Pulmonary vein morphology by free-breathing whole heart magnetic resonance imaging at 3 tesla versus breathhold multi-detector computed tomography

被引:3
作者
Fodi, Eszter [1 ]
McAreavey, Dorothea [2 ]
Abd-Elmoniem, Khaled Z. [1 ]
Ohayon, Jacques [1 ]
Saba, Magdi [3 ]
Elagha, Abdalla [1 ]
Pettigrew, Roderic I. [1 ]
Gharib, Ahmed M. [1 ]
机构
[1] NIDDK, NIH, Bethesda, MD USA
[2] NIH, Ctr Clin, Bethesda, MD 20892 USA
[3] Univ London, Dept Cardiovasc Med, London WC1E 7HU, England
关键词
magnetic resonance imaging; multidetector computed tomography; atrium; pulmonary vein; vessels; RADIOFREQUENCY CATHETER ABLATION; CORONARY MR-ANGIOGRAPHY; CROSS-SECTIONAL AREA; ATRIAL-FIBRILLATION; CONTRAST; ACCURACY; ANATOMY; IMPACT; RESPIRATION; DIAMETER;
D O I
10.1002/jmri.23865
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To compare pulmonary vein and left atrial anatomy using three-dimensional free-breathing whole-heart magnetic resonance imaging (MR) at 3 Tesla (T) and multi-detector computed tomography (MDCT). Materials and Methods: Thirty-three subjects (19 male, age 49 +/- 12 years) underwent free-breathing 3T MR and contrast-enhanced MDCT during inspiratory breath hold. Pulmonary vein parameters (ostial areas, diameters, angles) were measured. Results: All pulmonary veins and anomalies were identified by 3T MR and by MDCT. The right-sided pulmonary veins were directed more posteriorly, the right superior pulmonary vein more inferiorly, and the right inferior pulmonary vein more superiorly by 3T MR when compared with MDCT. The cross-sectional area, perimeters and minimum diameters of right-sided pulmonary vein ostia were significantly larger by MR, as were the maximum diameters of right and left inferior pulmonary veins. There were no significant differences between techniques in distance to first pulmonary vein branch. Conclusion: Pulmonary vein measurements demonstrated significant differences in angulations and dimensions when 3T MR is compared with MDCT. These differences likely represent hemodynamic and respiratory variation during free-breathing with MR versus breath-holding with MDCT. MR imaging at 3T during free-breathing offers an alternate method to define pulmonary vein and left atrial anatomy without exposure to radiation. J. Magn. Reson. Imaging 2013;37:846852. (c) 2012 Wiley Periodicals, Inc.
引用
收藏
页码:846 / 852
页数:7
相关论文
共 33 条
[1]   MR evaluation of pulmonary vein diameter reduction after radiofrequency catheter ablation of atrial fibrillation [J].
Anselme, Frederic ;
Gahide, Gerald ;
Savoure, Arnaud ;
Gerbaud, Edouard ;
Mabru, Mikael ;
Cribier, Alain ;
Dacher, Jean-Nicolas .
EUROPEAN RADIOLOGY, 2006, 16 (11) :2505-2511
[2]   Respiratory compensation improves the accuracy of electroanatomic mapping of the left atrium and pulmonary veins during atrial fibrillation ablation [J].
Beinart, Roy ;
Kabra, Rajesh ;
Heist, Kevin E. ;
Blendea, Dan ;
Barrett, Conor D. ;
Danik, Stephan B. ;
Collins, Ryan ;
Ruskin, Jeremy N. ;
Mansour, Moussa .
JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY, 2011, 32 (02) :105-110
[3]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[4]   ACC/AHA/ESC 2006 Guidelines for the Management of Patients With Atrial Fibrillation A Report of the American College of Cardiology/American Heart Association Task Force on Practice Guidelines and the European Society of Cardiology Committee for Practice Guidelines (Writing Committee to Revise the 2001 Guidelines for the Management of Patients With Atrial Fibrillation) Developed in Collaboration With the European Heart Rhythm Association and the Heart Rhythm Society [J].
Fuster, Valentin ;
Ryden, Lars E. ;
Cannom, David S. ;
Crijns, Harry J. ;
Curtis, Anne B. ;
Ellenbogen, Kenneth A. ;
Halperin, Jonathan L. ;
Le Heuzey, Jean-Yves ;
Kay, G. Neal ;
Lowe, James E. ;
Olsson, S. Bertil ;
Prystowsky, Eric N. ;
Tamargo, Juan Luis ;
Wann, Samuel .
CIRCULATION, 2006, 114 (07) :E257-E354
[5]   Accuracy of 16-row multidetector computed tomography for the assessment of coronary artery stenosis [J].
Garcia, Mario J. ;
Lessick, Jonathan ;
Hoffmann, Martin H. K. .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2006, 296 (04) :403-411
[6]   Coronary artery anomalies and variants: Technical feasibility of assessment with coronary MR angiography at 3T [J].
Gharib, Ahmed M. ;
Ho, Vincent B. ;
Rosing, Douglas R. ;
Herzka, Daniel A. ;
Stuber, Matthias ;
Arai, Andrew E. ;
Pettigrew, Roderic I. .
RADIOLOGY, 2008, 247 (01) :220-227
[7]   Optimization of coronary whole-heart MRA free-breathing technique at 3 Tesla [J].
Gharib, Ahmed M. ;
Abd-Elmoniem, Khaled Z. ;
Herzka, Daniel A. ;
Ho, Vincent B. ;
Locklin, Julie ;
Tzatha, Efstathia ;
Stuber, Matthias ;
Pettigrew, Roderic I. .
MAGNETIC RESONANCE IMAGING, 2011, 29 (08) :1125-1130
[8]   Cardiac Magnetic Resonance at High Field: Promises and Problems [J].
Gharib, Ahmed M. ;
Elagha, Abdalla ;
Pettigrew, Roderic I. .
CURRENT PROBLEMS IN DIAGNOSTIC RADIOLOGY, 2008, 37 (02) :49-56
[9]  
Hainsworth R., 2004, ANAESTH INTENSIVE CA, V5, P184
[10]   A method for the determination of proximal pulmonary vein size using contrast-enhanced magnetic resonance angiography [J].
Hauser, TH ;
Yeon, SB ;
McClennen, S ;
Katsimaglis, G ;
Kissinger, KV ;
Josephson, ME ;
Rofsky, NM ;
Manning, WJ .
JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2004, 6 (04) :927-936