A compton-suppressed phoswich detector for gamma spectroscopy

被引:11
|
作者
Farsoni, A. T. [1 ]
Alemayehu, B. [1 ]
Alhawsawi, A. [1 ]
Becker, E. M. [1 ]
机构
[1] Oregon State Univ, Corvallis, OR 97330 USA
关键词
Phoswich detectors; Scintillators; Compton suppression; Gamma spectroscopy; Digital pulse-shape discrimination; SAMPLES; CS-137;
D O I
10.1007/s10967-012-2009-2
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A phoswich detector with two scintillation layers has been designed and assembled at Oregon State University. This detector is able to identify and reject Compton events and ultimately reduce the Compton continuum in gamma energy spectra. In this detector, CsI(Tl) crystal is used to primarily detect photoelectric events. The CsI(Tl) crystal is partially surrounded by a BGO crystal layer to capture and identify Compton-scattered photons. Both crystals are optically coupled to a single photomultiplier tube. A real-time, FPGA-based digital pulse shape analysis was developed to discriminate and reject Compton-induced pulses from the CsI(Tl) crystal. All the digital pulse processing functions including pulse shape discrimination analysis, pile-up rejection and energy measurement were implemented in an on-board FPGA device. In this paper, the results of recent measurements using radioactive lab sources will be presented and discussed.
引用
收藏
页码:63 / 68
页数:6
相关论文
共 50 条
  • [1] A compton-suppressed phoswich detector for gamma spectroscopy
    A. T. Farsoni
    B. Alemayehu
    A. Alhawsawi
    E. M. Becker
    Journal of Radioanalytical and Nuclear Chemistry, 2013, 296 : 63 - 68
  • [2] An entrance window surrounded phoswich design for efficient large-angle Compton-suppressed and low-background GAGG: Ce detector
    Wang, H. D.
    Lu, Jing-Bin
    Li, R. P.
    Gao, T. J.
    Li, Chengqian
    Qu, Huan
    Zhu, Li-Hua
    Li, Cong-Bo
    Zheng, Yun
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2023, 1055
  • [3] On the design and installation of a Compton-suppressed HPGe spectrometer at the Budapest neutron-induced prompt gamma spectroscopy (NIPS) facility
    Szentmiklosi, Laszlo
    Kis, Zoltan
    Belgya, Tamas
    Berlizov, Andrey N.
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2013, 298 (03) : 1605 - 1611
  • [4] Application of wavelet transform in anti-Compton phoswich detector for gamma spectrum
    Liu, Changqi
    Tao, Kai
    Peng, Jinqiu
    E, Dejun
    Li, Weimin
    Huang, Liming
    Bai, Xiaohou
    Ma, Zhanwen
    NUCLEAR ENGINEERING AND TECHNOLOGY, 2024, 56 (10) : 4390 - 4396
  • [5] A Phoswich Detector With Compton Suppression Capability for Radioxenon Measurements
    Farsoni, Abi T.
    Alemayehu, Bemnet
    Alhawsawi, Abdulsalam
    Becker, Eric M.
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2013, 60 (01) : 456 - 464
  • [6] A Compton suppressed detector multiplicity trigger based digital DAQ for gamma-ray spectroscopy
    Das, S.
    Samanta, S.
    Banik, R.
    Bhattacharjee, R.
    Basu, K.
    Raut, R.
    Ghugre, S. S.
    Sinha, A. K.
    Bhattacharya, S.
    Imran, S.
    Mukherjee, G.
    Bhattacharyya, S.
    Goswami, A.
    Palit, R.
    Tan, H.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2018, 893 : 138 - 145
  • [7] Measured and simulated performance of Compton-suppressed TIGRESS HPGe clover detectors
    Schumaker, M. A.
    Hackman, G.
    Pearson, C. J.
    Svensson, C. E.
    Andreoiu, C.
    Andreyev, A.
    Austin, R. A. E.
    Ball, G. C.
    Bandyopadhyay, D.
    Boston, A. J.
    Chakrawarthy, R. S.
    Churchman, R.
    Drake, T. E.
    Finlay, P.
    Garrett, P. E.
    Grinyer, G. F.
    Hyland, B.
    Jones, B.
    Maharaj, R.
    Morton, A. C.
    Phillips, A. A.
    Sarazin, F.
    Scraggs, H. C.
    Smith, M. B.
    Valiente-Dobon, J. J.
    Waddington, J. C.
    Watters, L. M.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2007, 570 (03): : 437 - 445
  • [8] Operation of a high-purity germanium crystal in liquid argon as a Compton-suppressed radiation spectrometer
    Orrell, John L.
    Aalseth, Craig E.
    Amsbaugh, John F.
    Doe, Peter J.
    Hossbach, Todd W.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2007, 579 (01): : 91 - 93
  • [9] Monte Carlo characterisation of a Compton suppressed broad-energy HPGe detector
    R. Britton
    J. L. Burnett
    A. V. Davies
    P. H. Regan
    Journal of Radioanalytical and Nuclear Chemistry, 2014, 300 : 1253 - 1259
  • [10] Monte Carlo characterisation of a Compton suppressed broad-energy HPGe detector
    Britton, R.
    Burnett, J. L.
    Davies, A. V.
    Regan, P. H.
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2014, 300 (03) : 1253 - 1259