Fluorogen activating proteins in flow cytometry for the study of surface molecules and receptors

被引:18
作者
Saunders, Matthew J. [1 ]
Szent-Gyorgyi, Christopher [1 ]
Fisher, Gregory W. [1 ]
Jarvik, Jonathan W. [1 ,2 ]
Bruchez, Marcel P. [1 ,2 ,3 ]
Waggoner, Alan S. [1 ,2 ]
机构
[1] Carnegie Mellon Univ, Mol Biosensor & Imaging Ctr, Pittsburgh, PA 15213 USA
[2] Carnegie Mellon Univ, Dept Biol Sci, Pittsburgh, PA 15213 USA
[3] Carnegie Mellon Univ, Dept Chem, Pittsburgh, PA 15213 USA
关键词
Fluorogen activating protein (FAP); Fluorescence; Receptor internalization; Fluorescence amplification; Fluorescent proteins; Dose-response; GREEN FLUORESCENT PROTEIN; COUPLED RECEPTORS; SACCHAROMYCES-CEREVISIAE; LIVING CELLS; MEMBRANE; DISPLAY; TRAFFICKING; TECHNOLOGY; ANTIBODIES; DYES;
D O I
10.1016/j.ymeth.2012.02.003
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The use of fluorescent proteins, particularly when genetically fused to proteins of biological interest, have greatly advanced many flow cytometry research applications. However, there remains a major limitation to this methodology in that only total cellular fluorescence is measured. Commonly used fluorescent proteins (e.g. EGFP and its variants) are fluorescent whether the fusion protein exists on the surface or in sub-cellular compartments. A flow cytometer cannot distinguish between these separate sources of fluorescence. This can be of great concern when using flow cytometry, plate readers or microscopy to quantify cell surface receptors or other surface proteins genetically fused to fluorescent proteins. Recently developed fluorogen activating proteins (FAPs) solve many of these issues by allowing the selective visualization of only those cell surface proteins that are exposed to the extracellular milieu. FAPs are GFP-sized single chain antibodies that specifically bind to and generate fluorescence from otherwise non-fluorescent dyes ('activate the fluorogen'). Like the fluorescent proteins, FAPs can be genetically fused to proteins of interest. When exogenously added fluorogens bind FAPs, fluorescence immediately increases by as much as 20,000-fold, rendering the FAP fusion proteins highly fluorescent. Moreover, since fluorogens can be made membrane impermeant, fluorescence can be limited to only those receptors expressed on the cell surface. Using cells expressing beta-2 adrenergic receptor (beta 2AR) fused at its N-terminus to a FAP, flow cytometry based receptor internalization assays have been developed and characterized. The fluorogen/FAP system is ideally suited to the study of cell surface proteins by fluorescence and avoids drawbacks of using receptor/fluorescent protein fusions, such as internal accumulation. We also briefly comment on extending FAP-based technologies to the study of events occurring inside of the cell as well. (C) 2012 Elsevier Inc. All rights reserved.
引用
收藏
页码:308 / 317
页数:10
相关论文
共 50 条
[41]   Cell-based screening: a high throughput flow cytometry platform for identification of cell-specific targeting molecules [J].
Smith, RA ;
Giorgio, TD .
COMBINATORIAL CHEMISTRY & HIGH THROUGHPUT SCREENING, 2004, 7 (02) :141-151
[42]   Intrinsic relative activities of κ opioid agonists in activating Gα proteins and internalizing receptor: Differences between human and mouse receptors [J].
DiMattio, Kelly M. ;
Ehlert, Frederick J. ;
Liu-Chen, Lee-Yuan .
EUROPEAN JOURNAL OF PHARMACOLOGY, 2015, 761 :235-244
[43]   Nanodiscs: A Controlled Bilayer Surface for the Study of Membrane Proteins [J].
McLean, Mark A. ;
Gregory, Michael C. ;
Sligar, Stephen G. .
ANNUAL REVIEW OF BIOPHYSICS, VOL 47, 2018, 47 :107-124
[44]   Orientational averaging of dye molecules attached to proteins in Foumlrster resonance energy transfer measurements: Insights from a simulation study [J].
Allen, Lucy R. ;
Paci, Emanuele .
JOURNAL OF CHEMICAL PHYSICS, 2009, 131 (06)
[45]   Chimeric antigen receptors of HBV envelope proteins inhibit hepatitis B surface antigen secretion [J].
Wang, Yang ;
Li, Qiqi ;
Li, Cheng ;
Wang, Cong ;
Wang, Shijie ;
Yuan, Wenjie ;
Yu, Demin ;
Zhang, Ke ;
Shi, Bisheng ;
Chen, Xiaomei ;
Liu, Tiantian ;
Yuan, Zhenghong ;
Tong, Shuping ;
Nassal, Michael ;
Wen, Yu-Mei ;
Wang, Yong-Xiang .
GUT, 2024, 73 (04) :668-681
[46]   Lectin staining and flow cytometry reveals female-induced sperm acrosome reaction and surface carbohydrate reorganization [J].
Kekalainen, Jukka ;
Larma, Irma ;
Linden, Matthew ;
Evans, Jonathan P. .
SCIENTIFIC REPORTS, 2015, 5
[47]   Application of Multiparametric Flow Cytometry Panels to Study Lymphocyte Subpopulations in Tuberculin-Positive Cattle [J].
Manzo-Sandoval, Anabelle ;
Jaramillo-Meza, Laura ;
Olguin-Alor, Roxana ;
Sanchez-Torres, Luvia Enid ;
Diaz-Otero, Fernando .
VETERINARY SCIENCES, 2023, 10 (03)
[48]   Cell wall hydrolase as a surface-associated protein target for the specific detection of Lactobacillus rhamnosus using flow cytometry [J].
Marcos-Fernandez, Raquel ;
Ruiz, Lorena ;
Blanco-Miguez, Aitor ;
Margolles, Abelardo ;
Sanchez, Borja .
INNOVATIVE FOOD SCIENCE & EMERGING TECHNOLOGIES, 2020, 59
[49]   Yeast Intracellular Staining (yICS): Enabling High-Throughput, Quantitative Detection of Intracellular Proteins via Flow Cytometry for Pathway Engineering [J].
Hill, Brett D. ;
Prabhu, Ponnandy ;
Rizvi, Syed M. ;
Wen, Fei .
ACS SYNTHETIC BIOLOGY, 2020, 9 (08) :2119-2131
[50]   Detection of epitope-tagged proteins in flow cytometry: Fluorescence resonance energy transfer-based assays on beads with femtomole resolution [J].
Buranda, T ;
Lopez, GP ;
Simons, P ;
Pastuszyn, A ;
Sklar, LA .
ANALYTICAL BIOCHEMISTRY, 2001, 298 (02) :151-162