A new technique for islanding detection using voltage phase angle of inverter-based DGs

被引:47
作者
Pourbabak, Hajir [1 ]
Kazemi, Ahad [1 ]
机构
[1] Iran Univ Sci & Technol, Dept Elect Engn, Ctr Excellence Power Syst Automat & Operat, Tehran, Iran
关键词
Islanding detection; Distributed generation (DG); Active methods; Voltage angle; Power mismatch; Inverter-based distributed generators; PERFORMANCE; PROTECTION;
D O I
10.1016/j.ijepes.2013.12.008
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
In this paper, a new method is studied for the islanding detection of an inverter based distribution generation. The use of parameters at PCC (such as deviation of the voltage and frequency) as a feedback has been considered by researchers. The variation of voltage angle is used as a feedback in the proposed method. After an islanding occurrence the variation of voltage phase angle can change the references of active and reactive powers. The power variations cause the voltage and frequency deviations as detection parameters. The performance of islanding detection of the proposed method is investigated under the IEEE UL 1741 for the worst-case. The simulation results show that the adverse effects of this method are negligible and non-detection zone of the proposed method is small. Also, this method has no significant effects on the power quality and system normal operation mode. In addition, the results of tests for multiple DGs are suitable and there is not any significant interference between DGs in the normal operation mode. (C) 2013 Elsevier Ltd. All rights reserved.
引用
收藏
页码:198 / 205
页数:8
相关论文
共 25 条
[1]   Islanding Detection for Inverter-Based DG Coupled With Frequency-Dependent Static Loads [J].
Alaboudy, Ali H. Kasem ;
Zeineldin, H. H. .
IEEE TRANSACTIONS ON POWER DELIVERY, 2011, 26 (02) :1053-1063
[2]  
[Anonymous], 2000, 9292000 IEEE
[3]  
[Anonymous], 2005, IEEE Std 1547.1-2005, DOI [10.1109/IEEESTD.2013.6673990, 10.1109/IEEESTD.2005.96469, DOI 10.1109/IEEESTD.2005.96469]
[4]  
[Anonymous], 2001, 1741 UL STD
[5]   Nondetection Zone Assessment of an Active Islanding Detection Method and its Experimental Evaluation [J].
Bahrani, Behrooz ;
Karimi, Houshang ;
Iravani, Reza .
IEEE TRANSACTIONS ON POWER DELIVERY, 2011, 26 (02) :517-525
[6]  
Bower W., 2002, Evaluation of islanding detection methods for utility-interactive inverters in photovoltaic systems
[7]   Active islanding detection method for inverter-based distribution generation power system [J].
Chiang, Wen-Jung ;
Jou, Hurng-Liahng ;
Wu, Jinn-Chang .
INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2012, 42 (01) :158-166
[8]   A hybrid time-frequency approach based fuzzy logic system for power island detection in grid connected distributed generation [J].
Dash, P. K. ;
Padhee, Malhar ;
Panigrahi, T. K. .
INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2012, 42 (01) :453-464
[9]   Islanding detection for inverter-based DG coupled with using an adaptive neuro-fuzzy inference system [J].
Hashemi, Farid ;
Ghadimi, Noradin ;
Sobhani, Behrooz .
INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2013, 45 (01) :443-455
[10]   Enhancement of islanding-detection of distributed generation systems via wavelet transform-based approaches [J].
Hsieh, Cheng-Tao ;
Lin, Jeu-Min ;
Huang, Shyh-Jier .
INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2008, 30 (10) :575-580