Automatic three-dimensional inspection of patient setup in radiation therapy using portal images, simulator images, and computed tomography data

被引:116
作者
Gilhuijs, KGA
vandeVen, PJH
vanHerk, M
机构
[1] Netherlands Cancer Institute, 1066 CX Amsterdam
[2] Radiotherapy Department, Netherlands Cancer Institute, 1066 CX Amsterdam
关键词
portal imaging; 3D patient setup; digitally reconstructed radiographs (DRR); out-of-plane rotations;
D O I
10.1118/1.597801
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
In external beam radiotherapy, conventional analysis of portal images in two dimensions (2D) is limited to verification of in-plane rotations and translations of the patient. We developed and clinically tested a new method for automatic quantification of the patient setup in three dimensions (3D) using one set of computed tomography (CT) data and two transmission images. These transmission images can be either a pair of simulator images or a pair of portal images. Our procedure adjusts the position and orientation of the CT data in order to maximize the distance through bone in the CT data along lines between the focus of the irradiation unit and bony structures in the transmission images. For this purpose, bony features are either automatically detected or manually delineated in the transmission images. The performance of the method was quantified by aligning randomly displaced CT data with transmission images simulated from digitally reconstructed rao diographs. In addition, the clinical performance was assessed in a limited number of images of prostate cancer and parotid gland tumor treatments. The complete procedure takes less than 2 min on a 90-MHz Pentium PC. The alignment time is 50 s for portal images and 80 a for simulator images. The accuracy is about 1 mm and 1 degrees. Application to clinical cases demonstrated that the procedure provides essential information for the correction of setup errors in case of large rotations (typically larger than 2 degrees) in the setup. The 3D procedure was found to be robust for imperfections in the delineation of bony structures in the transmission images. Visual verification of the results remains, however, necessary. It can be concluded that our strategy for automatic analysis of patient setup in 3D is accurate and robust. The procedure is relatively fast and reduces the human workload compared with existing techniques for the quantification of patient setup in 3D. In addition, the procedure improves the accuracy of treatment verification in 2D in some cases where rotational deviations in the setup occur. (C) 1996 American Association of Physicists in Medicine.
引用
收藏
页码:389 / 399
页数:11
相关论文
共 41 条
  • [31] A PATIENT-TO-COMPUTED-TOMOGRAPHY IMAGE REGISTRATION METHOD BASED ON DIGITALLY RECONSTRUCTED RADIOGRAPHS
    LEMIEUX, L
    JAGOE, R
    FISH, DR
    KITCHEN, ND
    THOMAS, DGT
    [J]. MEDICAL PHYSICS, 1994, 21 (11) : 1749 - 1760
  • [32] A SIMPLEX-METHOD FOR FUNCTION MINIMIZATION
    NELDER, JA
    MEAD, R
    [J]. COMPUTER JOURNAL, 1965, 7 (04) : 308 - 313
  • [33] SCHEWE JE, 1995, MED PHYS, V22, P939
  • [34] COMPUTATION OF DIGITALLY RECONSTRUCTED RADIOGRAPHS FOR USE IN RADIOTHERAPY TREATMENT DESIGN
    SHEROUSE, GW
    NOVINS, K
    CHANEY, EL
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1990, 18 (03): : 651 - 658
  • [35] SOLUTION TO TREATMENT PLANNING PROBLEMS USING COORDINATE TRANSFORMATIONS
    SIDDON, RL
    [J]. MEDICAL PHYSICS, 1981, 8 (06) : 766 - 774
  • [36] 3-DIMENSIONAL MOTION ANALYSIS OF AN IMPROVED HEAD IMMOBILIZATION SYSTEM FOR SIMULATION, CT, MRI, AND PET IMAGING
    THORNTON, AF
    TENHAKEN, RK
    GERHARDSSON, A
    CORRELL, M
    [J]. RADIOTHERAPY AND ONCOLOGY, 1991, 20 (04) : 224 - 228
  • [37] A COMPREHENSIVE SYSTEM FOR THE ANALYSIS OF PORTAL IMAGES
    VANHERK, M
    BEL, A
    GILHUIJS, KGA
    VIJLBRIEF, RE
    [J]. RADIOTHERAPY AND ONCOLOGY, 1993, 29 (02) : 221 - 229
  • [38] A MATRIX IONIZATION-CHAMBER IMAGING DEVICE FOR ONLINE PATIENT SETUP VERIFICATION DURING RADIOTHERAPY
    VANHERK, M
    MEERTENS, H
    [J]. RADIOTHERAPY AND ONCOLOGY, 1988, 11 (04) : 369 - 378
  • [39] Quantification of organ motion during conformal radiotherapy of the prostate by three dimensional image registration
    vanHerk, M
    Bruce, A
    Kroes, APG
    Shouman, T
    Touw, A
    Lebesque, JV
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1995, 33 (05): : 1311 - 1320
  • [40] PORTAL DOSE IMAGES .1. QUANTITATIVE TREATMENT PLAN VERIFICATION
    WONG, JW
    SLESSINGER, ED
    HERMES, RE
    OFFUTT, CJ
    ROY, T
    VANNIER, MW
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1990, 18 (06): : 1455 - 1463