Intercomparisons of experimental convective heat transfer coefficients and mass transfer coefficients of urban surfaces

被引:50
|
作者
Hagishima, A [1 ]
Tanimoto, J [1 ]
Narita, K [1 ]
机构
[1] Kyushu Univ, Interdisciplinary Grad Sch Engn Sci, Kasuga, Fukuoka 8168580, Japan
基金
日本科学技术振兴机构;
关键词
Convective heat transfer coefficient; Intercomparison; Mass transfer coefficient; Urban canopy model; Wind-tunnel experiment;
D O I
10.1007/s10546-005-2078-7
中图分类号
P4 [大气科学(气象学)];
学科分类号
0706 ; 070601 ;
摘要
The convective heat transfer coefficient (CHTC) of an urban canopy is a crucial parameter for estimating the turbulent heat flux in an urban area. We compared recent experimental research on the CHTC and the mass transfer coefficient (MTC) of urban surfaces in the field and in wind tunnels. Our findings are summarised as follows. (1)In full-scale measurements on horizontal building roofs, the CHTC is sensitive to the height of the reference wind speed for heights below 1.5 m but is relatively independent of roof size. (2)In full-scale measurements of vertical building walls, the dependence of the CHTC on wind speed is significantly influenced by the choice of the measurement position and wall size. The CHTC of the edge of the building wall is much higher than that near the centre. (3) In spite of differences of the measurement methods, wind-tunnel experiments of the MTC give similar relations between the ratio of street width to canopy height in the urban canopy. Moreover, this relationship is consistent with known properties of the flow regime of an urban canopy. (4) Full-scale measurements on roofs result in a non-dimensional CHTC several tens of times greater than that in scale-model experiments with the same Reynolds number. Although there is some agreement in the measured values, our overall understanding of the CHTC remains too low for accurate modelling of urban climate.
引用
收藏
页码:551 / 576
页数:26
相关论文
共 50 条