Automated 3D Analysis of Multislice Computed Tomography to Define the Line of Perpendicularity of the Aortic Annulus and of the Implanted Valve: Benefit on Planning Transcatheter Aortic Valve Replacement

被引:2
作者
Samin, Mariam [1 ]
Juthier, Francis [4 ,5 ]
Van Belle, Camille [4 ,5 ]
Agostoni, Pierfrancesco [1 ]
Kluin, Jolanda [2 ]
Stella, Pieter R. [1 ]
Ramjankhan, Faiez [2 ]
Budde, Ricardo P. J. [3 ]
Sieswerda, Gertjan [1 ]
Algeri, Emanuela [4 ,5 ]
Elkalioubie, Ahmed [4 ,5 ]
Belkacemi, Anouar [1 ]
Bertrand, Michel E. [4 ,5 ]
Doevendans, Pieter A. [1 ]
Van Belle, Eric [4 ,5 ]
机构
[1] Univ Med Ctr, Dept Cardiol Thorax Surg & Radiol, Utrecht, Netherlands
[2] Univ Med Ctr, Dept Thorax Surg, Utrecht, Netherlands
[3] Univ Med Ctr, Dept Radiol, Utrecht, Netherlands
[4] Univ Hosp, Dept Cardiol, Lille, France
[5] Univ Hosp, EA 2693, Lille, France
关键词
valvular heart disease; aortic stenosis; MDCT; TAVR; REGURGITATION; ROOT;
D O I
10.1002/ccd.24947
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
AimsWe aimed to determine whether preprocedural analysis of multislice computed tomography (MDCT) scan could accurately predict the line of perpendicularity (LP) of the aortic annulus and corresponding C-arm angulations required for prosthesis delivery. Methods and ResultsA 3D analysis of preprocedural MDCT dedicated to define the LP of the aortic annulus was performed in 60 consecutive patients referred for transcatheter aortic valve replacement (TAVR). In 24 patients, the analysis was performed retrospectively to evaluate reproducibility. In 11 patients of this cohort, additional fluoroscopy and MDCT were performed postprocedure to compare the LP of the aortic annulus and the LP of the implanted bioprosthesis. In 36 patients, the analysis was performed prospectively and the results were available at the time of the procedure. In those 36 patients, the postprocedure fluoroscopy-defined LP of the implanted bioprosthesis was used to validate the LP of the aortic annulus as predicted by MDCT. Intraobserver and interobserver reproducibility of the 3D analysis of MDCT to define the LP of the aortic annulus ( = 1 and 0.94, respectively) and of the bioprosthesis (= 1 and 1, respectively) were excellent. Comparison between the LP of the aortic annulus and the LP of the bioprosthesis showed that the two LPs were virtually identical, demonstrating both self-centering of the device during implantation and the possibility to use the LP of the implanted bioprosthesis as a surrogate of the LP of the aortic annulus. In the prospective cohort, the ability of MDCT analysis to predict the LP of the aortic annulus was very good (accuracy = 94% and = 0.89). ConclusionAutomated 3D analysis of preimplantation MDCT accurately predicts the LP of the aortic annulus and the corresponding C-arm position required for TAVR.(c) 2013 Wiley Periodicals, Inc.
引用
收藏
页码:E119 / E127
页数:9
相关论文
共 9 条
[1]   Early experience with percutaneous transcatheter implantation of heart valve prosthesis for the treatment of end-stage inoperable patients with calcific aortic stenosis [J].
Cribier, A ;
Eltchaninoff, H ;
Tron, C ;
Bauer, F ;
Agatiello, C ;
Sebagh, L ;
Bash, A ;
Nusimovici, D ;
Litzler, PY ;
Bessou, JP ;
Leon, MB .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2004, 43 (04) :698-703
[2]   Multislice Computed Tomography for Prediction of Optimal Angiographic Deployment Projections During Transcatheter Aortic Valve Implantation [J].
Gurvitch, Ronen ;
Wood, David A. ;
Leipsic, Jonathon ;
Tay, Edgar ;
Johnson, Mark ;
Ye, Jian ;
Nietlispach, Fabian ;
Wijesinghe, Namal ;
Cheung, Anson ;
Webb, John G. .
JACC-CARDIOVASCULAR INTERVENTIONS, 2010, 3 (11) :1157-1165
[3]   Measurement of observer agreement [J].
Kundel, HL ;
Polansky, M .
RADIOLOGY, 2003, 228 (02) :303-308
[4]   Pre-Procedural Imaging of Aortic Root Orientation and Dimensions Comparison Between X-Ray Angiographic Planar Imaging and 3-Dimensional Multidetector Row Computed Tomography [J].
Kurra, Vikram ;
Kapadia, Samir R. ;
Tuzcu, E. Murat ;
Halliburton, Sandra S. ;
Svensson, Lars ;
Roselli, Eric E. ;
Schoenhagen, Paul .
JACC-CARDIOVASCULAR INTERVENTIONS, 2010, 3 (01) :105-113
[5]  
Rivard AL, 2009, J HEART VALVE DIS, V18, P662
[6]   A prospective "oversizing'' strategy of the Edwards SAPIEN bioprosthesis: Results and impact on aortic regurgitation [J].
Samim, Mariam ;
Stella, Pieter R. ;
Agostoni, Pierfrancesco ;
Kluin, Jolanda ;
Ramjankhan, Faiz ;
Sieswerda, Gertjan ;
Budde, Ricardo ;
van der Linden, Marijke ;
Juthier, Francis ;
Banfi, Carlo ;
Hurt, Christopher ;
Samim, Morsal ;
Hillaert, Marieke ;
van Herwerden, Lex ;
Bertrand, Michel E. ;
Doevendans, Pieter A. M. ;
Van Belle, Eric .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2013, 145 (02) :398-405
[7]   Transcatheter aortic implantation of the Edwards-SAPIEN bioprosthesis: Insights on early benefit of TAVI on mitral regurgitation [J].
Samim, Mariam ;
Stella, Pieter R. ;
Agostoni, Pierfrancesco ;
Kluin, Jolanda ;
Ramjankhan, Faiez ;
Sieswerda, Gertjan ;
Budde, Riccardo ;
van der Linden, Marijke ;
Samim, Morsal ;
Hillaert, Marieke ;
van Herwerden, Lex ;
Doevendans, Pieter A. M. ;
van Belle, Eric .
INTERNATIONAL JOURNAL OF CARDIOLOGY, 2011, 152 (01) :124-126
[8]   Transcatheter versus Surgical Aortic-Valve Replacement in High-Risk Patients [J].
Smith, Craig R. ;
Leon, Martin B. ;
Mack, Michael J. ;
Miller, Craig ;
Moses, Jeffrey W. ;
Svensson, Lars G. ;
Tuzcu, E. Murat ;
Webb, John G. ;
Fontana, Gregory P. ;
Makkar, Raj R. ;
Williams, Mathew ;
Dewey, Todd ;
Kapadia, Samir ;
Babaliaros, Vasilis ;
Thourani, Vinod H. ;
Corso, Paul ;
Pichard, Augusto D. ;
Bavaria, Joseph E. ;
Herrmann, Howard C. ;
Akin, Jodi J. ;
Anderson, William N. ;
Wang, Duolao ;
Pocock, Stuart J. .
NEW ENGLAND JOURNAL OF MEDICINE, 2011, 364 (23) :2187-2198
[9]   Transcatheter Aortic Valve Replacement Malposition and Embolization: Innovation Brings Solutions Also New Challenges [J].
Tuzcu, E. Murat .
CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2008, 72 (04) :579-580