A novel electrochemical sensor based on FeS anchored reduced graphene oxide nanosheets for simultaneous determination of dopamine and acetaminophen

被引:74
作者
Liu, Xiaoya [1 ]
Shangguan, Enbo [1 ,2 ]
Li, Jing [1 ]
Ning, Sashuang [1 ]
Guo, Litan [1 ]
Li, Quanmin [1 ]
机构
[1] Henan Normal Univ, Collaborat Innovat Ctr Henan Prov Green Mfg Fine, Key Lab Green Chem Media & React, Minist Educ,Sch Chem & Chem Engn, Xinxiang 453007, Peoples R China
[2] Henan Huanyu Grp Co Ltd, Postdoctoral Res Ctr, Xinxiang 453002, Peoples R China
来源
MATERIALS SCIENCE AND ENGINEERING C-MATERIALS FOR BIOLOGICAL APPLICATIONS | 2017年 / 70卷
基金
中国博士后科学基金;
关键词
Nanosheets; Iron(II) sulfide; Reduced graphene oxide; Dopamine; Acetaminophen; GLASSY-CARBON ELECTRODE; ASCORBIC-ACID; URIC-ACID; SENSITIVE DETECTION; NANOPARTICLES; NANOCOMPOSITE; COMPOSITE; NANOTUBES; NICKEL; OXIDATION;
D O I
10.1016/j.msec.2016.09.034
中图分类号
TB3 [工程材料学]; R318.08 [生物材料学];
学科分类号
0805 ; 080501 ; 080502 ;
摘要
In this paper, FeS nanoparticles anchored on reduced graphene oxide (rGO) nanosheets are synthesized via a facile direct-precipitation method. For the first time, a novel electrochemical sensor is developed based on FeS/rGO nanosheets modified glassy carbon electrode (GCE). It has been proved that the resultant FeS/rGO/GCE sensor is very suitable for the individual and simultaneous measurement of dopamine (DA) and acetaminophen (AC) and delivers excellent anti-interference ability to ascorbic acid (AA) and uric acid (UA). Under optimum conditions with differential pulse voltammetry method, a broad linear response versus the concentrations of DA and AC has been observed in the ranges of 2.0 to 250.0 mu M and 5.0 to 300.0 mu M, respectively. The detection limits for DA and AC are 0.098 mu M and 0.18 mu M, respectively. Furthermore, the as-obtained sensor has been successfully utilized in real samples and satisfactory results have been achieved. Consequently, by virtue of its outstanding electrocatalytic activity, excellent sensitivity, and long time stability, the as-obtained FeS/rGO modified electrode can be considered as a new promising DA and AC sensor. (C) 2016 Elsevier B.V. All rights reserved.
引用
收藏
页码:628 / 636
页数:9
相关论文
共 49 条
[1]   Simultaneous electrochemical determination of dopamine and acetaminophen using multiwall carbon nanotubes modified glassy carbon electrode [J].
Alothman, Zeid Abdullah ;
Bukhari, Nausheen ;
Wabaidur, Saikh Mohammad ;
Haider, Sajjad .
SENSORS AND ACTUATORS B-CHEMICAL, 2010, 146 (01) :314-320
[2]   WO3 nanoparticles based direct electrochemical dopamine sensor in the presence of ascorbic acid [J].
Anithaa, A. C. ;
Lavanya, N. ;
Asokan, K. ;
Sekar, C. .
ELECTROCHIMICA ACTA, 2015, 167 :294-302
[3]   Investigation on the downregulation of dopamine by acetaminophen administration based on their simultaneous determination in urine [J].
Chandra, Pranjal ;
Son, Nguyen X. ;
Noh, Hui-Bog ;
Goyal, Rajendra N. ;
Shim, Yoon-Bo .
BIOSENSORS & BIOELECTRONICS, 2013, 39 (01) :139-144
[4]   Au/ZnO hybrid nanocatalysts impregnated in N-doped graphene for simultaneous determination of ascorbic acid, acetaminophen and dopamine [J].
Chen, Xianlan ;
Zhang, Guowei ;
Shi, Ling ;
Pan, Shanqing ;
Liu, Wei ;
Pan, Hiabo .
MATERIALS SCIENCE & ENGINEERING C-MATERIALS FOR BIOLOGICAL APPLICATIONS, 2016, 65 :80-89
[5]   A new Ag-nanoparticle with 4-nitro phenylcyanamide ligand: synthesis characterization and application to the detection of dibucaine, naphazoline, dopamine, and acetaminophen [J].
Chiniforoshan, Hossein ;
Tabrizi, Leila ;
Pourrahim, Nasimeh .
JOURNAL OF APPLIED ELECTROCHEMISTRY, 2015, 45 (02) :197-207
[6]   Simultaneous determination of dopamine, ascorbic acid, and uric acid using helical carbon nanotubes modified electrode [J].
Cui, Rongjing ;
Wang, Xueying ;
Zhang, Genhua ;
Wang, Chen .
SENSORS AND ACTUATORS B-CHEMICAL, 2012, 161 (01) :1139-1143
[7]   Nanocrystalline boron-doped diamond nanoelectrode arrays for ultrasensitive dopamine detection [J].
Dincer, Can ;
Ktaich, Rabih ;
Laubender, Elmar ;
Hees, J. Jakob ;
Kieninger, Jochen ;
Nebel, Christoph E. ;
Heinze, Juergen ;
Urban, Gerald A. .
ELECTROCHIMICA ACTA, 2015, 185 :101-106
[8]   Voltammetric behavior of dopamine at a glassy carbon electrode modified with NiFe2O4 magnetic nanoparticles decorated with multiwall carbon nanotubes [J].
Ensafi, Ali A. ;
Arashpour, B. ;
Rezaei, B. ;
Allafchian, Ali R. .
MATERIALS SCIENCE & ENGINEERING C-MATERIALS FOR BIOLOGICAL APPLICATIONS, 2014, 39 :78-85
[9]   A differential pulse voltammetric method for simultaneous determination of ascorbic acid, dopamine, and uric acid using poly (3-(5-chloro-2-hydroxyphenylazo)-4,5-dihydroxynaphthalene-2,7-disulfonic acid) film modified glassy carbon electrode [J].
Ensafi, Ali A. ;
Taei, M. ;
Khayamian, T. .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2009, 633 (01) :212-220
[10]   Single Molecular Functionalized Gold Nanoparticles for Hydrogen-Bonding Recognition and Colorimetric Detection of Dopamine with High Sensitivity and Selectivity [J].
Feng, Jiu-Ju ;
Guo, Han ;
Li, Yong-Fang ;
Wang, Yun-Hua ;
Chen, Wan-Yi ;
Wang, Ai-Jun .
ACS APPLIED MATERIALS & INTERFACES, 2013, 5 (04) :1226-1231