引:0
|
作者
Lushin, Kirill [1 ]
Plyushchenko, Natalia [1 ]
Ananyev, Aleksey [2 ]
机构
[1] Moscow State Univ Civil Engn, Yaroslayskoye Sh 26, Moscow 129337, Russia
[2] Russian Acad Architecture & Construct Sci NIISF R, Moscow, Russia
关键词
D O I
10.1051/matecconf/20168604039
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The article describes the approach to the organization of field studies of air and thermal regime of underground structures on the basis of experiments carried out in the underground channels with sufficient maintenance.
引用
收藏
页数:5
相关论文
共 50 条
  • [1] Field study on indoor air quality of wood remodeled welfare facilities for physical and psychological benefits
    Cho, Hyun Mi
    Lee, Jongki
    Wi, Seunghwan
    Kim, Sumin
    JOURNAL OF CLEANER PRODUCTION, 2019, 233 : 197 - 208
  • [2] Carbon monoxide and volatile organic compounds as indicators of indoor air quality in underground parking facilities
    El Fadel, M
    Alameddine, I
    Kazopoulo, M
    Hamdan, M
    Nasrallah, R
    INDOOR AND BUILT ENVIRONMENT, 2001, 10 (02) : 70 - 82
  • [3] Effects of Legal Regulation on Indoor Air Quality in Facilities for Sensitive Populations – A Field Study in Seoul, Korea
    Jinho Yang
    Ji-Hoon Seo
    Na-Na Jeong
    Jong-Ryeul Sohn
    Environmental Management, 2019, 64 : 344 - 352
  • [4] Effects of Legal Regulation on Indoor Air Quality in Facilities for Sensitive Populations - A Field Study in Seoul, Korea
    Yang, Jinho
    Seo, Ji-Hoon
    Jeong, Na-Na
    Sohn, Jong-Ryeul
    ENVIRONMENTAL MANAGEMENT, 2019, 64 (03) : 344 - 352
  • [5] Survey on the indoor air of the underground space
    Qu, GL
    Yue, LJ
    Min, YQ
    Ma, GH
    Li, FR
    INDOOR AIR 2005: PROCEEDINGS OF THE 10TH INTERNATIONAL CONFERENCE ON INDOOR AIR QUALITY AND CLIMATE, VOLS 1-5, 2005, : 957 - 965
  • [6] A Study on Characteristics of Main Indoor Air Pollutants and Ventilation in Nursery Facilities
    Kim, Sang Cheol
    Kang, Byeong-Chang
    Lee, Sang-Uk
    Kim, Gi-Doo
    Seo, Won-Ho
    Kim, Jong-Heon
    JOURNAL OF KOREAN SOCIETY FOR ATMOSPHERIC ENVIRONMENT, 2014, 30 (03) : 245 - 250
  • [7] A survey of indoor air quality in public facilities
    Kim, YS
    Roh, YM
    Hong, SC
    Lee, CM
    Jun, HJ
    Kim, JC
    Cho, JH
    INDOOR AIR 2005: PROCEEDINGS OF THE 10TH INTERNATIONAL CONFERENCE ON INDOOR AIR QUALITY AND CLIMATE, VOLS 1-5, 2005, : 833 - 836
  • [8] MUTAGENICITY OF INDOOR AIR IN A RESIDENTIAL FIELD-STUDY
    LEWTAS, J
    GOTO, S
    WILLIAMS, K
    CHAPELL, J
    WILSON, N
    ENVIRONMENTAL MUTAGENESIS, 1987, 9 : 58 - 59
  • [9] Field study of an underground counterflow heat exchanger for ventilation air
    Nilsson, L
    Kangro, A
    SWEDISH JOURNAL OF AGRICULTURAL RESEARCH, 1998, 28 (04): : 207 - 213
  • [10] Indoor air quality assessment in an underground parking facility
    El Fadel, M
    Alameddine, I
    Kazopoulo, M
    Hamdan, M
    Nasrallah, R
    INDOOR AND BUILT ENVIRONMENT, 2001, 10 (3-4) : 179 - 184