Automation of gated tomographic left ventricular ejection fraction

被引:81
作者
Nichols, K
DePuey, EG
Rozanski, A
机构
[1] ST LUKES ROOSEVELT HOSP,DEPT RADIOL,NEW YORK,NY 10025
[2] COLUMBIA UNIV,COLL PHYS & SURG,NEW YORK,NY
关键词
radionuclide imaging; gated single-photon emission computed tomography; ejection fraction;
D O I
10.1016/S1071-3581(96)90057-4
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background The feasibility of determining left ventricular (LV) ejection fraction (EF) from Tc-99m-labeled sestamibi gated tomography (GSPECT) is well established, To improve precision of measurement, rules used by observers in processing tomograms were encoded for automation. Methods and Results, LV centers were estimated from activity centroids of time-difference images exceeding 50% of maximum counts, End diastole and end systole were defined by time-varying maximum count extremes, Endocardial borders were generated by fitting maximum locations with fifth-order two-dimensional harmonics, searching inward to predetermined thresholds, and reconciling endocardial with valve plane points, Regression analysis of GSPECT EF yielded r = 0.87 versus equilibrium gated blood pool in 75 patients and r = 0.87 versus gated first pass in 65 patients, GSPECT EF interobserver variability was r = 0.92 and intraobserver automatic versus manual linear correlation was r = 0.94. A subgroup of 25 studies was analyzed by six independent observers, for whom EF agreement with the core laboratory ranged from r = 0.93 to r = 0.96, Experienced observers judged it necessary to alter end-diastolic or end-systolic frames in 7% of patients, endocardial borders in 14%, and LV centers in 28%. Conclusion. Results of automated GSPECT LV EF correlated well with those of manual GSPECT and gated first-pass and equilibrium blood pool values and were highly reproducible.
引用
收藏
页码:475 / 482
页数:8
相关论文
共 22 条
[1]  
CHRISTIAN PE, 1985, J NUCL MED, V26, P775
[2]  
COOKE CD, 1994, J NUCL MED, V35, P1185
[3]  
DEPUEY EG, 1995, J NUCL MED, V36, P569
[4]  
DEPUEY EG, 1993, J NUCL MED, V34, P1871
[5]   Simultaneous transmission emission myocardial perfusion tomography diagnostic accuracy of attenuatian-corrected Tc-99m-sestamibi single-photon emission computed tomography [J].
Ficaro, EP ;
Fessler, JA ;
Shreve, PD ;
Kritzman, JN ;
Rose, PA ;
Corbett, JR .
CIRCULATION, 1996, 93 (03) :463-473
[6]   TECHNICAL ASPECTS OF MYOCARDIAL SPECT IMAGING WITH TC-99M SESTAMIBI [J].
GARCIA, EV ;
COOKE, CD ;
VANTRAIN, KF ;
FOLKS, R ;
PEIFER, J ;
DEPUEY, EG ;
MADDAHI, J ;
ALAZRAKI, N ;
GALT, J ;
EZQUERRA, N ;
ZIFFER, J ;
AREEDA, J ;
BERMAN, DS .
AMERICAN JOURNAL OF CARDIOLOGY, 1990, 66 (13) :E23-E31
[7]  
GERMANO G, 1995, J NUCL MED, V36, P2138
[8]  
Gradel Christoph, 1996, Journal of the American College of Cardiology, V27, p241A
[9]   A CONE-BEAM FILTERED BACKPROJECTION RECONSTRUCTION ALGORITHM FOR CARDIAC SINGLE PHOTON-EMISSION COMPUTED-TOMOGRAPHY [J].
GULLBERG, GT ;
ZENG, GL .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 1992, 11 (01) :91-101
[10]  
HOFFMAN EJ, 1979, J COMPUT ASSIST TOMO, V5, P391