Reduction of signal suppression effects in ESI-MS using a nanosplitting device

被引:145
作者
Gangl, ET
Annan, M
Spooner, N
Vouros, P [1 ]
机构
[1] Northeastern Univ, Barnett Inst, Boston, MA 02115 USA
[2] Northeastern Univ, Dept Chem, Boston, MA 02115 USA
[3] GlaxoSmithKline Pharmaceut, King Of Prussia, PA 19406 USA
关键词
D O I
10.1021/ac010501i
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Electrospray ionization mass spectrometry is a valuable tool in the identification and quantification of drug metabolites in biological fluids. However, there are many instances where matrix components present in these fluids interfere with analyte detection and prevent the acquisition of accurate or complete results. In some instances, the matrix can suppress ionization to such an extent that analytes are completely undetectable by MS. In this work, we investigate how ionization and ion-transfer efficiencies are affected by drastically reducing the flow into the MS. A postcolumn concentric flow-splitting device was constructed to allow the measurement of analyte signal and ionization suppression across a range of flow rates (0.1-200 muL/min). Using this device, the effects of flow rate on signal intensity and ionization suppression were measured in analytical experiments that included flow injection analysis MS, postcolumn addition LC-MS, and on-line LC-MS analysis of metabolites generated from rat liver microsomes. The device used to deliver 0.1 muL/min flows is referred to as a nanosplitter because it achieved high split ratios (2000: 1), producing flow rates comparable to those observed in nanoelectrospray. The nanosplitter maintained chromatographic integrity with high fidelity and allowed the direct comparison of analyte signal across a range of flow rates (0.1-200 muL/min). A significant improvement in concentration and mass sensitivity as well as a reduction in signal suppression is observed when the performance at 200 versus 0.1 muL/min flow rate is compared. Using this specially designed concentric splitting device, the advantages of ultralow flow ESI were easily exploited for applications employing large bore chromatography.
引用
收藏
页码:5635 / 5644
页数:10
相关论文
共 32 条
  • [11] A MICROSCALE ELECTROSPRAY INTERFACE FOR ONLINE, CAPILLARY LIQUID-CHROMATOGRAPHY TANDEM MASS-SPECTROMETRY OF COMPLEX PEPTIDE MIXTURES
    DAVIS, MT
    STAHL, DC
    HEFTA, SA
    LEE, TD
    [J]. ANALYTICAL CHEMISTRY, 1995, 67 (24) : 4549 - 4556
  • [12] A predictive model for matrix and analyte effects in electrospray ionization of singly-charged ionic analytes
    Enke, CG
    [J]. ANALYTICAL CHEMISTRY, 1997, 69 (23) : 4885 - 4893
  • [13] FACTORS AFFECTING ELECTROSPRAY-IONIZATION OF EFFLUENTS CONTAINING TRIFLUOROACETIC-ACID FOR HIGH-PERFORMANCE LIQUID CHROMATOGRAPHY/MASS SPECTROMETRY
    ESHRAGHI, J
    CHOWDHURY, SK
    [J]. ANALYTICAL CHEMISTRY, 1993, 65 (23) : 3528 - 3533
  • [14] Determination of carnitine and acylcarnitines in biological samples by capillary electrophoresis-mass spectrometry
    Heinig, K
    Henion, J
    [J]. JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 1999, 735 (02): : 171 - 188
  • [15] Hsieh F, 1999, RAPID COMMUN MASS SP, V13, P67, DOI 10.1002/(SICI)1097-0231(19990115)13:1<67::AID-RCM453>3.0.CO
  • [16] 2-F
  • [17] Comparison of plasma sample purification by manual liquid-liquid extraction, automated 96-well liquid-liquid extraction and automated 96-well solid-phase extraction for analysis by highperformance liquid chromatography with tandem mass spectrometry
    Jemal, M
    Teitz, D
    Ouyang, Z
    Khan, S
    [J]. JOURNAL OF CHROMATOGRAPHY B, 1999, 732 (02): : 501 - 508
  • [18] Nanoelectrospray -: More than just a minimized-flow electrospray ionization source
    Juraschek, R
    Dülcks, T
    Karas, M
    [J]. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 1999, 10 (04) : 300 - 308
  • [19] Mechanistic investigation of ionization suppression in electrospray ionization
    King, R
    Bonfiglio, R
    Fernandez-Metzler, C
    Miller-Stein, C
    Olah, T
    [J]. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2000, 11 (11) : 942 - 950
  • [20] Koudriakova T, 1998, DRUG METAB DISPOS, V26, P552