Dose escalation in image-guided, intensity-modulated radiotherapy of carcinoma prostate: Initial experience in India

被引:1
作者
Swamy, Kumara [1 ]
Narayanan, V. K. Sathiya [1 ]
Basu, Sumeet [1 ]
Maiya, Vikram [1 ]
Achari, Rimpa [1 ]
Deshpande, Shrikant [1 ]
Bhangle, Janhavi [1 ]
Gupta, Kamlesh Kumar [1 ]
Babu, Nirmal [1 ]
Pawar, Surendra [1 ]
Atre, Ashish [1 ]
Balachandra, Kashyapi [2 ]
Koppiker, C. B. [2 ]
机构
[1] Ruby Hall Clin, Ruby Hall Canc Ctr, Dept Radiat Oncol, Pune 411001, Maharashtra, India
[2] Jehangir Hosp, Dept Oncol, Pune 411001, Maharashtra, India
关键词
Dose escalation; gold seed markers; image guided intensity modulated radiotherapy; PSA; EXTERNAL-BEAM RADIOTHERAPY; CONFORMAL RADIOTHERAPY; RADIATION-THERAPY; CANCER; MARKERS; LOCALIZATION; SURVIVAL; GUIDANCE; MOTION; RISK;
D O I
10.4103/0973-1482.59909
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Background : Increasing incidence and significant stage migration from distant metastases to a localized disease, due to screening application of PSA, is taking place in carcinoma prostate. Also, role of radiotherapy is increasing in carcinoma prostate due to rapid strides in technology. Aim : The present retrospective study, evaluates escalating the dose in the treatment of localized carcinoma prostate using integration of multiple advanced techniques. Settings and Design : The settings designed are: a) use of gold seed internal fiducial markers: b) clinical application of emerging Megavoltage Cone Beam Computed Tomography (MVCBCT) technology for Image Guided Radiotherapy (IGRT); c) Intensity Modulated Radiotherapy (IMRT); d) adopting biochemical method for follow-up. Methods and Material : Twelve consecutive, biopsy proven localized cancer of prostate patients, treated with dose escalation IMRT& IGRT protocol between August 2006 and January 2008, were analyzed. Gold seed markers in prostate were used for daily localization with MVCBCT or Electronic Portal Imaging (EPI). All patients underwent clinical and biochemical follow-up. Statistical Analysis& Results : Planned dose of 7740 cGy was delivered in 10 out of 12 patients (83). While one patient had migration of maximum of 3 mm, two others had 1 mm migration of one seed during course of treatment. One patient (8) developed Grade II proctitis at 12th month. During the mean follow-up duration of 12.2 months, 92 (11/12) had biochemical control within 3 months of treatment. Conclusions : IGRT technique using MVCBCT for implanted fiducial gold seed localization was feasible for IMRT dose escalation in carcinoma prostate with excellent results.
引用
收藏
页码:277 / 283
页数:7
相关论文
共 24 条
  • [1] Increased risk of biochemical and local failure in patients with distended rectum on the planning CT for prostate cancer radiotherapy
    De Crevoisier, R
    Tucker, SL
    Dong, L
    Mohan, R
    Cheung, R
    Cox, JD
    Kuban, DA
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2005, 62 (04): : 965 - 973
  • [2] Escalated-dose versus standard-dose conformal radiotherapy in prostate cancer: first results from the MRC RT01 randomised controlled trial
    Dearnaley, David P.
    Sydes, Matthew R.
    Graham, John D.
    Aird, Edwin G.
    Bottomley, David
    Cowan, Richard A.
    Huddart, Robert A.
    Jose, Chakiath C.
    Matthews, John H. L.
    Millar, Jeremy
    Moore, A. Rollo
    Morgan, Rachel C.
    Russell, J. Martin
    Scrase, Christopher D.
    Stephens, Richard J.
    Syndikus, Isabel
    Parmar, Mahesh K. B.
    [J]. LANCET ONCOLOGY, 2007, 8 (06) : 475 - 487
  • [3] Comparison of radiation side-effects of conformal and conventional radiotherapy in prostate cancer: a randomised trial
    Dearnaley, DP
    Khoo, VS
    Norman, AR
    Meyer, L
    Nahum, A
    Tait, D
    Yarnold, J
    Horwich, A
    [J]. LANCET, 1999, 353 (9149) : 267 - 272
  • [4] Clinical feasibility study for the use of implanted gold seeds in the prostate as reliable positioning markers during megavoltage irradiation
    Dehnad, H
    Nederveen, AJ
    van der Heide, UA
    van Moorselaar, RJA
    Hofman, P
    Lagendijk, JJW
    [J]. RADIOTHERAPY AND ONCOLOGY, 2003, 67 (03) : 295 - 302
  • [5] Feigenberg SJ, 2005, PRACTICAL ESSENTIALS
  • [6] A performance comparison of flat-panel imager-based MV and kV cone-beam CT
    Groh, BA
    Siewerdsen, JH
    Drake, DG
    Wong, JW
    Jaffray, DA
    [J]. MEDICAL PHYSICS, 2002, 29 (06) : 967 - 975
  • [7] Hanks GE, 1999, CANCER J, V5, P152
  • [8] Kannan V, 2005, J Cancer Res Ther, V1, P34
  • [9] Intrafraction motion of the prostate during external-beam radiation therapy: Analysis of 427 patients with implanted fiducial markers
    Kotte, Alexis N. T. J.
    Hofman, Pieter
    Lagendijk, Jan J. W.
    van Vulpen, Marco
    van der Heide, Uulke A.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2007, 69 (02): : 419 - 425
  • [10] Effect of increasing radiation doses on local and distant failures in patients with localized prostate cancer
    Kupelian, Patrick A.
    Ciezki, Jay
    Reddy, Chandana A.
    Klein, Eric A.