Simultaneous analysis of 28 urinary VOC metabolites using ultra high performance liquid chromatography coupled with electrospray ionization tandem mass spectrometry (UPLC-ESI/MSMS)

被引:252
作者
Alwis, K. Udeni [1 ]
Blount, Benjamin C. [1 ]
Britt, April S. [1 ]
Patel, Dhrusti [1 ]
Ashley, David L. [1 ]
机构
[1] Ctr Dis Control & Prevent, Natl Ctr Environm Hlth, Div Sci Lab, Atlanta, GA 30341 USA
关键词
VOC metabolites; Urinary biomarkers; Tobacco-related; UPLC-ESI/MSMS; Endogenous; Correlation; VOLATILE ORGANIC-COMPOUNDS; S-PHENYLMERCAPTURIC ACID; MAJOR MERCAPTURIC ACIDS; BENZENE EXPOSURE; STYRENE; BLOOD; RAT; QUANTIFICATION; 1,3-BUTADIENE; POPULATION;
D O I
10.1016/j.aca.2012.04.009
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Volatile organic compounds (VOCs) are ubiquitous in the environment, originating from many different natural and anthropogenic sources, including tobacco smoke. Long-term exposure to certain VOCs may increase the risk for cancer, birth defects, and neurocognitive impairment. Therefore. VOC exposure is an area of significant public health concern. Urinary VOC metabolites are useful biomarkers for assessing VOC exposure because of non-invasiveness of sampling and longer physiological half-lives of urinary metabolites compared with VOCs in blood and breath. We developed a method using reversed-phase ultra high performance liquid chromatography (UPLC) coupled with electrospray ionization tandem mass spectrometry (ESI/MSMS) to simultaneously quantify 28 urinary VOC metabolites as biomarkers of exposure. We describe a method that monitors metabolites of acrolein, acrylamide, acrylonitrile, benzene, 1-bromopropane, 1,3-butadiene, carbon-disulfide, crotonaldehyde, cyanide, N,N-dimethylformamide, ethylbenzene, ethylene oxide, propylene oxide, styrene, tetrachloroethylene, toluene, trichloroethylene, vinyl chloride and xylene. The method is accurate (mean accuracy for spiked matrix ranged from 84 to104%), sensitive (limit of detection ranged from 0.5 to 20 ng mL(-1)) and precise (the relative standard deviations ranged from 2.5 to 11%). We applied this method to urine samples collected from 1203 non-smokers and 347 smokers and demonstrated that smokers have significantly elevated levels of tobacco-related biomarkers compared to non-smokers. We found significant (p < 0.0001) correlations between serum cotinine and most of the tobacco-related biomarkers measured. These findings confirm that this method can effectively quantify urinary VOC metabolites in a population exposed to volatile organics. Published by Elsevier B.V.
引用
收藏
页码:152 / 160
页数:9
相关论文
共 46 条
[1]  
ACGIH - American Conference of Government Industrial Hygienists, 2007, ACGIH AM C GOV IND H
[2]  
Albertini Richard J, 2003, Res Rep Health Eff Inst, P1
[3]   NEUROPHYSIOLOGICAL AND PSYCHOPHYSICAL MEASUREMENTS REVEAL EFFECTS OF ACUTE LOW-LEVEL ORGANIC-SOLVENT EXPOSURE IN HUMANS [J].
ALTMANN, L ;
BOTTGER, A ;
WIEGAND, H .
INTERNATIONAL ARCHIVES OF OCCUPATIONAL AND ENVIRONMENTAL HEALTH, 1990, 62 (07) :493-499
[4]  
[Anonymous], CHILDR SEC SMOK EXP
[5]  
[Anonymous], 2010, MORBIDITY MORTALITY
[6]   Measurement of volatile organic compounds in human blood [J].
Ashley, DL ;
Bonin, MA ;
Cardinali, FL ;
McCraw, JM ;
Wooten, JV .
ENVIRONMENTAL HEALTH PERSPECTIVES, 1996, 104 :871-877
[7]  
Bernert JT, 1997, CLIN CHEM, V43, P2281
[8]   Quantification of 31 volatile organic compounds in whole blood using solid-phase microextraction and gas chromatography-mass spectrometry [J].
Blount, BC ;
Kobelski, RJ ;
McElprang, DO ;
Ashley, DL ;
Morrow, JC ;
Chambers, DM ;
Cardinali, FL .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2006, 832 (02) :292-301
[9]   Determination of the major mercapturic acids of acrylamide and glycidamide in human urine by LC-ESI-MS/MS [J].
Boettcher, MI ;
Angerer, J .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2005, 824 (1-2) :283-294
[10]   Drinking water and cancer [J].
Cantor, KP .
CANCER CAUSES & CONTROL, 1997, 8 (03) :292-308