Electrospun nanofibers as a new solid phase microextraction coating for determination of volatile organic impurities in biological products

被引:3
|
作者
Zali, Sara [1 ,2 ]
Es-haghi, Ali [1 ]
Shamsipur, Mojtaba [2 ]
Jalali, Fahimeh [2 ]
机构
[1] Agr Res Educ & Extens Org AREEO, Dept Phys Chem, Razi Vaccine & Serum Res Inst, POB 31975-148, Karaj, Iran
[2] Razi Univ, Dept Chem, Kermanshah, Iran
来源
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES | 2020年 / 1153卷
关键词
Residual solvent; Solid-phase microextraction; Electrospun nanofiber; Polystyrene; Anti venom; Foot-and-mouth disease vaccine; CHROMATOGRAPHY-MASS SPECTROMETRY; HS-SPME; FIBERS; TECHNOLOGY;
D O I
10.1016/j.jchromb.2020.122279
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
In this study, preparation of a solid-phase microextraction fiber of polydimethylsiloxane (PDMS) polymer in its blends with polystyrene (PS) via electrospinning process, on a stainless steel wire has been reported. The electrospining enhancement of PDMS solutions in the presence of PS is found due to the increase in the viscosity of the mixed solutions. Characteristics of the fibers were inspected by energy dispersive X-ray spectroscopy, scanning electron microscopy and field emission scanning electron microscopy. The applicability of the coating was assessed for headspace solid phase microextraction (SPME) of some residual solvents (Diethyl Ether, Toluene and Chloroform) from biological products (Anti venin and Foot-and-mouth disease vaccine) followed by gas chromatography-mass spectrometry. The effects of extraction time and temperature, desorption time and temperature, agitation rate and ionic strength on the extraction efficiency were investigated. Under optimized conditions, limits of detection in the range of 2-10 mu g L-1 and limits of quantification in the range of 10-50 mu g L-1 were obtained. The method showed linearity in a wide range with a correlation coefficient greater than 0.99. In addition, the obtained inter-day and infra-day precisions were in the range of 1.57-8.28% and 4.87-11.72%, respectively. The thermal stability of the fiber was also investigated and it was found to be durable at 230 degrees C for 450 min. Furthermore, the proposed method was successfully applied for quantification of chloroform in Foot-and-mouth disease vaccine and diethyl ether and toluene in Anti-venin with recoveries in the range of 78.84-123.01%.
引用
收藏
页数:9
相关论文
共 50 条
  • [21] Headspace solid phase microextraction (HSSPME) for the determination of volatile and semivolatile pollutants in soils
    Llompart, M
    Li, K
    Fingas, M
    TALANTA, 1999, 48 (02) : 451 - 459
  • [22] Fe3O4/polyethylene glycol nanocomposite as a solid-phase microextraction fiber coating for the determination of some volatile organic compounds in water
    Farjaminezhad, Manoochehr
    Tehrani, Mohammad Saber
    Azar, Parviz Aberoomand
    Bohlooli, Shahab
    Hussain, Syed Waqif
    JOURNAL OF SEPARATION SCIENCE, 2017, 40 (03) : 717 - 724
  • [23] Triazine-based covalent organic polymer: A promising coating for solid-phase microextraction
    Wang, Zhuo
    Zhang, Ying
    Chang, Guifen
    Li, Jinqiu
    Yang, Xiumin
    Zhang, Shuaihua
    Zang, Xiaohuan
    Wang, Chun
    Wang, Zhi
    JOURNAL OF SEPARATION SCIENCE, 2021, 44 (19) : 3608 - 3617
  • [24] DETERMINATION OF VOLATILE CHLORINATED HYDROCARBONS IN AIR AND WATER WITH SOLID-PHASE MICROEXTRACTION
    CHAI, M
    ARTHUR, CL
    PAWLISZYN, J
    BELARDI, RP
    PRATT, KF
    ANALYST, 1993, 118 (12) : 1501 - 1505
  • [25] Evaluation of matrix effects in the analysis of volatile organic compounds in whole blood with solid-phase microextraction
    Alonso, Monica
    Castellanos, Mar
    Sanchez, Juan M.
    JOURNAL OF SEPARATION SCIENCE, 2013, 36 (23) : 3776 - 3782
  • [26] Fabrication of novel nanoporous array anodic alumina solid-phase microextraction fiber coating and its potential application for headspace sampling of biological volatile organic compounds
    Zhang, Zhuomin
    Wang, Qingtang
    Li, Gongke
    ANALYTICA CHIMICA ACTA, 2012, 727 : 13 - 19
  • [27] Headspace Solid-Phase Microextraction Coupled with Gas Chromatography–Mass Spectrometry for the Determination of Volatile Organic Compounds in Urine
    Małgorzata Natalia Drabińska
    Urszula Starowicz
    Journal of Analytical Chemistry, 2020, 75 : 792 - 801
  • [28] Use of polymeric fullerene as a new coating for solid-phase microextraction
    Xiao, CH
    Liu, ZL
    Wang, ZY
    Wu, CY
    Han, HM
    CHROMATOGRAPHIA, 2000, 52 (11-12) : 803 - 809
  • [29] Carbon nanocones/disks as new coating for solid-phase microextraction
    Manuel Jimenez-Soto, Juan
    Cardenas, Soledad
    Valcarcel, Miguel
    JOURNAL OF CHROMATOGRAPHY A, 2010, 1217 (20) : 3341 - 3347
  • [30] Covalent organic nanospheres as a fiber coating for solid-phase microextraction of genotoxic impurities followed by analysis using GC-MS
    Zhao, Yanfang
    Li, Jingkun
    Xie, Hanyi
    Li, Huijuan
    Chen, Xiangfeng
    JOURNAL OF PHARMACEUTICAL ANALYSIS, 2022, 12 (04) : 583 - 589